Quantitative susceptibility mapping (QSM) minimizes interference from cellular pathology in R2* estimation of liver iron concentration. Issue 4 (22nd March 2018)
- Record Type:
- Journal Article
- Title:
- Quantitative susceptibility mapping (QSM) minimizes interference from cellular pathology in R2* estimation of liver iron concentration. Issue 4 (22nd March 2018)
- Main Title:
- Quantitative susceptibility mapping (QSM) minimizes interference from cellular pathology in R2* estimation of liver iron concentration
- Authors:
- Li, Jianqi
Lin, Huimin
Liu, Tian
Zhang, Zhuwei
Prince, Martin R.
Gillen, Kelly
Yan, Xu
Song, Qi
Hua, Ting
Zhao, Xiance
Zhang, Miao
Zhao, Yu
Li, Gaiying
Tang, Guangyu
Yang, Guang
Brittenham, Gary M.
Wang, Yi - Abstract:
- Abstract : Background: A challenge for R2 and R2* methods in measuring liver iron concentration (LIC) is that fibrosis, fat, and other hepatic cellular pathology contribute to R2 and R2* and interfere with LIC estimation. Purpose: To examine the interfering effects of fibrosis, fat, and other lesions on R2* LIC estimation and to use quantitative susceptibility mapping (QSM) to reduce these distortions. Study Type: Prospective. Phantoms, Subjects: Water phantoms with various concentrations of gadolinium (Gd), collagen (Cl, modeling fibrosis), and fat; nine healthy controls with no known hepatic disease, nine patients with known or suspected hepatic iron overload, and nine patients with focal liver lesions. Field Strength/Sequence: The phantoms and human subjects were imaged using a 3D multiecho gradient‐echo on clinical 1.5T and 3T MRI systems. Assessment: QSM and R2* images were postprocessed from the same gradient‐echo data. Fat contributions to susceptibility and R2* were corrected in signal models for LIC estimation. Statistical Tests: Polynomial regression analyses were performed to examine relations among susceptibility, R2* and true [Gd] and [Cl] in phantoms, and among susceptibility and R2* in patient livers. Results: In phantoms, R2* had a strong nonlinear dependency on [Cl], [fat], and [Gd], while susceptibility was linearly dependent (R 2 > 0.98). In patients, R2* was highly sensitive to liver pathological changes, including fat, fibrosis, and tumors, while QSMAbstract : Background: A challenge for R2 and R2* methods in measuring liver iron concentration (LIC) is that fibrosis, fat, and other hepatic cellular pathology contribute to R2 and R2* and interfere with LIC estimation. Purpose: To examine the interfering effects of fibrosis, fat, and other lesions on R2* LIC estimation and to use quantitative susceptibility mapping (QSM) to reduce these distortions. Study Type: Prospective. Phantoms, Subjects: Water phantoms with various concentrations of gadolinium (Gd), collagen (Cl, modeling fibrosis), and fat; nine healthy controls with no known hepatic disease, nine patients with known or suspected hepatic iron overload, and nine patients with focal liver lesions. Field Strength/Sequence: The phantoms and human subjects were imaged using a 3D multiecho gradient‐echo on clinical 1.5T and 3T MRI systems. Assessment: QSM and R2* images were postprocessed from the same gradient‐echo data. Fat contributions to susceptibility and R2* were corrected in signal models for LIC estimation. Statistical Tests: Polynomial regression analyses were performed to examine relations among susceptibility, R2* and true [Gd] and [Cl] in phantoms, and among susceptibility and R2* in patient livers. Results: In phantoms, R2* had a strong nonlinear dependency on [Cl], [fat], and [Gd], while susceptibility was linearly dependent (R 2 > 0.98). In patients, R2* was highly sensitive to liver pathological changes, including fat, fibrosis, and tumors, while QSM was relatively insensitive to these abnormalities ( P = 0.015). With moderate iron overload, liver susceptibility and R2* were not linearly correlated over a common R2* range [0, 100] sec −1 ( P = 0.35). Data Conclusion: R2* estimation of LIC is prone to substantial nonlinear interference from fat, fibrosis, and other lesions. QSM processing of the same gradient echo MRI data can effectively minimize the effects of cellular pathology. Level of Evidence : 1 Technical Efficacy : Stage 1 J. Magn. Reson. Imaging 2018;48:1069–1079. … (more)
- Is Part Of:
- Journal of magnetic resonance imaging. Volume 48:Issue 4(2018)
- Journal:
- Journal of magnetic resonance imaging
- Issue:
- Volume 48:Issue 4(2018)
- Issue Display:
- Volume 48, Issue 4 (2018)
- Year:
- 2018
- Volume:
- 48
- Issue:
- 4
- Issue Sort Value:
- 2018-0048-0004-0000
- Page Start:
- 1069
- Page End:
- 1079
- Publication Date:
- 2018-03-22
- Subjects:
- quantitative susceptibility mapping -- QSM -- liver iron concentration -- magnetic susceptibility -- cellularity
Magnetic resonance imaging -- Periodicals
616 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2586 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/jmri.26019 ↗
- Languages:
- English
- ISSNs:
- 1053-1807
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5010.791000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 7993.xml