Native cardiac T1 Mapping: Standardized inline analysis of long and short axis at three identical 1.5 Tesla MRI scanners. Issue 107 (October 2018)
- Record Type:
- Journal Article
- Title:
- Native cardiac T1 Mapping: Standardized inline analysis of long and short axis at three identical 1.5 Tesla MRI scanners. Issue 107 (October 2018)
- Main Title:
- Native cardiac T1 Mapping: Standardized inline analysis of long and short axis at three identical 1.5 Tesla MRI scanners
- Authors:
- Heiss, Rafael
Wiesmueller, Marco
Uder, Michael
May, Matthias S.
Wuest, Wolfgang - Abstract:
- Highlights: High reproducibility of native cardiac T1 mapping independently of the heart segment. Limited comparability between corresponding short and long axis segments. To get reliable results multiple planes and axis should be acquired. Follow-up examinations should be measured in identical segments. Abstract: Background: Interpretation of native T1 time values remains difficult due to limited hard- and software comparability and the lack of measurement recommendations for the number of slices and their orientation. To provide a standardized comparison of native T1 time values in short and long axis and to investigate the interscanner reproducibility. Methods: 78 cardiac MRIs in 26 healthy volunteers were performed with three structurally identical 1.5 T MRI scanners. A commercially available software package for T1 mapping with automatic in-line motion correction was used for analysis. On T1 mapping images regions of interest were manually placed in each of the 16 myocardial segments according to the AHA model in three short and three long axis. Results: A total of 2652 ROIs were drawn and 102 segments per volunteer were analysed. Interscanner reproducibility was high and the mean myocardial T1 time value for all evaluated segments was 996 ± 34 ms. Significant variations of T1 time values were found between heart segments in the same axis. Mean T1 time values were comparable between long and short axis but differed in 33% of corresponding short and long axis segments.Highlights: High reproducibility of native cardiac T1 mapping independently of the heart segment. Limited comparability between corresponding short and long axis segments. To get reliable results multiple planes and axis should be acquired. Follow-up examinations should be measured in identical segments. Abstract: Background: Interpretation of native T1 time values remains difficult due to limited hard- and software comparability and the lack of measurement recommendations for the number of slices and their orientation. To provide a standardized comparison of native T1 time values in short and long axis and to investigate the interscanner reproducibility. Methods: 78 cardiac MRIs in 26 healthy volunteers were performed with three structurally identical 1.5 T MRI scanners. A commercially available software package for T1 mapping with automatic in-line motion correction was used for analysis. On T1 mapping images regions of interest were manually placed in each of the 16 myocardial segments according to the AHA model in three short and three long axis. Results: A total of 2652 ROIs were drawn and 102 segments per volunteer were analysed. Interscanner reproducibility was high and the mean myocardial T1 time value for all evaluated segments was 996 ± 34 ms. Significant variations of T1 time values were found between heart segments in the same axis. Mean T1 time values were comparable between long and short axis but differed in 33% of corresponding short and long axis segments. Conclusions: Native T1 time values in short and long axis are highly reproducible but can vary significantly between heart segments in the same axis. Comparability between corresponding short and long axis segments is limited. To get representative results native T1 time values should be obtained in more than one heart segment and for follow-up studies identical segments should be used to avoid a systematic bias. … (more)
- Is Part Of:
- European journal of radiology. Issue 107(2018)
- Journal:
- European journal of radiology
- Issue:
- Issue 107(2018)
- Issue Display:
- Volume 107, Issue 107 (2018)
- Year:
- 2018
- Volume:
- 107
- Issue:
- 107
- Issue Sort Value:
- 2018-0107-0107-0000
- Page Start:
- 203
- Page End:
- 208
- Publication Date:
- 2018-10
- Subjects:
- Magnetic resonance imaging -- Heart -- Reproducibility of results -- Cross-Sectional study
Medical radiology -- Periodicals
Radiology -- Periodicals
Radiologie médicale -- Périodiques
Medical radiology
Periodicals
616.075705 - Journal URLs:
- http://www.sciencedirect.com/science/journal/0720048X ↗
http://www.elsevier.com/homepage/elecserv.htt ↗
http://www.clinicalkey.com/dura/browse/journalIssue/0720048X ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/0720048X ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.ejrad.2018.09.009 ↗
- Languages:
- English
- ISSNs:
- 0720-048X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.738050
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 7948.xml