Validation of STA-Liatest D-Di assay for exclusion of pulmonary embolism according to the latest Clinical and Laboratory Standard Institute/Food and Drug Administration guideline. Results of a multicenter management study. Issue 3 (April 2017)
- Record Type:
- Journal Article
- Title:
- Validation of STA-Liatest D-Di assay for exclusion of pulmonary embolism according to the latest Clinical and Laboratory Standard Institute/Food and Drug Administration guideline. Results of a multicenter management study. Issue 3 (April 2017)
- Main Title:
- Validation of STA-Liatest D-Di assay for exclusion of pulmonary embolism according to the latest Clinical and Laboratory Standard Institute/Food and Drug Administration guideline. Results of a multicenter management study
- Authors:
- Pernod, Gilles
Wu, Haifeng
de Maistre, Emmanuel
Lazarchick, John
Kassis, Jeannine
Aguilar, Carlos
Vera, Pascual M.
Palareti, Gualtiero
D'Angelo, Armando - Abstract:
- Abstract : N/A: Combined clinical pretest probability (PTP) and D-dimer testing have great diagnostic value for pulmonary embolism exclusion. To harmonize performance levels of D-dimer assays available on the market, the Clinical and Laboratory Standard Institute (CLSI) has published a guideline, endorsed by the US Food and Drug Administration (FDA). Such guideline specifies the ideal D-dimer assay characteristic and target population. This study was conducted following the CLSI guideline to upgrade the assay-intended use and obtain FDA clearance of STA-Liatest D-Di assay for pulmonary embolism exclusion in patient with low/moderate PTP. This was an international, multicenter, prospective nonrandomized, noninterventional clinical outcome management study conducted in a standard of care setting. D-dimer assay was performed in consecutive, ambulatory outpatients suspected of pulmonary embolism, with low/moderate PTP, and without medical conditions or in clinical settings known to alter default D-dimer values regardless of the presence of thrombosis using a threshold of 0.5 μg/ml (fibrinogen equivalent units) for venous thromboembolism exclusion. Results were used to determine test performance. Of 1141 patients who underwent D-dimer testing, 1060 had valid results and completed study as planned. STA-Liatest D-Di assay performance has exceeded the CLSI/FDA guidance requirements, with a sensitivity of 97.6% (95% confidence interval: 91.7–99.7%) and a negative predictive value ofAbstract : N/A: Combined clinical pretest probability (PTP) and D-dimer testing have great diagnostic value for pulmonary embolism exclusion. To harmonize performance levels of D-dimer assays available on the market, the Clinical and Laboratory Standard Institute (CLSI) has published a guideline, endorsed by the US Food and Drug Administration (FDA). Such guideline specifies the ideal D-dimer assay characteristic and target population. This study was conducted following the CLSI guideline to upgrade the assay-intended use and obtain FDA clearance of STA-Liatest D-Di assay for pulmonary embolism exclusion in patient with low/moderate PTP. This was an international, multicenter, prospective nonrandomized, noninterventional clinical outcome management study conducted in a standard of care setting. D-dimer assay was performed in consecutive, ambulatory outpatients suspected of pulmonary embolism, with low/moderate PTP, and without medical conditions or in clinical settings known to alter default D-dimer values regardless of the presence of thrombosis using a threshold of 0.5 μg/ml (fibrinogen equivalent units) for venous thromboembolism exclusion. Results were used to determine test performance. Of 1141 patients who underwent D-dimer testing, 1060 had valid results and completed study as planned. STA-Liatest D-Di assay performance has exceeded the CLSI/FDA guidance requirements, with a sensitivity of 97.6% (95% confidence interval: 91.7–99.7%) and a negative predictive value of 99.7% (95% confidence interval: 99.0–100%). STA-Liatest D-Di assay has an excellent performance when used in combination with a PTP score in relevant patients and has the potential to minimize the economic healthcare burden avoiding unnecessary and expensive imaging tests. … (more)
- Is Part Of:
- Blood coagulation and fibrinolysis. Volume 28:Issue 3(2017)
- Journal:
- Blood coagulation and fibrinolysis
- Issue:
- Volume 28:Issue 3(2017)
- Issue Display:
- Volume 28, Issue 3 (2017)
- Year:
- 2017
- Volume:
- 28
- Issue:
- 3
- Issue Sort Value:
- 2017-0028-0003-0000
- Page Start:
- Page End:
- Publication Date:
- 2017-04
- Subjects:
- Clinical and Laboratory Standard Institute -- D-dimer -- Food and Drug Administration -- pulmonary embolism -- STA-Liatest D-Di
Blood -- Coagulation -- Periodicals
Fibrinolysis -- Periodicals
Hemostasis -- Periodicals
Thrombosis -- Periodicals
Blood Coagulation -- Periodicals
Fibrinolysis -- Periodicals
Hemostasis -- Periodicals
Thrombosis -- Periodicals
612.115 - Journal URLs:
- http://gateway.ovid.com/ovidweb.cgi?T=JS&MODE=ovid&PAGE=toc&D=ovft&AN=00001721-000000000-00000 ↗
http://www.bloodcoagulation.com/ ↗
http://journals.lww.com/pages/default.aspx ↗
http://firstsearch.oclc.org ↗ - DOI:
- 10.1097/MBC.0000000000000591 ↗
- Languages:
- English
- ISSNs:
- 0957-5235
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 2112.650000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 7889.xml