Application of the 3D digital ostectomy template (DOT) in mandibular angle ostectomy (MAO). Issue 10 (October 2018)
- Record Type:
- Journal Article
- Title:
- Application of the 3D digital ostectomy template (DOT) in mandibular angle ostectomy (MAO). Issue 10 (October 2018)
- Main Title:
- Application of the 3D digital ostectomy template (DOT) in mandibular angle ostectomy (MAO)
- Authors:
- Zhang, Chao
Ma, Merry W.
Xu, Jia-Jie
Lu, Jian-Jian
Xie, Fang
Yang, Li-Ya
Li, Shu-Yuan
Wu, Huan-Huan
Sun, Heng
Yang, Biao
Teng, Li - Abstract:
- Abstract: Background: Mandibular angle ostectomy (MAO) is a standard approach in reconstruction of facial contour that is commonly used in East Asian patients with prominent mandibular angles (PMA). MAO is commonly performed via an intraoral approach to reduce scar visibility and risk of facial nerve injury. Since this intraoral approach for MAO has limited visual guidance during the procedure, plastic surgeons often perform the operation based on personal clinical experience. Therefore, we designed a 3D digital ostectomy template (DOT) for guidance during surgery to improve the accuracy and safety of MAO. Methods: 10 female patients (average age 25.3 years) with PMA were enrolled in this study from August 2014 to October 2015. The DOTs were designed and printed preoperatively and utilized in the operation to guide the osteotomy. The excised mandibular angle bone and the DOTs were measured respective to each other. The data were analyzed to verify the feasibility and safety of the DOT. Results: All of the patients were satisfied with the surgical results, and no complications such as fracture, hemorrhage and infection occurred. The distance from gonion (Go) along inferior margin of mandible forward to the distal end of the excised bone is "a". The distance from Go along posterior margin of ramus upward to the distal end of the excised bone is "b". The widest distance from Go to the ostectomy line is denoted by "c". Similarly, the corresponding distance in the DOT is denotedAbstract: Background: Mandibular angle ostectomy (MAO) is a standard approach in reconstruction of facial contour that is commonly used in East Asian patients with prominent mandibular angles (PMA). MAO is commonly performed via an intraoral approach to reduce scar visibility and risk of facial nerve injury. Since this intraoral approach for MAO has limited visual guidance during the procedure, plastic surgeons often perform the operation based on personal clinical experience. Therefore, we designed a 3D digital ostectomy template (DOT) for guidance during surgery to improve the accuracy and safety of MAO. Methods: 10 female patients (average age 25.3 years) with PMA were enrolled in this study from August 2014 to October 2015. The DOTs were designed and printed preoperatively and utilized in the operation to guide the osteotomy. The excised mandibular angle bone and the DOTs were measured respective to each other. The data were analyzed to verify the feasibility and safety of the DOT. Results: All of the patients were satisfied with the surgical results, and no complications such as fracture, hemorrhage and infection occurred. The distance from gonion (Go) along inferior margin of mandible forward to the distal end of the excised bone is "a". The distance from Go along posterior margin of ramus upward to the distal end of the excised bone is "b". The widest distance from Go to the ostectomy line is denoted by "c". Similarly, the corresponding distance in the DOT is denoted by "a'", "b'", "c'". The statistical results showed that left a vs a', b vs b', c vs c' was 63.27 ± 6.39 mm vs 62.97 ± 6.30 mm (p > 0.05), 23.98 ± 2.25 mm vs 21.83 ± 2.27 mm (p < 0.05), 13.58 ± 2.24 mm vs 13.37 ± 2.14 mm (p > 0.05), respectively. The right a vs a', b vs b', c vs c' was 62.92 ± 5.00 mm vs 62.72 ± 4.99 mm (p > 0.05), 24.03 ± 1.88 mm vs 21.80 ± 1.91 mm (p < 0.05), 13.36 ± 1.70 mm vs 13.22 ± 1.72 mm (p > 0.05), respectively. The results indicate a significant difference between b and b' both on the right and left sides. Conclusion: Through the application of DOT in MAO, the accuracy and safety of the operation were improved significantly. Unfortunately, the osteotomy could not be guided well in the posterior rim of the ramus. Further improvements in the surgical template are needed for application in PMA associated with oversized chin deformity or in PMA associated with large mandibular angle and severe involution. … (more)
- Is Part Of:
- Journal of cranio-maxillofacial surgery. Volume 46:Issue 10(2018)
- Journal:
- Journal of cranio-maxillofacial surgery
- Issue:
- Volume 46:Issue 10(2018)
- Issue Display:
- Volume 46, Issue 10 (2018)
- Year:
- 2018
- Volume:
- 46
- Issue:
- 10
- Issue Sort Value:
- 2018-0046-0010-0000
- Page Start:
- 1821
- Page End:
- 1827
- Publication Date:
- 2018-10
- Subjects:
- Prominent mandibular angle -- Mandibular angle ostectomy -- 3D digital printing technology -- Ostectomy template -- Surgical template
Skull -- Surgery -- Periodicals
Maxilla -- Surgery -- Periodicals
Face -- Surgery -- Periodicals
Surgery, Plastic -- Periodicals
Maxilla -- surgery -- Periodicals
Face -- surgery -- Periodicals
Skull -- surgery -- Periodicals
Oral Surgical Procedures -- Periodicals
Reconstructive Surgical Procedures -- Periodicals
Surgery, Plastic -- Periodicals
Surgery, Oral -- Periodicals
Electronic journals
617.514 - Journal URLs:
- http://www.sciencedirect.com/science/journal/10105182 ↗
http://firstsearch.oclc.org ↗
http://www.clinicalkey.com/dura/browse/journalIssue/10105182 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.jcms.2018.07.026 ↗
- Languages:
- English
- ISSNs:
- 1010-5182
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4965.482000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 7946.xml