Ionization density dependence of the curve shape and ratio of blue to UV emissions of Al2O3:C optically stimulated luminescence detectors exposed to 6-MV photon and therapeutic proton beams. (June 2016)
- Record Type:
- Journal Article
- Title:
- Ionization density dependence of the curve shape and ratio of blue to UV emissions of Al2O3:C optically stimulated luminescence detectors exposed to 6-MV photon and therapeutic proton beams. (June 2016)
- Main Title:
- Ionization density dependence of the curve shape and ratio of blue to UV emissions of Al2O3:C optically stimulated luminescence detectors exposed to 6-MV photon and therapeutic proton beams
- Authors:
- Flint, David B.
Granville, Dal A.
Sahoo, Narayan
McEwen, Malcolm
Sawakuchi, Gabriel O. - Abstract:
- Abstract: In this work we characterized the dose and linear energy transfer (LET) (ionization density) dependence of commercial Al2 O3 :C optically stimulated luminescence (OSL) detectors (OSLDs) exposed to clinical photon and proton beams. We characterized the dose-dependence of the OSL signal, OSL curve shape, and the relative intensities of the blue and ultraviolet (UV) OSL emission bands using different readout protocols and beam qualities. We irradiated OSLDs with absorbed doses ranging from 0.1 Gy to 100 Gy in a 6-MV photon beam and from 0.1 Gy to 50 Gy in 140- and 250-MeV proton beams. Readouts were done with both continuous-wave (CWOSL) and pulsed (POSL) stimulation. The linearity of the OSLD dose–response depended on readout protocol and radiation type. Improved linearity was found for OSLDs irradiated with beams of increased LET, and for OSL signals containing only the blue emission band of Al2 O3 :C (which remained linear for doses up to 10 Gy for 140-MeV proton beam irradiations). The OSL curve shape did not vary with dose in the low-dose region (below 5 Gy depending on readout protocol), but beyond this, curves decayed more rapidly with increasing dose. Similarly, the ratio of blue to UV emission band intensities in the OSL signal did not vary with dose up to 5 Gy (depending on readout protocol), beyond which the ratio decreased with increasing dose. Because both the OSL curve shape and the ratio of blue to UV emission intensities have been investigated asAbstract: In this work we characterized the dose and linear energy transfer (LET) (ionization density) dependence of commercial Al2 O3 :C optically stimulated luminescence (OSL) detectors (OSLDs) exposed to clinical photon and proton beams. We characterized the dose-dependence of the OSL signal, OSL curve shape, and the relative intensities of the blue and ultraviolet (UV) OSL emission bands using different readout protocols and beam qualities. We irradiated OSLDs with absorbed doses ranging from 0.1 Gy to 100 Gy in a 6-MV photon beam and from 0.1 Gy to 50 Gy in 140- and 250-MeV proton beams. Readouts were done with both continuous-wave (CWOSL) and pulsed (POSL) stimulation. The linearity of the OSLD dose–response depended on readout protocol and radiation type. Improved linearity was found for OSLDs irradiated with beams of increased LET, and for OSL signals containing only the blue emission band of Al2 O3 :C (which remained linear for doses up to 10 Gy for 140-MeV proton beam irradiations). The OSL curve shape did not vary with dose in the low-dose region (below 5 Gy depending on readout protocol), but beyond this, curves decayed more rapidly with increasing dose. Similarly, the ratio of blue to UV emission band intensities in the OSL signal did not vary with dose up to 5 Gy (depending on readout protocol), beyond which the ratio decreased with increasing dose. Because both the OSL curve shape and the ratio of blue to UV emission intensities have been investigated as potential parameters for measurements of LET, the constancy of these two quantities at doses relevant to radiotherapy is encouraging for the potential development of novel OSL methods to measure LET. Our findings are expected to contribute to the development of (i) improved readout protocols for commercially available Al2 O3 :C OSLDs and (ii) methods to measure radiation quality and LET. Highlights: OSL curve shape is independent of dose for therapeutic proton doses less than 2 Gy. Blue to UV emission ratio is independent of dose for therapeutic proton doses less than 2 Gy. Range of linear dose response depends on readout mode, signal definition and radiation type. … (more)
- Is Part Of:
- Radiation measurements. Volume 89(2016:Jun.)
- Journal:
- Radiation measurements
- Issue:
- Volume 89(2016:Jun.)
- Issue Display:
- Volume 89 (2016)
- Year:
- 2016
- Volume:
- 89
- Issue Sort Value:
- 2016-0089-0000-0000
- Page Start:
- 35
- Page End:
- 43
- Publication Date:
- 2016-06
- Subjects:
- Optically stimulated luminescence -- Al2O3:C -- Proton therapy -- Linear energy transfer -- Radiation dosimetry
Nuclear emulsions -- Periodicals
Particle tracks (Nuclear physics) -- Periodicals
Thermoluminescence -- Periodicals
Cosmic rays -- Periodicals
Radiation -- Measurement -- Periodicals
Radiometry -- Periodicals
Radiation Monitoring -- Periodicals
Émulsions nucléaires -- Périodiques
Particules (Physique nucléaire) -- Traces -- Périodiques
Thermoluminescence -- Périodiques
Rayonnement cosmique -- Périodiques
Radiométrie -- Périodiques
539.77 - Journal URLs:
- http://www.sciencedirect.com/science/journal/13504487 ↗
http://www.elsevier.com/journals ↗
http://www.journals.elsevier.com/radiation-measurements/ ↗ - DOI:
- 10.1016/j.radmeas.2016.02.002 ↗
- Languages:
- English
- ISSNs:
- 1350-4487
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 7227.973000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 7897.xml