A wavelet gradient sparsity based algorithm for reconstruction of reduced-view tomography datasets obtained with a monochromatic synchrotron-based X-ray source. (November 2018)
- Record Type:
- Journal Article
- Title:
- A wavelet gradient sparsity based algorithm for reconstruction of reduced-view tomography datasets obtained with a monochromatic synchrotron-based X-ray source. (November 2018)
- Main Title:
- A wavelet gradient sparsity based algorithm for reconstruction of reduced-view tomography datasets obtained with a monochromatic synchrotron-based X-ray source
- Authors:
- Melli, S. Ali
Wahid, Khan A.
Babyn, Paul
Cooper, David M.L.
Hasan, Ahmed M. - Abstract:
- Highlights: Proposing a tomographic image reconstruction algorithm to reduce the overall radiation dose and scan time which improves in-vivo imaging protocols. Reconstruction of a high resolution tomographic image with acceptable quality from a synchrotron dataset with a significantly reduced number of projections. Abstract: High-resolution synchrotron computed tomography (CT) is very helpful in the diagnosis and monitor of chronic diseases including osteoporosis. Osteoporosis is characterized by low bone mass and cortical bone porosity best imaged with CT. Synchrotron CT requires a large number of angular projections to reconstruct images with high resolution for detailed and accurate diagnosis. However, this poses great risks and challenges for serial in-vivo human and animal imaging due to a large amount of X-ray radiation dose required that can damage living specimens. Also, longer scan times are associated with increased risk of specimen movement and motion artifact in the reconstructed images. We developed a wavelet-gradient sparsity based algorithm to be utilized as a synchrotron tomography reconstruction technique allowing accurate reconstruction of cortical bone porosity assessed for in-vivo preclinical study which significantly reduces the radiation dose and scan time required while maintaining satisfactory image resolution for diagnosis. The results of our study on a rat forelimb sample imaged in the Biomedical Imaging and Therapy Bending Magnet (BMIT-BM) beamlineHighlights: Proposing a tomographic image reconstruction algorithm to reduce the overall radiation dose and scan time which improves in-vivo imaging protocols. Reconstruction of a high resolution tomographic image with acceptable quality from a synchrotron dataset with a significantly reduced number of projections. Abstract: High-resolution synchrotron computed tomography (CT) is very helpful in the diagnosis and monitor of chronic diseases including osteoporosis. Osteoporosis is characterized by low bone mass and cortical bone porosity best imaged with CT. Synchrotron CT requires a large number of angular projections to reconstruct images with high resolution for detailed and accurate diagnosis. However, this poses great risks and challenges for serial in-vivo human and animal imaging due to a large amount of X-ray radiation dose required that can damage living specimens. Also, longer scan times are associated with increased risk of specimen movement and motion artifact in the reconstructed images. We developed a wavelet-gradient sparsity based algorithm to be utilized as a synchrotron tomography reconstruction technique allowing accurate reconstruction of cortical bone porosity assessed for in-vivo preclinical study which significantly reduces the radiation dose and scan time required while maintaining satisfactory image resolution for diagnosis. The results of our study on a rat forelimb sample imaged in the Biomedical Imaging and Therapy Bending Magnet (BMIT-BM) beamline at the Canadian Light Source show that the proposed algorithm can produce satisfactory image quality with more than 50 percent X-ray dose reduction as indicated by both visual and quantitative-based performance. … (more)
- Is Part Of:
- Computerized medical imaging and graphics. Volume 69(2018)
- Journal:
- Computerized medical imaging and graphics
- Issue:
- Volume 69(2018)
- Issue Display:
- Volume 69, Issue 2018 (2018)
- Year:
- 2018
- Volume:
- 69
- Issue:
- 2018
- Issue Sort Value:
- 2018-0069-2018-0000
- Page Start:
- 69
- Page End:
- 81
- Publication Date:
- 2018-11
- Subjects:
- Reduced-view computed tomography reconstruction -- X-ray dose reduction in high-resolution imaging of bone microstructure -- Reduction of in vivo synchrotron-based X-ray source computed tomography scan time
Diagnostic imaging -- Periodicals
Imaging systems in medicine -- Periodicals
Diagnosis, Radioscopic -- Data processing -- Periodicals
Diagnostic Imaging -- Periodicals
Imagerie pour le diagnostic -- Périodiques
Diagnostic imaging
Periodicals
Electronic journals
Electronic journals
616.0754 - Journal URLs:
- http://www.journals.elsevier.com/computerized-medical-imaging-and-graphics/ ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.compmedimag.2018.08.005 ↗
- Languages:
- English
- ISSNs:
- 0895-6111
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3394.586000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 7950.xml