The six-minute walk test predicts cardiorespiratory fitness in individuals with aneurysmal subarachnoid hemorrhage. Issue 4 (19th May 2017)
- Record Type:
- Journal Article
- Title:
- The six-minute walk test predicts cardiorespiratory fitness in individuals with aneurysmal subarachnoid hemorrhage. Issue 4 (19th May 2017)
- Main Title:
- The six-minute walk test predicts cardiorespiratory fitness in individuals with aneurysmal subarachnoid hemorrhage
- Authors:
- Harmsen, Wouter J.
Ribbers, Gerard M.
Slaman, Jorrit
Heijenbrok-Kal, Majanka H.
Khajeh, Ladbon
van Kooten, Fop
Neggers, Sebastiaan J. C. M. M.
van den Berg-Emons, Rita J. - Abstract:
- Abstract: Background: Peak oxygen uptake (VO2peak ) established during progressive cardiopulmonary exercise testing (CPET) is the "gold-standard" for cardiorespiratory fitness. However, CPET measurements may be limited in patients with aneurysmal subarachnoid hemorrhage (a-SAH) by disease-related complaints, such as cardiovascular health-risks or anxiety. Furthermore, CPET with gas-exchange analyses require specialized knowledge and infrastructure with limited availability in most rehabilitation facilities. Objectives : To determine whether an easy-to-administer six-minute walk test (6MWT) is a valid clinical alternative to progressive CPET in order to predict VO2peak in individuals with a-SAH. Methods: Twenty-seven patients performed the 6MWT and CPET with gas-exchange analyses on a cycle ergometer. Univariate and multivariate regression models were made to investigate the predictability of VO2peak from the six-minute walk distance (6MWD). Results: Univariate regression showed that the 6MWD was strongly related to VO2peak ( r = 0.75, p < 0.001), with an explained variance of 56% and a prediction error of 4.12 ml/kg/min, representing 18% of mean VO2peak . Adding age and sex to an extended multivariate regression model improved this relationship ( r = 0.82, p < 0.001), with an explained variance of 67% and a prediction error of 3.67 ml/kg/min corresponding to 16% of mean VO2peak . Conclusions: The 6MWT is an easy-to-administer submaximal exercise test that can be selectedAbstract: Background: Peak oxygen uptake (VO2peak ) established during progressive cardiopulmonary exercise testing (CPET) is the "gold-standard" for cardiorespiratory fitness. However, CPET measurements may be limited in patients with aneurysmal subarachnoid hemorrhage (a-SAH) by disease-related complaints, such as cardiovascular health-risks or anxiety. Furthermore, CPET with gas-exchange analyses require specialized knowledge and infrastructure with limited availability in most rehabilitation facilities. Objectives : To determine whether an easy-to-administer six-minute walk test (6MWT) is a valid clinical alternative to progressive CPET in order to predict VO2peak in individuals with a-SAH. Methods: Twenty-seven patients performed the 6MWT and CPET with gas-exchange analyses on a cycle ergometer. Univariate and multivariate regression models were made to investigate the predictability of VO2peak from the six-minute walk distance (6MWD). Results: Univariate regression showed that the 6MWD was strongly related to VO2peak ( r = 0.75, p < 0.001), with an explained variance of 56% and a prediction error of 4.12 ml/kg/min, representing 18% of mean VO2peak . Adding age and sex to an extended multivariate regression model improved this relationship ( r = 0.82, p < 0.001), with an explained variance of 67% and a prediction error of 3.67 ml/kg/min corresponding to 16% of mean VO2peak . Conclusions: The 6MWT is an easy-to-administer submaximal exercise test that can be selected to estimate cardiorespiratory fitness at an aggregated level, in groups of patients with a-SAH, which may help to evaluate interventions in a clinical or research setting. However, the relatively large prediction error does not allow for an accurate prediction in individual patients. Abstract : … (more)
- Is Part Of:
- Topics in stroke rehabilitation. Volume 24:Issue 4(2017)
- Journal:
- Topics in stroke rehabilitation
- Issue:
- Volume 24:Issue 4(2017)
- Issue Display:
- Volume 24, Issue 4 (2017)
- Year:
- 2017
- Volume:
- 24
- Issue:
- 4
- Issue Sort Value:
- 2017-0024-0004-0000
- Page Start:
- 250
- Page End:
- 255
- Publication Date:
- 2017-05-19
- Subjects:
- Six-min walk test -- 6MWT -- CPET -- cardiopulmonary exercise test -- cardiorespiratory fitness -- rehabilitation -- VO2peak -- peak oxygen consumption -- standard error of the estimate -- subarachnoid hemorrhage
Cerebrovascular disease -- Patients -- Rehabilitation -- Periodicals
Cerebrovascular disease -- Periodicals
616.810305 - Journal URLs:
- http://thomasland.metapress.com/openurl.asp?genre=journal&issn=1074-9357 ↗
http://www.maneyonline.com/loi/tsr ↗
http://www.tandfonline.com/loi/ytsr20#.V6niC1JTF-V ↗
http://www.maneyonline.com ↗ - DOI:
- 10.1080/10749357.2016.1260263 ↗
- Languages:
- English
- ISSNs:
- 1074-9357
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 8867.490300
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 7904.xml