Conceptual design and analysis of a novel process for hydrogen liquefaction assisted by absorption precooling system. (20th December 2018)
- Record Type:
- Journal Article
- Title:
- Conceptual design and analysis of a novel process for hydrogen liquefaction assisted by absorption precooling system. (20th December 2018)
- Main Title:
- Conceptual design and analysis of a novel process for hydrogen liquefaction assisted by absorption precooling system
- Authors:
- Aasadnia, Majid
Mehrpooya, Mehdi - Abstract:
- Abstract: Hydrogen liquefaction processes have effective function in the hydrogen supply chain. However low efficiency and high liquefaction costs are still the most important concerns about the liquefaction plants. In this study a new configuration for a hydrogen liquefier process is proposed and energy-exergy analyzed. The production rate of the liquid hydrogen ( L H 2 ) is 90 tons per day that can supply the required L H 2 of at least 90 k-180 k hydrogen vehicles in an urban area that results in the reduction of pollutions caused by carbon dioxide emission. The process is simulated in Aspen HYSYS simulator. In addition, it is optimized thorough a trial and error approach that is a functional and simple method of complicated systems analysis. The process includes a mixed refrigerant (MR) refrigeration cycle that precools feed gas hydrogen from 25 °C temperature to − 199.9 °C temperature. A new MR is used in a cascade Joule-Brayton cycle that deep-cools the low-temperature gaseous hydrogen from − 199.9 °C temperature to − 252.2 °C temperature in the cryogenic section of the plant. The novel process involves also an absorption refrigeration system (ARS) that cools some hydrogen streams in the precooling and cryogenic sections of the process. The consumed energy per kilogram of produced L H 2 is achieved as 6.47 k W h . This quantity is 2.89 k W h in the ideal conditions. The exergy efficiency of the plant is evaluated to be 45.5% that is significantly more than the exergyAbstract: Hydrogen liquefaction processes have effective function in the hydrogen supply chain. However low efficiency and high liquefaction costs are still the most important concerns about the liquefaction plants. In this study a new configuration for a hydrogen liquefier process is proposed and energy-exergy analyzed. The production rate of the liquid hydrogen ( L H 2 ) is 90 tons per day that can supply the required L H 2 of at least 90 k-180 k hydrogen vehicles in an urban area that results in the reduction of pollutions caused by carbon dioxide emission. The process is simulated in Aspen HYSYS simulator. In addition, it is optimized thorough a trial and error approach that is a functional and simple method of complicated systems analysis. The process includes a mixed refrigerant (MR) refrigeration cycle that precools feed gas hydrogen from 25 °C temperature to − 199.9 °C temperature. A new MR is used in a cascade Joule-Brayton cycle that deep-cools the low-temperature gaseous hydrogen from − 199.9 °C temperature to − 252.2 °C temperature in the cryogenic section of the plant. The novel process involves also an absorption refrigeration system (ARS) that cools some hydrogen streams in the precooling and cryogenic sections of the process. The consumed energy per kilogram of produced L H 2 is achieved as 6.47 k W h . This quantity is 2.89 k W h in the ideal conditions. The exergy efficiency of the plant is evaluated to be 45.5% that is significantly more than the exergy efficiency of the in operating hydrogen liquefiers in the world. The energy analysis reveals that the coefficient of performance (COP) of the overall system is 0.2034. The achieved COP is a higher amount in compare to the other similar processes. A sensitivity analysis is done to show the effect of the various operation conditions of the process on the features of the plant. Accordingly, the optimum mass flow of the ARS is determined as 207 k g / s for the proposed configuration. As well as, the effect of the change in the temperature approach of the heat exchangers and the changes in the adiabatic efficiency of the compressors and expanders on the SEC, COP, and the exergy efficiency of the overall plant is discussed. Furthermore, financial analysis of the plant estimates the capital expenditures (CAPEX), energy expenditures (EEX), and operational and maintenance expenditures (OMEX) as 25413 € 2000, 7370 € 2000, and 2033 € 2000 respectively. These can be specially improved be improving of the exergy efficiency of the plant. The results implicates that the proposed configuration has better performance indicators than the in-service liquefiers. Therefore, LHL plant manufacturer can be considered it in the design and development of new plants. As well as, researchers may utilize its operating conditions to improve the proposed processes. Graphical abstract: Highlights: A novel hydrogen liquefaction process is introduced and analyzed. Mixed refrigerant (MR) system and an solar absorption refrigeration cycle are used. The specific energy consumption (SEC) of the process is 6.47 k W h / k g L H 2 . … (more)
- Is Part Of:
- Journal of cleaner production. Volume 205(2018)
- Journal:
- Journal of cleaner production
- Issue:
- Volume 205(2018)
- Issue Display:
- Volume 205, Issue 2018 (2018)
- Year:
- 2018
- Volume:
- 205
- Issue:
- 2018
- Issue Sort Value:
- 2018-0205-2018-0000
- Page Start:
- 565
- Page End:
- 588
- Publication Date:
- 2018-12-20
- Subjects:
- Liquid hydrogen -- Hydrogen liquefier -- Large-scale hydrogen liquefaction -- Mixed-refrigerant -- Cascade refrigeration -- Hybrid refrigeration
Factory and trade waste -- Management -- Periodicals
Manufactures -- Environmental aspects -- Periodicals
Déchets industriels -- Gestion -- Périodiques
Usines -- Aspect de l'environnement -- Périodiques
628.5 - Journal URLs:
- http://www.sciencedirect.com/science/journal/09596526 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.jclepro.2018.09.001 ↗
- Languages:
- English
- ISSNs:
- 0959-6526
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4958.369720
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 7961.xml