Optimizing the deformation behavior of stent with nonuniform Poisson's ratio distribution for curved artery. (December 2018)
- Record Type:
- Journal Article
- Title:
- Optimizing the deformation behavior of stent with nonuniform Poisson's ratio distribution for curved artery. (December 2018)
- Main Title:
- Optimizing the deformation behavior of stent with nonuniform Poisson's ratio distribution for curved artery
- Authors:
- Han, Yafeng
Lu, Wenfeng - Abstract:
- Abstract: Stent implantation at a highly curved artery has always been a challenge, considering the relatively high chance of in-stent restenosis (ISR) caused by severe straightening effect and high strain energy over the vessel wall. In this paper, a novel optimization based design method was proposed to manipulate the deformation behavior of the common ring-and-link stent. By changing the location of the connection point between rings and links, traditional ring-and-link structure was modified to achiever tunable Poisson's ratio (PR). With the nonuniform cellular structure design method proposed in a previous study, PR distribution of the stent structure was optimized to achieve the desired curvature. As a result, the obtained stent structure with nonuniform PR could perfectly fit into the curved artery after expansion, without causing any obvious vessel straightening. To validate the proposed method, two different vessel models were introduced. Firstly, a short vessel with a constant curvature was set as the design objective, and both numerical and experimental tests were conducted. Further, a patient-specific vessel was applied. Both test results showed that optimized stents would cause much smaller vessel straightening. Moreover, vessels stented by the optimized structures had much lower stress concentration and strain energy. All those properties will decrease the possibility of ISR significantly. Graphic abstract: Highlights: The newly designed stent structure canAbstract: Stent implantation at a highly curved artery has always been a challenge, considering the relatively high chance of in-stent restenosis (ISR) caused by severe straightening effect and high strain energy over the vessel wall. In this paper, a novel optimization based design method was proposed to manipulate the deformation behavior of the common ring-and-link stent. By changing the location of the connection point between rings and links, traditional ring-and-link structure was modified to achiever tunable Poisson's ratio (PR). With the nonuniform cellular structure design method proposed in a previous study, PR distribution of the stent structure was optimized to achieve the desired curvature. As a result, the obtained stent structure with nonuniform PR could perfectly fit into the curved artery after expansion, without causing any obvious vessel straightening. To validate the proposed method, two different vessel models were introduced. Firstly, a short vessel with a constant curvature was set as the design objective, and both numerical and experimental tests were conducted. Further, a patient-specific vessel was applied. Both test results showed that optimized stents would cause much smaller vessel straightening. Moreover, vessels stented by the optimized structures had much lower stress concentration and strain energy. All those properties will decrease the possibility of ISR significantly. Graphic abstract: Highlights: The newly designed stent structure can perfectly fit into the outline of the curved artery. Nonuniform Poisson's ratio distribution was easily achieved by modifying the traditional ring-and-link structure. Smooth transition between unit cells with different Poisson's ratio was maintained for a better deformation curvature. Much lower strain energy and stress concentration was applied on the vessel wall. … (more)
- Is Part Of:
- Journal of the mechanical behavior of biomedical materials. Volume 88(2018)
- Journal:
- Journal of the mechanical behavior of biomedical materials
- Issue:
- Volume 88(2018)
- Issue Display:
- Volume 88, Issue 2018 (2018)
- Year:
- 2018
- Volume:
- 88
- Issue:
- 2018
- Issue Sort Value:
- 2018-0088-2018-0000
- Page Start:
- 442
- Page End:
- 452
- Publication Date:
- 2018-12
- Subjects:
- Ring-and-link stent structure -- Deformation behavior -- Negative Poisson's ratio -- Nonuniform structure -- Curved arteries -- In-stent restenosis
Biomedical materials -- Periodicals
Biomedical materials -- Mechanical properties -- Periodicals
Biomedical materials
Biomedical materials -- Mechanical properties
Periodicals
Electronic journals
610.28 - Journal URLs:
- http://www.sciencedirect.com/science/journal/17516161 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.jmbbm.2018.09.005 ↗
- Languages:
- English
- ISSNs:
- 1751-6161
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5015.809000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 7965.xml