Original intensity preserved inhomogeneity correction and segmentation for liver magnetic resonance imaging. (January 2019)
- Record Type:
- Journal Article
- Title:
- Original intensity preserved inhomogeneity correction and segmentation for liver magnetic resonance imaging. (January 2019)
- Main Title:
- Original intensity preserved inhomogeneity correction and segmentation for liver magnetic resonance imaging
- Authors:
- Liu, Hui
Liu, Shanshan
Guo, Dongmei
Zheng, Yuanjie
Tang, Pinpin
Dan, Guo - Abstract:
- Highlights: The MRI with bias field is corrected with the proposed method. The fuzzy membership mask is used to remove the background noise. Bias field correction can increase the accuracy of segmentation. The proposed method has been successfully applied to the clinical liver MRI. Abstract: Intensity inhomogeneity (IIH), also named as bias field, is an undesired phenomenon of liver magnetic resonance imaging (MRI) which severely affects the quantitative analysis of medical image and decreases the performance of subsequent computer aided diagnosis (CAD) of liver cirrhosis. Many algorithms have been proposed to reduce or eliminate IIH of MRI, and some notable achievements for brain MRI have been obtained. However, IIH correction of abdominal MRI receives less attention and is challenging because of the irregular structure and the wide intensity range of different tissues. In this paper, an automatic method based on the global intensity, the local intensity and the spatial continuity information is presented for reducing IIH of liver MRI. What should be noted is that the gray level should be preserved after correction since it is important for subsequent quantitative image analysis. Therefore, a constraint term is introduced based on the information of bias field intensity for appropriate IIH correction. In addition, the objective function introduces a fuzzy membership mask to remove the background noise and avoid misclassification. Our method is successfully applied to theHighlights: The MRI with bias field is corrected with the proposed method. The fuzzy membership mask is used to remove the background noise. Bias field correction can increase the accuracy of segmentation. The proposed method has been successfully applied to the clinical liver MRI. Abstract: Intensity inhomogeneity (IIH), also named as bias field, is an undesired phenomenon of liver magnetic resonance imaging (MRI) which severely affects the quantitative analysis of medical image and decreases the performance of subsequent computer aided diagnosis (CAD) of liver cirrhosis. Many algorithms have been proposed to reduce or eliminate IIH of MRI, and some notable achievements for brain MRI have been obtained. However, IIH correction of abdominal MRI receives less attention and is challenging because of the irregular structure and the wide intensity range of different tissues. In this paper, an automatic method based on the global intensity, the local intensity and the spatial continuity information is presented for reducing IIH of liver MRI. What should be noted is that the gray level should be preserved after correction since it is important for subsequent quantitative image analysis. Therefore, a constraint term is introduced based on the information of bias field intensity for appropriate IIH correction. In addition, the objective function introduces a fuzzy membership mask to remove the background noise and avoid misclassification. Our method is successfully applied to the clinical liver MRI and acquires desirable results. Compared with other approaches, our method obtains the best segmentation with Jaccard similarity (JS) = 0.88 ± 0.06, Dice index (DI) = 0.94 ± 0.03, and accuracy (ACC) = 0.99 ± 0.01. … (more)
- Is Part Of:
- Biomedical signal processing and control. Volume 47(2019)
- Journal:
- Biomedical signal processing and control
- Issue:
- Volume 47(2019)
- Issue Display:
- Volume 47, Issue 2019 (2019)
- Year:
- 2019
- Volume:
- 47
- Issue:
- 2019
- Issue Sort Value:
- 2019-0047-2019-0000
- Page Start:
- 231
- Page End:
- 239
- Publication Date:
- 2019-01
- Subjects:
- Bias field -- Intensity inhomogeneity -- Fuzzy membership mask -- Spatial continuity information
Signal processing -- Periodicals
Biomedical engineering -- Periodicals
Signal Processing, Computer-Assisted -- Periodicals
Image Processing, Computer-Assisted -- Periodicals
Biomedical Engineering -- Periodicals
610.28 - Journal URLs:
- http://www.sciencedirect.com/science/journal/17468094 ↗
http://www.elsevier.com/journals ↗
http://www.sciencedirect.com/science?_ob=PublicationURL&_tockey=%23TOC%2329675%232006%23999989998%23626449%23FLA%23&_cdi=29675&_pubType=J&_auth=y&_acct=C000045259&_version=1&_urlVersion=0&_userid=836873&md5=664b5cf9a57fc91971a17faf20c32ec1 ↗ - DOI:
- 10.1016/j.bspc.2018.08.005 ↗
- Languages:
- English
- ISSNs:
- 1746-8094
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 2087.880400
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 7951.xml