In vivo rectal wall measurements during HDR prostate brachytherapy with MOSkin dosimeters integrated on a trans-rectal US probe: Comparison with planned and reconstructed doses. Issue 1 (January 2016)
- Record Type:
- Journal Article
- Title:
- In vivo rectal wall measurements during HDR prostate brachytherapy with MOSkin dosimeters integrated on a trans-rectal US probe: Comparison with planned and reconstructed doses. Issue 1 (January 2016)
- Main Title:
- In vivo rectal wall measurements during HDR prostate brachytherapy with MOSkin dosimeters integrated on a trans-rectal US probe: Comparison with planned and reconstructed doses
- Authors:
- Carrara, Mauro
Tenconi, Chiara
Rossi, Giulio
Borroni, Marta
Cerrotta, Annamaria
Grisotto, Simone
Cusumano, Davide
Pappalardi, Brigida
Cutajar, Dean
Petasecca, Marco
Lerch, Michael
Gambarini, Grazia
Fallai, Carlo
Rosenfeld, Anatoly
Pignoli, Emanuele - Abstract:
- Abstract: Background and purpose: To study if MO Skin detectors coupled to a trans-rectal ultrasound (TRUS) probe may be used for in vivo dosimetry on the rectal wall surface during US-based HDR prostate brachytherapy and to quantify possible discrepancies between planned and delivered doses. Materials and methods: MO Skins are a specific type of MOSFET dosimeter optimized to measure dose in steep dose gradients on interfaces. Two MO Skins were assembled on a TRUS probe used for on-line treatment planning. Measurements of the dose to the rectal wall were performed over 18 treatment sessions and compared to the doses calculated on the pre-treatment plan ( DPRE ) and reconstructed on post-treatment images ( DPOST ). Results: Averages of the absolute differences between MO Skin readings and DPRE, MO Skin readings and DPOST and DPRE and DPOST were 6.7 ± 5.1%, 3.6 ± 1.9% and 6.3 ± 4.7%, respectively. Agreement between measurements and DPOST was significantly better than between measurements and DPRE (p = 0.002) and DPRE and DPOST (p = 0.004). Discrepancy between DPOST and DPRE correlated with the time required for treatment planning. Conclusion: MO Skin dosimeters integrated to the TRUS probe proved to be an accurate instrument for measuring the dose delivered to the rectal wall in HDR prostate brachytherapy. The delivered doses may differ significantly from those calculated in the treatment plan.
- Is Part Of:
- Radiotherapy and oncology. Volume 118:Issue 1(2016:Jan.)
- Journal:
- Radiotherapy and oncology
- Issue:
- Volume 118:Issue 1(2016:Jan.)
- Issue Display:
- Volume 118, Issue 1 (2016)
- Year:
- 2016
- Volume:
- 118
- Issue:
- 1
- Issue Sort Value:
- 2016-0118-0001-0000
- Page Start:
- 148
- Page End:
- 153
- Publication Date:
- 2016-01
- Subjects:
- In vivo dosimetry -- HDR brachytherapy -- Prostate -- MOSFET
Oncology -- Periodicals
Radiotherapy -- Periodicals
Tumors -- Periodicals
Medical Oncology -- Periodicals
Neoplasms -- radiotherapy -- Periodicals
Radiotherapy -- Periodicals
Radiothérapie -- Périodiques
Cancérologie -- Périodiques
Tumeurs -- Périodiques
Electronic journals
616.9940642 - Journal URLs:
- http://www.sciencedirect.com/science/journal/01678140 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/01678140 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/01678140 ↗
http://www.estro.org/ ↗
http://www.elsevier.com/journals ↗
http://www.journals.elsevier.com/radiotherapy-and-oncology/ ↗ - DOI:
- 10.1016/j.radonc.2015.12.022 ↗
- Languages:
- English
- ISSNs:
- 0167-8140
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 7240.790000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 7910.xml