Performance of two blood culture systems to detect anaerobic bacteria. Is there any difference?. (June 2017)
- Record Type:
- Journal Article
- Title:
- Performance of two blood culture systems to detect anaerobic bacteria. Is there any difference?. (June 2017)
- Main Title:
- Performance of two blood culture systems to detect anaerobic bacteria. Is there any difference?
- Authors:
- Mueller-Premru, Manica
Jeverica, Samo
Papst, Lea
Nagy, Elisabeth - Abstract:
- Abstract: We studied the performance characteristics of two blood culture (BC) bottles/systems, (i) BacT/ALERT-FN Plus/3D (bioMérieux, Marcy l'Étoile, France) and (ii) BACTEC-Lytic/9000 (Becton Dickinson, Sparks, USA) for detection of growth and time-to-positivity (TTP) against a balanced and diverse collection of anaerobic bacterial strains (n = 48) that included reference strains (n = 19) and clinical isolates (n = 29) of 32 species (15 Gram-negative and 17 Gram-positive). Standard suspension of bacteria was inoculated to each bottle in duplicates and incubated in the corresponding system. Overall, 62.5% (n = 30) of strains were detected by both BC bottle types. Comparing the two, 70.8% (n = 34) and 79.2% (n = 38) of strains were detected by BacT/ALERT-FN Plus and BACTEC-Lytic bottles, respectively (p = 0.38). Among Gram-negative anaerobes (n = 25) the detection rate was 76.0% (n = 19) vs. 92.0% (n = 23) (p = 0.22), respectively. Among Gram-positive anaerobes (n = 23) the detection rate was 65.2% (n = 15) in both bottles (p = 1). The average TTP per bottle was calculated only for the strains detected by both systems (n = 30) and was 40.85 h and 28.08 h for BacT/ALERT-FN Plus and BACTEC-Lytic, respectively (p < 0.001). The mean difference was 12.76 h (95% CI: 6.21-19-31 h). Six anaerobic strains were not detected by any system, including Gram-negative Porphyromonas gingivalis, and five Gram-positive strains: Finegoldia magna, Peptostreptococcus anaerobius, PropionibacteriumAbstract: We studied the performance characteristics of two blood culture (BC) bottles/systems, (i) BacT/ALERT-FN Plus/3D (bioMérieux, Marcy l'Étoile, France) and (ii) BACTEC-Lytic/9000 (Becton Dickinson, Sparks, USA) for detection of growth and time-to-positivity (TTP) against a balanced and diverse collection of anaerobic bacterial strains (n = 48) that included reference strains (n = 19) and clinical isolates (n = 29) of 32 species (15 Gram-negative and 17 Gram-positive). Standard suspension of bacteria was inoculated to each bottle in duplicates and incubated in the corresponding system. Overall, 62.5% (n = 30) of strains were detected by both BC bottle types. Comparing the two, 70.8% (n = 34) and 79.2% (n = 38) of strains were detected by BacT/ALERT-FN Plus and BACTEC-Lytic bottles, respectively (p = 0.38). Among Gram-negative anaerobes (n = 25) the detection rate was 76.0% (n = 19) vs. 92.0% (n = 23) (p = 0.22), respectively. Among Gram-positive anaerobes (n = 23) the detection rate was 65.2% (n = 15) in both bottles (p = 1). The average TTP per bottle was calculated only for the strains detected by both systems (n = 30) and was 40.85 h and 28.08 h for BacT/ALERT-FN Plus and BACTEC-Lytic, respectively (p < 0.001). The mean difference was 12.76 h (95% CI: 6.21-19-31 h). Six anaerobic strains were not detected by any system, including Gram-negative Porphyromonas gingivalis, and five Gram-positive strains: Finegoldia magna, Peptostreptococcus anaerobius, Propionibacterium acnes, Clostridium novyi and Clostridium clostridioforme. Furthermore, Eggerthella lenta and Prevotella bivia were detected only by BacT/ALERT-FN Plus, while Prevotella disiens and Prevotella intermedia were detected only by BACTEC-Lytic bottles. There were no major differences in detection rate among clinical and reference strains. Anaerobic bacteria represent a minority of BC isolates, however, far from ideal detection rate was observed in this study for both tested bottle/system combinations. Nevertheless, in those cases where both gave positive signal, BACTEC-Lytic was superior to BacT/ALERT FN Plus with 12.76 h shorter mean TTP. Improvements of media in blood culture bottles available for detection of anaerobes are warranted. Highlights: Suboptimal growth detection of anaerobes was observed in two evaluated blood culture bottles/systems. P. gingivalis, F. magna, P. anaerobius, P. acnes, C. novyi and C. clostridioforme were not detected by the tested systems Time-to-positivity was 12.76 h shorter for resin-free BACTEC-Lytic compared to resin-containing BacT/ALERT-FN Plus bottles … (more)
- Is Part Of:
- Anaerobe. Volume 45(2017)
- Journal:
- Anaerobe
- Issue:
- Volume 45(2017)
- Issue Display:
- Volume 45, Issue 2017 (2017)
- Year:
- 2017
- Volume:
- 45
- Issue:
- 2017
- Issue Sort Value:
- 2017-0045-2017-0000
- Page Start:
- 59
- Page End:
- 64
- Publication Date:
- 2017-06
- Subjects:
- Anaerobe -- Blood culture system -- Detection rate -- Time-to-positivity
Anaerobic infections -- Periodicals
Anaerobic bacteria -- Periodicals
Bacterial diseases -- Periodicals
Computer network resources
Anaerobic protozoa -- Periodicals
579.3 - Journal URLs:
- http://www.sciencedirect.com/science/journal/10759964 ↗
http://firstsearch.oclc.org ↗
http://firstsearch.oclc.org/journal=1075-9964;screen=info;ECOIP ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.anaerobe.2017.03.006 ↗
- Languages:
- English
- ISSNs:
- 1075-9964
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 0859.882000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 7912.xml