Impact of a new sampling buffer on faecal haemoglobin stability in a colorectal cancer screening programme by the faecal immunochemical test. Issue 4 (July 2017)
- Record Type:
- Journal Article
- Title:
- Impact of a new sampling buffer on faecal haemoglobin stability in a colorectal cancer screening programme by the faecal immunochemical test. Issue 4 (July 2017)
- Main Title:
- Impact of a new sampling buffer on faecal haemoglobin stability in a colorectal cancer screening programme by the faecal immunochemical test
- Authors:
- Grazzini, Grazia
Ventura, Leonardo
Rubeca, Tiziana
Rapi, Stefano
Cellai, Filippo
Di Dia, Pietro P.
Mallardi, Beatrice
Mantellini, Paola
Zappa, Marco
Castiglione, Guido - Abstract:
- Abstract : Haemoglobin (Hb) stability in faecal samples is an important issue in colorectal cancer screening by the faecal immunochemical test (FIT) for Hb. This study evaluated the performance of the FIT-Hb (OC-Sensor Eiken) used in the Florence screening programme by comparing two different formulations of the buffer, both in an analytical and in a clinical setting. In the laboratory simulation, six faecal pools (three in each buffer type) were stored at different temperatures and analysed eight times in 10 replicates over 21 days. In the clinical setting, 7695 screenees returned two samples, using both the old and the new specimen collection device (SCD). In the laboratory simulation, 5 days from sample preparation with the buffer of the old SCD, the Hb concentration decreased by 40% at room temperature (25°C, range 22–28°C) and up to 60% at outside temperature (29°C, range 16–39°C), whereas with the new one, Hb concentration decreased by 10%. In the clinical setting, a higher mean Hb concentration with the new SCD compared with the old one was found (6.3 vs. 5.0 µg Hb/g faeces, respectively, P <0.001); no statistically significant difference was found in the probability of having a positive result in the two SCDs. Better Hb stability was observed with the new buffer under laboratory conditions, but no difference was found in the clinical performance. In our study, only marginal advantages arise from the new buffer. Improvements in sample stability represent a significantAbstract : Haemoglobin (Hb) stability in faecal samples is an important issue in colorectal cancer screening by the faecal immunochemical test (FIT) for Hb. This study evaluated the performance of the FIT-Hb (OC-Sensor Eiken) used in the Florence screening programme by comparing two different formulations of the buffer, both in an analytical and in a clinical setting. In the laboratory simulation, six faecal pools (three in each buffer type) were stored at different temperatures and analysed eight times in 10 replicates over 21 days. In the clinical setting, 7695 screenees returned two samples, using both the old and the new specimen collection device (SCD). In the laboratory simulation, 5 days from sample preparation with the buffer of the old SCD, the Hb concentration decreased by 40% at room temperature (25°C, range 22–28°C) and up to 60% at outside temperature (29°C, range 16–39°C), whereas with the new one, Hb concentration decreased by 10%. In the clinical setting, a higher mean Hb concentration with the new SCD compared with the old one was found (6.3 vs. 5.0 µg Hb/g faeces, respectively, P <0.001); no statistically significant difference was found in the probability of having a positive result in the two SCDs. Better Hb stability was observed with the new buffer under laboratory conditions, but no difference was found in the clinical performance. In our study, only marginal advantages arise from the new buffer. Improvements in sample stability represent a significant target in the screening setting. … (more)
- Is Part Of:
- European journal of cancer prevention. Volume 26:Issue 4(2017)
- Journal:
- European journal of cancer prevention
- Issue:
- Volume 26:Issue 4(2017)
- Issue Display:
- Volume 26, Issue 4 (2017)
- Year:
- 2017
- Volume:
- 26
- Issue:
- 4
- Issue Sort Value:
- 2017-0026-0004-0000
- Page Start:
- Page End:
- Publication Date:
- 2017-07
- Subjects:
- cancer prevention -- colorectal cancer screening -- faecal immunochemical test -- sample stability
Cancer -- Prevention -- Periodicals
Neoplasms -- etiology -- Periodicals
Neoplasms -- prevention & control -- Periodicals
Cancer -- Prevention
Periodicals
616.994052 - Journal URLs:
- http://journals.lww.com/eurjcancerprev/pages/default.aspx ↗
http://mclink.library.mcgill.ca/sfx?url_ver=Z39.88-2004&ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&rfr_id=info:sid/sfxit.com:opac_856&url_ctx_fmt=info:ofi/fmt:kev:mtx:ctx&sfx.ignore_date_threshold=1&rft.object_id=954925578081 ↗
http://ovidsp.ovid.com/ovidweb.cgi?T=JS&NEWS=n&CSC=Y&PAGE=toc&D=yrovft&AN=00008469-000000000-00000 ↗
http://www.eurjcancerprev.com/ ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/CEJ.0000000000000257 ↗
- Languages:
- English
- ISSNs:
- 0959-8278
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.725400
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 7917.xml