Radiation dose for normal organs by helical tomotherapy for lung cancer. (August 2015)
- Record Type:
- Journal Article
- Title:
- Radiation dose for normal organs by helical tomotherapy for lung cancer. (August 2015)
- Main Title:
- Radiation dose for normal organs by helical tomotherapy for lung cancer
- Authors:
- Tseng, Hsien-Chun
Liu, Wen-Shan
Tsai, Hsiao-Han
Chu, Hsin-Yi
Lin, Jye-Bin
Chen, Chien-Yi - Abstract:
- Abstract: This study derived a simple equation of effective dose ( E ) versus normal organ of patients with varying body weights undergoing lung cancer treatment of helical tomotherapy (TOMO). Five tissue-equivalent and Rando phantoms were used to simulate lung cancer patients. This study then measured E and equivalent dose of organ or tissues ( D T ) using thermoluminescent dosimetry (TLD-100H). The TLD-100H was calibrated using TOMO 6 MV photons, then inserted into phantom positions that closely corresponded with the position of the represented organs and tissues. Both E and D T were evaluated by ICRP 103. Peripheral doses varied markedly at positions close to the tumor center. The maximum statistical and total errors were 16.7–22.3%. This analytical result indicates that E of Rando and tissue-equivalent phantoms was in the ranged of 9.44±1.70 (10 kg) to 4.58±0.83 (90 kg) mSv/Gy. Notably, E decreased exponentially as phantom weight increased. Peripheral doses were also evaluated by TLD as a function of distance from the tumor center. Finally, experimental results are compared with those in literature. These findings will prove useful to patients, physicians, radiologists, and the public. Highlights: Phantoms were used to measure effective dose of helical tomotherapy. TLDs inserted into five varying body weights phantoms. Both effective dose and equivalent dose of organ were evaluated by ICRP 103. Effective dose decreased exponentially as phantom weight increased.Abstract: This study derived a simple equation of effective dose ( E ) versus normal organ of patients with varying body weights undergoing lung cancer treatment of helical tomotherapy (TOMO). Five tissue-equivalent and Rando phantoms were used to simulate lung cancer patients. This study then measured E and equivalent dose of organ or tissues ( D T ) using thermoluminescent dosimetry (TLD-100H). The TLD-100H was calibrated using TOMO 6 MV photons, then inserted into phantom positions that closely corresponded with the position of the represented organs and tissues. Both E and D T were evaluated by ICRP 103. Peripheral doses varied markedly at positions close to the tumor center. The maximum statistical and total errors were 16.7–22.3%. This analytical result indicates that E of Rando and tissue-equivalent phantoms was in the ranged of 9.44±1.70 (10 kg) to 4.58±0.83 (90 kg) mSv/Gy. Notably, E decreased exponentially as phantom weight increased. Peripheral doses were also evaluated by TLD as a function of distance from the tumor center. Finally, experimental results are compared with those in literature. These findings will prove useful to patients, physicians, radiologists, and the public. Highlights: Phantoms were used to measure effective dose of helical tomotherapy. TLDs inserted into five varying body weights phantoms. Both effective dose and equivalent dose of organ were evaluated by ICRP 103. Effective dose decreased exponentially as phantom weight increased. Peripheral doses varied markedly close to the tumor center. … (more)
- Is Part Of:
- Applied radiation and isotopes. Volume 102(2015:Aug.)
- Journal:
- Applied radiation and isotopes
- Issue:
- Volume 102(2015:Aug.)
- Issue Display:
- Volume 102 (2015)
- Year:
- 2015
- Volume:
- 102
- Issue Sort Value:
- 2015-0102-0000-0000
- Page Start:
- 35
- Page End:
- 41
- Publication Date:
- 2015-08
- Subjects:
- Helical tomotherapy (TOMO) -- Effective dose (E) -- Equivalent dose of organ or tissues (DT) -- Peripheral dose -- Lung cancer -- TLD -- Tissue-equivalent phantom -- ICRP 103
Radiology -- Periodicals
Radiation -- Industrial applications -- Periodicals
Nuclear chemistry -- Periodicals
Internet resource
Periodical
660.298 - Journal URLs:
- http://www.sciencedirect.com/science/journal/09698043 ↗
http://catalog.hathitrust.org/api/volumes/oclc/27456684.html ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.apradiso.2015.04.007 ↗
- Languages:
- English
- ISSNs:
- 0969-8043
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 1576.565000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 7888.xml