- Abstract: Bacterial infection, a common issue related to orthopedic implantation, is regarded as the second dominant factor resulting in implantation failure. To address the issue, the study reports a novel antibacterial titanium substrate against hyaluronidase secreting bacterium of Staphylococcus aureus, which was fabricated by employing TiO2 nanotubes (TNTs) to load cecropin B (CecB), and then coating with hyaluronidase sensitive multilayers of chitosan/sodium hyaluronic-cecropin B [(Chi/SH–CecB)5 ] onto the titanium surfaces via layer by layer technique (TNT–CecB–LBLc). Fourier transform infrared spectroscopy (FITR) and nuclear magnetic resonance ( 1 H NMR) characterizations proved the successful synthesis of SH–CecB. Scanning electron microscopy (SEM), atomic force microscopy (AFM), fluorescence microscopy and water contact angle measurements verified the formation of multilayers onto CecB loaded titanium substrates. The presence of S. aureus and/or exogenous hyaluronidase effectively triggered the degradation of multilayers, thus facilitating the release of CecB from TNTs. The antibacterial evaluations proved that TNT–CecB–LBLc substrates had good early (4 h) and long term (72 h) antibactericidal capacity against both S. aureus and Staphylococcus epidermidis . Moreover, the cellular tests displayed that TNT–CecB–LBLc substrates had relatively good cytocompatibility for osteoblasts, even co-culture with S. aureus . The study provides new insight into the development ofAbstract: Bacterial infection, a common issue related to orthopedic implantation, is regarded as the second dominant factor resulting in implantation failure. To address the issue, the study reports a novel antibacterial titanium substrate against hyaluronidase secreting bacterium of Staphylococcus aureus, which was fabricated by employing TiO2 nanotubes (TNTs) to load cecropin B (CecB), and then coating with hyaluronidase sensitive multilayers of chitosan/sodium hyaluronic-cecropin B [(Chi/SH–CecB)5 ] onto the titanium surfaces via layer by layer technique (TNT–CecB–LBLc). Fourier transform infrared spectroscopy (FITR) and nuclear magnetic resonance ( 1 H NMR) characterizations proved the successful synthesis of SH–CecB. Scanning electron microscopy (SEM), atomic force microscopy (AFM), fluorescence microscopy and water contact angle measurements verified the formation of multilayers onto CecB loaded titanium substrates. The presence of S. aureus and/or exogenous hyaluronidase effectively triggered the degradation of multilayers, thus facilitating the release of CecB from TNTs. The antibacterial evaluations proved that TNT–CecB–LBLc substrates had good early (4 h) and long term (72 h) antibactericidal capacity against both S. aureus and Staphylococcus epidermidis . Moreover, the cellular tests displayed that TNT–CecB–LBLc substrates had relatively good cytocompatibility for osteoblasts, even co-culture with S. aureus . The study provides new insight into the development of bacteria-mediated antibacterial implants for orthopedic application. Graphical abstract: Highlights: Hyaluronidase sensitive titanium substrates are designed and constructed. Degradation of multilayers is accelerated by hyaluronidase-secreting bacteria. The loaded drug is quickly released once Staphylococcus aureus infection occurs. The above system shows good cytocompatibility and bactericidal ability. … (more)
- Is Part Of:
- Materials & design. Volume 92(2016)
- Journal:
- Materials & design
- Issue:
- Volume 92(2016)
- Issue Display:
- Volume 92, Issue 2016 (2016)
- Year:
- 2016
- Volume:
- 92
- Issue:
- 2016
- Issue Sort Value:
- 2016-0092-2016-0000
- Page Start:
- 1007
- Page End:
- 1017
- Publication Date:
- 2016-02-15
- Subjects:
- TiO2 nanotubes -- Cecropin B -- Osteoblasts -- Staphylococcus aureus -- Co-culture
Materials -- Periodicals
Engineering design -- Periodicals
Matériaux -- Périodiques
Conception technique -- Périodiques
Electronic journals
620.11 - Journal URLs:
- http://catalog.hathitrust.org/api/volumes/oclc/9062775.html ↗
http://www.sciencedirect.com/science/journal/02641275 ↗
http://www.sciencedirect.com/science/journal/02613069 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.matdes.2015.12.126 ↗
- Languages:
- English
- ISSNs:
- 0264-1275
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5393.974000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 7902.xml