- Breast cancer staging: Combined digital breast tomosynthesis and automated breast ultrasound versus magnetic resonance imaging
- Authors:
- Girometti, Rossano
Tomkova, Ludmila
Cereser, Lorenzo
Zuiani, Chiara - Abstract:
- Abstract: Purpose: To investigate whether combined Digital breast tomosynthesis and Automated breast volume scanner (DBT-ABVS) are comparable to Magnetic resonance imaging (MRI) in staging breast cancer. Methods: We retrospectively included seventy-three patients with histologically proven breast cancer who underwent preoperative DBT, ABVS and 1.5 T MRI in the period July 2015–July 2016. Two radiologists in consensus recorded the number, site and Breast imaging-reporting and data system (BI-RADS) category of breast findings during two independent reading strategies, i.e. DBT-ABVS vs. MRI. Using histology or 1-year follow up as the standard of reference, we calculated the accuracy for cancer of both imaging strategies. Bland-Altman analysis was used to evaluate the agreement between MRI vs. DBT or ABVS in cancer size assessment. Results: Patients showed a total of 160 lesions (108 malignant and 52 benign). Malignant lesions were unifocal, multifocal, multicentric and biltateral in 53, 15, 4 and 1 cases, respectively. Diagnostic accuracy of DBT-ABVS vs. MRI was comparable for all cancers (90.0% [95%C.I. 84.3–94.2] vs. 93.8% [95%C.I. 88.8–97.0], respectively). DBT-ABVS showed lower sensitivity and positive predictive values for additional disease (76.5% [95%C.I. 58.8–89.3] vs. 91.7% [95%C.I. 84.6–96.1], and 78.8% [95%C.I. 61.0–91.0] vs 93.4% [95%C.I. 86.9–97.3], respectively). Compared to MRI, ABVS + DBT missed 6 lesions, including two invasive cancers and one extensiveAbstract: Purpose: To investigate whether combined Digital breast tomosynthesis and Automated breast volume scanner (DBT-ABVS) are comparable to Magnetic resonance imaging (MRI) in staging breast cancer. Methods: We retrospectively included seventy-three patients with histologically proven breast cancer who underwent preoperative DBT, ABVS and 1.5 T MRI in the period July 2015–July 2016. Two radiologists in consensus recorded the number, site and Breast imaging-reporting and data system (BI-RADS) category of breast findings during two independent reading strategies, i.e. DBT-ABVS vs. MRI. Using histology or 1-year follow up as the standard of reference, we calculated the accuracy for cancer of both imaging strategies. Bland-Altman analysis was used to evaluate the agreement between MRI vs. DBT or ABVS in cancer size assessment. Results: Patients showed a total of 160 lesions (108 malignant and 52 benign). Malignant lesions were unifocal, multifocal, multicentric and biltateral in 53, 15, 4 and 1 cases, respectively. Diagnostic accuracy of DBT-ABVS vs. MRI was comparable for all cancers (90.0% [95%C.I. 84.3–94.2] vs. 93.8% [95%C.I. 88.8–97.0], respectively). DBT-ABVS showed lower sensitivity and positive predictive values for additional disease (76.5% [95%C.I. 58.8–89.3] vs. 91.7% [95%C.I. 84.6–96.1], and 78.8% [95%C.I. 61.0–91.0] vs 93.4% [95%C.I. 86.9–97.3], respectively). Compared to MRI, ABVS + DBT missed 6 lesions, including two invasive cancers and one extensive intravascular invasion associated to ductal carcinoma in situ. Bland-Altman analysis showed ABVS to agree with MRI at a higher extent than DBT in assessing cancer size. Conclusions: Though less performing than MRI, DBT-ABVS showed acceptable diagnostic accuracy in staging breast cancer. This strategy might be used if MRI is unavailable or unfeasible. … (more)
- Is Part Of:
- European journal of radiology. Issue 107(2018)
- Journal:
- European journal of radiology
- Issue:
- Issue 107(2018)
- Issue Display:
- Volume 107, Issue 107 (2018)
- Year:
- 2018
- Volume:
- 107
- Issue:
- 107
- Issue Sort Value:
- 2018-0107-0107-0000
- Page Start:
- 188
- Page End:
- 195
- Publication Date:
- 2018-10
- Subjects:
- Breast cancer -- Digital breast -- Tomosynthesis -- Automated breast volume scanner -- Magnetic resonance imaging
Medical radiology -- Periodicals
Radiology -- Periodicals
Radiologie médicale -- Périodiques
Medical radiology
Periodicals
616.075705 - Journal URLs:
- http://www.sciencedirect.com/science/journal/0720048X ↗
http://www.elsevier.com/homepage/elecserv.htt ↗
http://www.clinicalkey.com/dura/browse/journalIssue/0720048X ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/0720048X ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.ejrad.2018.09.002 ↗
- Languages:
- English
- ISSNs:
- 0720-048X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.738050
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 7948.xml