Antera 3D capabilities for pore measurements. Issue 4 (29th April 2018)
- Record Type:
- Journal Article
- Title:
- Antera 3D capabilities for pore measurements. Issue 4 (29th April 2018)
- Main Title:
- Antera 3D capabilities for pore measurements
- Authors:
- Messaraa, C.
Metois, A.
Walsh, M.
Flynn, J.
Doyle, L.
Robertson, N.
Mansfield, A.
O'Connor, C.
Mavon, A. - Abstract:
- Abstract: Background: The cause of enlarged pores remains obscure but still remains of concern for women. To complement subjective methods, bioengineered methods are needed for quantification of pores visibility following treatments. The study objective was to demonstrate the suitability of pore measurements from the Antera 3D. Material and methods: Pore measurements were collected on 22 female volunteers aged 18‐65 years with the Antera 3D, the DermaTOP and image analysis on photographs. Additionally, 4 raters graded pore size on photographs on a scale 0‐5. Repeatability of Antera 3D parameters was ascertained and the benefit of a pore minimizer product on the cheek was assessed on a sub panel of seven female volunteers. Results: Pore parameters using the Antera were shown to depict pore severity similar to raters on photographs, except for Max Depth. Mean pore volume, mean pore area and count were moderately correlated with DermaTOP parameters (up to r = .50). No relationship was seen between the Antera 3D and pore visibility analysis on photographs. The most repeatable parameters were found to be mean pore volume, mean pore area and max depth, especially for the small and medium filters. The benefits of a pore minimizer product were the most striking for mean pore volume and mean pore area when using the small filter for analysis, rather than the medium/large ones. Conclusion: Pore measurements with the Antera 3D represent a reliable tool for efficacy and field studies,Abstract: Background: The cause of enlarged pores remains obscure but still remains of concern for women. To complement subjective methods, bioengineered methods are needed for quantification of pores visibility following treatments. The study objective was to demonstrate the suitability of pore measurements from the Antera 3D. Material and methods: Pore measurements were collected on 22 female volunteers aged 18‐65 years with the Antera 3D, the DermaTOP and image analysis on photographs. Additionally, 4 raters graded pore size on photographs on a scale 0‐5. Repeatability of Antera 3D parameters was ascertained and the benefit of a pore minimizer product on the cheek was assessed on a sub panel of seven female volunteers. Results: Pore parameters using the Antera were shown to depict pore severity similar to raters on photographs, except for Max Depth. Mean pore volume, mean pore area and count were moderately correlated with DermaTOP parameters (up to r = .50). No relationship was seen between the Antera 3D and pore visibility analysis on photographs. The most repeatable parameters were found to be mean pore volume, mean pore area and max depth, especially for the small and medium filters. The benefits of a pore minimizer product were the most striking for mean pore volume and mean pore area when using the small filter for analysis, rather than the medium/large ones. Conclusion: Pore measurements with the Antera 3D represent a reliable tool for efficacy and field studies, with an emphasis of the small filter for analysis for the mean pore volume/mean pore area parameters. … (more)
- Is Part Of:
- Skin research and technology. Volume 24:Issue 4(2018)
- Journal:
- Skin research and technology
- Issue:
- Volume 24:Issue 4(2018)
- Issue Display:
- Volume 24, Issue 4 (2018)
- Year:
- 2018
- Volume:
- 24
- Issue:
- 4
- Issue Sort Value:
- 2018-0024-0004-0000
- Page Start:
- 606
- Page End:
- 613
- Publication Date:
- 2018-04-29
- Subjects:
- Antera -- facial pores -- pore area -- pore volume -- skin imaging
Skin -- Research -- Periodicals
Skin -- Diseases -- Periodicals
Skin -- Physiology -- Periodicals
616.5 - Journal URLs:
- http://www.blackwellpublishing.com/journal.asp?ref=0909-752X&site=1 ↗
http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1600-0846 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/srt.12472 ↗
- Languages:
- English
- ISSNs:
- 0909-752X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 8295.948000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 7936.xml