Endothelialization of over- and undersized flow-diverter stents at covered vessel side branches: An in vivo and in silico study. Issue 1 (4th January 2016)
- Record Type:
- Journal Article
- Title:
- Endothelialization of over- and undersized flow-diverter stents at covered vessel side branches: An in vivo and in silico study. Issue 1 (4th January 2016)
- Main Title:
- Endothelialization of over- and undersized flow-diverter stents at covered vessel side branches: An in vivo and in silico study
- Authors:
- Berg, Philipp
Iosif, Christina
Ponsonnard, Sebastien
Yardin, Catherine
Janiga, Gábor
Mounayer, Charbel - Abstract:
- Abstract: Although flow-diverting devices are promising treatment options for intracranial aneurysms, jailed side branches might occlude leading to insufficient blood supply. Especially differences in the local stent strut compression may have a drastic influence on subsequent endothelialization. To investigate the outcome of different treatment scenarios, over- and undersized stent deployments were realized experimentally and computationally. Two Pipeline Embolization Devices were placed in the right common carotid artery of large white swine, crossing the right ascending pharyngeal artery. DSA and PC-MRI measurements were acquired pre- and post-stenting and after three months. To evaluate the stent strut endothelialization and the corresponding ostium patency, the swine were sacrificed and scanning electron microscopy measurements were carried out. A more detailed analysis of the near-stent hemodynamics was enabled by a realistic virtual stenting in combination with highly resolved Computational Fluid Dynamics simulations using case-specific boundary conditions. The oversizing resulted in an elongated stent deployment with more open stent pores, while for the undersized case a shorter deployment with more condensed pores was present. In consequence, the side branch of the first case remained patent after three months and the latter almost fully occluded. The virtual investigation confirmed the experimental findings by identifying differences between the individualAbstract: Although flow-diverting devices are promising treatment options for intracranial aneurysms, jailed side branches might occlude leading to insufficient blood supply. Especially differences in the local stent strut compression may have a drastic influence on subsequent endothelialization. To investigate the outcome of different treatment scenarios, over- and undersized stent deployments were realized experimentally and computationally. Two Pipeline Embolization Devices were placed in the right common carotid artery of large white swine, crossing the right ascending pharyngeal artery. DSA and PC-MRI measurements were acquired pre- and post-stenting and after three months. To evaluate the stent strut endothelialization and the corresponding ostium patency, the swine were sacrificed and scanning electron microscopy measurements were carried out. A more detailed analysis of the near-stent hemodynamics was enabled by a realistic virtual stenting in combination with highly resolved Computational Fluid Dynamics simulations using case-specific boundary conditions. The oversizing resulted in an elongated stent deployment with more open stent pores, while for the undersized case a shorter deployment with more condensed pores was present. In consequence, the side branch of the first case remained patent after three months and the latter almost fully occluded. The virtual investigation confirmed the experimental findings by identifying differences between the individual velocities as well as stent shear stresses at the distal part of the ostia. The choice of flow-diverting device and the subsequent deployment strategy strongly influences the patency of jailed side branches. Therefore, careful treatment planning is required, to guarantee sufficient blood supply in the brain territories supplied those branches. … (more)
- Is Part Of:
- Journal of biomechanics. Volume 49:Issue 1(2016)
- Journal:
- Journal of biomechanics
- Issue:
- Volume 49:Issue 1(2016)
- Issue Display:
- Volume 49, Issue 1 (2016)
- Year:
- 2016
- Volume:
- 49
- Issue:
- 1
- Issue Sort Value:
- 2016-0049-0001-0000
- Page Start:
- 4
- Page End:
- 12
- Publication Date:
- 2016-01-04
- Subjects:
- Computational Fluid Dynamics (CFD) -- Endothelialization -- Flow-diverting stent -- Stent shear stress -- Virtual stenting
Animal mechanics -- Periodicals
Biomechanics -- Periodicals
Biomechanics -- Periodicals
Mécanique animale -- Périodiques
Biomécanique -- Périodiques
Electronic journals
571.4305 - Journal URLs:
- http://www.sciencedirect.com/science/journal/00219290 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/00219290 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/00219290 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.jbiomech.2015.10.047 ↗
- Languages:
- English
- ISSNs:
- 0021-9290
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4953.600000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 7895.xml