Robotic Resection of 3 cm and Larger Thymomas Is Associated With Low Perioperative Morbidity and Mortality. Issue 5 (September 2016)
- Record Type:
- Journal Article
- Title:
- Robotic Resection of 3 cm and Larger Thymomas Is Associated With Low Perioperative Morbidity and Mortality. Issue 5 (September 2016)
- Main Title:
- Robotic Resection of 3 cm and Larger Thymomas Is Associated With Low Perioperative Morbidity and Mortality
- Authors:
- Wilshire, Candice L.
Vallières, Eric
Shultz, Dale
Aye, Ralph W.
Farivar, Alexander S.
Louie, Brian E. - Abstract:
- Abstract : Objective: The approach to thymoma resection has usually been determined by tumor size, although established guidelines do not exist. Minimally invasive approaches have been limited to tumors smaller than 5 cm, although 3 cm has been the suggested cutoff for performing an adequate oncologic procedure. No study has compared the perioperative outcomes of patients with 3 cm or larger tumors resected robotically versus sternotomy. Methods: We reviewed patients who underwent resection of 3 cm or larger thymomas from 2004 to 2014. Patients were divided based on approach: robotic and open thymectomy/thymomectomy. Results: Forty patients with tumors ranging from 3 to 13 cm were evaluated, 23 robotic and 17 open. Patient and tumor characteristics were similar. An R0 resection was primarily achieved: robotic, 91% (21/23); and open, 88% (15/17); P = 0.832. Adjuvant radiation rates were statistically equivalent: robotic, 17% (4/23) versus open, 41% (7/17); P = 0.191. Major postoperative complications were comparable: robotic, 4% (1/23) versus open, 29% (4/17); P = 0.184. Median chest tube duration was shorter for robotic (1 day) versus open (3 days); P = 0.001. The robotic approach had a shorter median intensive care unit stay compared to open (0 days vs 1 day); P = 0.024. The median hospital stay was shorter for robotic (2 days) versus open (5 days); P < 0.001. Conclusions: In 3 cm or larger thymomas, robotic thymectomy is feasible based on the ability to achieve a completeAbstract : Objective: The approach to thymoma resection has usually been determined by tumor size, although established guidelines do not exist. Minimally invasive approaches have been limited to tumors smaller than 5 cm, although 3 cm has been the suggested cutoff for performing an adequate oncologic procedure. No study has compared the perioperative outcomes of patients with 3 cm or larger tumors resected robotically versus sternotomy. Methods: We reviewed patients who underwent resection of 3 cm or larger thymomas from 2004 to 2014. Patients were divided based on approach: robotic and open thymectomy/thymomectomy. Results: Forty patients with tumors ranging from 3 to 13 cm were evaluated, 23 robotic and 17 open. Patient and tumor characteristics were similar. An R0 resection was primarily achieved: robotic, 91% (21/23); and open, 88% (15/17); P = 0.832. Adjuvant radiation rates were statistically equivalent: robotic, 17% (4/23) versus open, 41% (7/17); P = 0.191. Major postoperative complications were comparable: robotic, 4% (1/23) versus open, 29% (4/17); P = 0.184. Median chest tube duration was shorter for robotic (1 day) versus open (3 days); P = 0.001. The robotic approach had a shorter median intensive care unit stay compared to open (0 days vs 1 day); P = 0.024. The median hospital stay was shorter for robotic (2 days) versus open (5 days); P < 0.001. Conclusions: In 3 cm or larger thymomas, robotic thymectomy is feasible based on the ability to achieve a complete resection with similar adjuvant radiation therapy rates. Perioperatively, robotic thymectomy is associated with lower morbidity; and shorter chest tube duration, intensive care unit stay, and hospital stay compared to open. However, oncologic outcomes are immature and require prolonged surveillance. … (more)
- Is Part Of:
- Innovations. Volume 11:Issue 5(2016)
- Journal:
- Innovations
- Issue:
- Volume 11:Issue 5(2016)
- Issue Display:
- Volume 11, Issue 5 (2016)
- Year:
- 2016
- Volume:
- 11
- Issue:
- 5
- Issue Sort Value:
- 2016-0011-0005-0000
- Page Start:
- Page End:
- Publication Date:
- 2016-09
- Subjects:
- Robotics -- Video-assisted thoracic surgery (VATS) -- Thymectomy -- Thymoma -- Perioperative outcomes -- Anterior mediastinal mass
Cardiovascular system -- Surgery -- Periodicals
Heart -- Surgery -- Periodicals
Blood-vessels -- Surgery -- Periodicals
Chest -- Surgery -- Periodicals
Thoracic Surgical Procedures -- methods -- Periodicals
Vascular Surgical Procedures -- methods -- Periodicals
Thorax -- Chirurgie -- Méthodologie -- Périodiques
Vaisseaux sanguins -- Chirurgie -- Méthodologie -- Périodiques
Blood-vessels -- Surgery
Chest -- Surgery
Periodicals
617.41 - Journal URLs:
- http://gateway.ovid.com/ovidweb.cgi?T=JS&MODE=ovid&NEWS=n&PAGE=toc&D=ovft&AN=01243895-000000000-00000 ↗
http://journals.lww.com/innovjournal/pages/default.aspx ↗
http://www.lww.com/product/?1556-9845 ↗
http://journals.lww.com/pages/default.aspx ↗ - DOI:
- 10.1097/IMI.0000000000000295 ↗
- Languages:
- English
- ISSNs:
- 1556-9845
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 7909.xml