Cardiac Output Assessment in Patients Supported with Left Ventricular Assist Device: Discordance Between Thermodilution and Indirect Fick Cardiac Output Measurements. Issue 4 (July 2017)
- Record Type:
- Journal Article
- Title:
- Cardiac Output Assessment in Patients Supported with Left Ventricular Assist Device: Discordance Between Thermodilution and Indirect Fick Cardiac Output Measurements. Issue 4 (July 2017)
- Main Title:
- Cardiac Output Assessment in Patients Supported with Left Ventricular Assist Device
- Authors:
- Tehrani, David M.
Grinstein, Jonathan
Kalantari, Sara
Kim, Gene
Sarswat, Nitasha
Adatya, Sirtaz
Sayer, Gabriel
Uriel, Nir - Abstract:
- Abstract : Cardiac output (CO) assessed by thermodilution (TD) and indirect Fick (iFK) methods is commonly employed in left ventricular assist device (LVAD) patients; however, no study has assessed agreement. This study assesses correlation between these methods and association with hemodynamic/echocardiographic data in LVAD patients. Discordance was defined as a 20% difference between TD and iFK CO measurements. Bias and agreement were determined via the Bland–Altman technique in both the overall sample and iFK-stratified tertiles. Correlation with each assessment of CO and right heart catheterization (RHC) hemodynamics was performed. Among 111 RHCs, the mean CO for TD and iFK were 4.65 ± 1.33 (range: 1.44–9.30) and 5.37 ± 1.51 (range: 3.07–11.80) L/min ( p < 0.001), respectively, with a calculated discordance of 45.9%. A correlation coefficient of 0.66 with a bias of −0.72 L/min was found. The lower and upper limit of precision were −3.12 and 1.68 L/min, respectively. By tertile analysis, bias (lower and upper limit of precision) for the low, middle, and high tertile groups were −0.24 (−1.88 and 1.40), −0.48 (−2.50 and 1.53), and −1.39 (−4.18 and 1.39) L/min, respectively. No significant correlation was found between either method with right atrial pressure or pulmonary capillary wedge pressure or any valvular condition. Substantial discrepancies exist between TD and iFK CO in LVAD patients. Although fixed bias was small, the limits of agreement extend into the clinicallyAbstract : Cardiac output (CO) assessed by thermodilution (TD) and indirect Fick (iFK) methods is commonly employed in left ventricular assist device (LVAD) patients; however, no study has assessed agreement. This study assesses correlation between these methods and association with hemodynamic/echocardiographic data in LVAD patients. Discordance was defined as a 20% difference between TD and iFK CO measurements. Bias and agreement were determined via the Bland–Altman technique in both the overall sample and iFK-stratified tertiles. Correlation with each assessment of CO and right heart catheterization (RHC) hemodynamics was performed. Among 111 RHCs, the mean CO for TD and iFK were 4.65 ± 1.33 (range: 1.44–9.30) and 5.37 ± 1.51 (range: 3.07–11.80) L/min ( p < 0.001), respectively, with a calculated discordance of 45.9%. A correlation coefficient of 0.66 with a bias of −0.72 L/min was found. The lower and upper limit of precision were −3.12 and 1.68 L/min, respectively. By tertile analysis, bias (lower and upper limit of precision) for the low, middle, and high tertile groups were −0.24 (−1.88 and 1.40), −0.48 (−2.50 and 1.53), and −1.39 (−4.18 and 1.39) L/min, respectively. No significant correlation was found between either method with right atrial pressure or pulmonary capillary wedge pressure or any valvular condition. Substantial discrepancies exist between TD and iFK CO in LVAD patients. Although fixed bias was small, the limits of agreement extend into the clinically relevant area, with larger bias being present at higher CO. Studies with flow probes are needed to define which method better represents CO in LVAD patients. … (more)
- Is Part Of:
- ASAIO journal. Volume 63:Issue 4(2017)
- Journal:
- ASAIO journal
- Issue:
- Volume 63:Issue 4(2017)
- Issue Display:
- Volume 63, Issue 4 (2017)
- Year:
- 2017
- Volume:
- 63
- Issue:
- 4
- Issue Sort Value:
- 2017-0063-0004-0000
- Page Start:
- Page End:
- Publication Date:
- 2017-07
- Subjects:
- LVAD -- cardiac output -- indirect Fick -- thermodilution
Artificial organs -- Periodicals
617 - Journal URLs:
- http://journals.lww.com/asaiojournal/pages/default.aspx ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/MAT.0000000000000528 ↗
- Languages:
- English
- ISSNs:
- 1058-2916
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 1738.840500
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 7928.xml