Impact of inter-observer variations in target volume delineation on dose volume indices for accelerated partial breast irradiation with multi-catheter interstitial brachytherapy. Issue 1 (October 2018)
- Record Type:
- Journal Article
- Title:
- Impact of inter-observer variations in target volume delineation on dose volume indices for accelerated partial breast irradiation with multi-catheter interstitial brachytherapy. Issue 1 (October 2018)
- Main Title:
- Impact of inter-observer variations in target volume delineation on dose volume indices for accelerated partial breast irradiation with multi-catheter interstitial brachytherapy
- Authors:
- Upreti, Ritu Raj
Budrukkar, Ashwini
Upreti, Udita
Wadasadawala, Tabassum
Misra, Shagun
Gurram, Lavanya
Pathak, Rima
Deshpande, Deepak D. - Abstract:
- Abstract: Purpose: To investigate dosimetric impact of inter-observer variation in clinical target volume(CTV) delineation for patients undergoing interstitial partial breast brachytherapy. Methods: Five radiation oncologists delineated CTV in twenty patients who underwent multi-catheter partial breast brachytherapy. Five treatment plans for each patient were graphically optimized for CTV of all observers and evaluated using coverage index(CI), external volume index(EI), overdose volume index(OI) and conformal index(COIN). In addition, volume enclosed by prescription isodose(V100 ), its spatial concordance(CIcommon ), mean coverage of all CTVs with common volume of prescription dose(V100_common ) and mean CTV coverage for all pairs of observer with common prescription volume of respective pairs(V100_pair ) were also computed. Results: The mean ± standard deviation(SD) of CI and COIN ranged from 0.756 ± 0.076 to 0.840 ± 0.070 and 0.591 ± 0.090 to 0.673 ± 0.06 respectively. When a plan made for CTV of individual observer was evaluated on CTV of all observers, the maximum variations( ρ < 0.05) in the mean CI, COIN, OI and EI were 10.6%, 11.4%, 10.6% and 72.7% respectively. The observed mean ± SD of V100, CIcommon of V100, CTV coverage with V100_common and V100_pair was 160.7 ± 52.1, 0.70 ± 0.09, 73.1 ± 8.1% and 77.9 ± 7.3% respectively. Conclusion: Inter-observer variation in delineation of CTV showed significant dosimetric impact with mean CTV coverage of 73.1% and 77.9% byAbstract: Purpose: To investigate dosimetric impact of inter-observer variation in clinical target volume(CTV) delineation for patients undergoing interstitial partial breast brachytherapy. Methods: Five radiation oncologists delineated CTV in twenty patients who underwent multi-catheter partial breast brachytherapy. Five treatment plans for each patient were graphically optimized for CTV of all observers and evaluated using coverage index(CI), external volume index(EI), overdose volume index(OI) and conformal index(COIN). In addition, volume enclosed by prescription isodose(V100 ), its spatial concordance(CIcommon ), mean coverage of all CTVs with common volume of prescription dose(V100_common ) and mean CTV coverage for all pairs of observer with common prescription volume of respective pairs(V100_pair ) were also computed. Results: The mean ± standard deviation(SD) of CI and COIN ranged from 0.756 ± 0.076 to 0.840 ± 0.070 and 0.591 ± 0.090 to 0.673 ± 0.06 respectively. When a plan made for CTV of individual observer was evaluated on CTV of all observers, the maximum variations( ρ < 0.05) in the mean CI, COIN, OI and EI were 10.6%, 11.4%, 10.6% and 72.7% respectively. The observed mean ± SD of V100, CIcommon of V100, CTV coverage with V100_common and V100_pair was 160.7 ± 52.1, 0.70 ± 0.09, 73.1 ± 8.1% and 77.9 ± 7.3% respectively. Conclusion: Inter-observer variation in delineation of CTV showed significant dosimetric impact with mean CTV coverage of 73.1% and 77.9% by common and paired prescription dose volume respectively among all observers. … (more)
- Is Part Of:
- Radiotherapy and oncology. Volume 129:Issue 1(2018)
- Journal:
- Radiotherapy and oncology
- Issue:
- Volume 129:Issue 1(2018)
- Issue Display:
- Volume 129, Issue 1 (2018)
- Year:
- 2018
- Volume:
- 129
- Issue:
- 1
- Issue Sort Value:
- 2018-0129-0001-0000
- Page Start:
- 173
- Page End:
- 179
- Publication Date:
- 2018-10
- Subjects:
- Interobserver variation -- Multicatheter interstitial brachytherapy -- Dose volume indices -- Accelerated partial breast irradiation
Oncology -- Periodicals
Radiotherapy -- Periodicals
Tumors -- Periodicals
Medical Oncology -- Periodicals
Neoplasms -- radiotherapy -- Periodicals
Radiotherapy -- Periodicals
Radiothérapie -- Périodiques
Cancérologie -- Périodiques
Tumeurs -- Périodiques
Electronic journals
616.9940642 - Journal URLs:
- http://www.sciencedirect.com/science/journal/01678140 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/01678140 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/01678140 ↗
http://www.estro.org/ ↗
http://www.elsevier.com/journals ↗
http://www.journals.elsevier.com/radiotherapy-and-oncology/ ↗ - DOI:
- 10.1016/j.radonc.2018.06.029 ↗
- Languages:
- English
- ISSNs:
- 0167-8140
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 7240.790000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 7965.xml