Reducing signal‐to‐noise ratio degradation due to coil coupling in a receiver array for 35Cl MRI at 9.4 T: A comparison of matching and decoupling strategies. Issue 2 (5th August 2018)
- Record Type:
- Journal Article
- Title:
- Reducing signal‐to‐noise ratio degradation due to coil coupling in a receiver array for 35Cl MRI at 9.4 T: A comparison of matching and decoupling strategies. Issue 2 (5th August 2018)
- Main Title:
- Reducing signal‐to‐noise ratio degradation due to coil coupling in a receiver array for 35Cl MRI at 9.4 T: A comparison of matching and decoupling strategies
- Authors:
- Malzacher, Matthias
Hu, Ruomin
Chacon‐Caldera, Jorge
Schad, Lothar R. - Abstract:
- Abstract: Next to conventional magnetic resonance imaging (MRI), which utilizes hydrogen nuclei, other nuclei, so‐called X‐nuclei, are of increasing interest since they can provide additional diagnostic information. However, X‐nuclei MRI is challenging due to the lower Signal‐to‐Noise Ratio (SNR) compared to 1 H ( 35 Cl provides approximately 200 000 times lower SNR than 1 H). In order to compete with this challenge, the use of high‐field strengths and optimized hardware is crucial. In this work, a transmit‐only receive‐only (TORO) system for 35 Cl MRI at a preclinical 9.4 T scanner is presented, composed of a volumetric birdcage coil and a 3 channel Rx array. SNR degradation despite preamplifier decoupling can no longer be neglected since the resonance frequency of 35 Cl is low. This paper will prove the SNR degradation due to the coil coupling of the receiver coils for this setup and evaluate three different approaches to mitigate the SNR degradation. The performance of the different approaches is evaluated via single channel and combined SNR maps using phantom measurements. Finally, the SNR maps acquired with the Rx array are compared to the SNR map acquired using the Birdcage coil as a reference.
- Is Part Of:
- Concepts in magnetic resonance. Volume 48B:Issue 2(2018)
- Journal:
- Concepts in magnetic resonance
- Issue:
- Volume 48B:Issue 2(2018)
- Issue Display:
- Volume 48B, Issue 2 (2018)
- Year:
- 2018
- Volume:
- 48B
- Issue:
- 2
- Issue Sort Value:
- 2018-NaN-0002-0000
- Page Start:
- n/a
- Page End:
- n/a
- Publication Date:
- 2018-08-05
- Subjects:
- coil coupling -- RF coils -- X‐nuclei MRI
Magnetic resonance -- Periodicals
Nuclear magnetic resonance -- Periodicals
Biomedical engineering -- Periodicals
Magnetic Resonance Spectroscopy -- Periodicals
538.36 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1552-504X ↗
https://www.hindawi.com/journals/cmrb/ ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/cmr.b.21383 ↗
- Languages:
- English
- ISSNs:
- 1552-5031
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3399.413430
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 7937.xml