Efficacy and safety of balloon pulmonary angioplasty for chronic thromboembolic pulmonary hypertension guided by cone-beam computed tomography and electrocardiogram-gated area detector computed tomography. Issue 89 (April 2017)
- Record Type:
- Journal Article
- Title:
- Efficacy and safety of balloon pulmonary angioplasty for chronic thromboembolic pulmonary hypertension guided by cone-beam computed tomography and electrocardiogram-gated area detector computed tomography. Issue 89 (April 2017)
- Main Title:
- Efficacy and safety of balloon pulmonary angioplasty for chronic thromboembolic pulmonary hypertension guided by cone-beam computed tomography and electrocardiogram-gated area detector computed tomography
- Authors:
- Ogo, Takeshi
Fukuda, Tetsuya
Tsuji, Akihiro
Fukui, Shigefumi
Ueda, Jin
Sanda, Yoshihiro
Morita, Yoshiaki
Asano, Ryotaro
Konagai, Nao
Yasuda, Satoshi - Abstract:
- Highlights: Recent advancement in CT enables distal CTEpH lesions to be visualized. We investigated the efficacy and safety of BPA guided by CBCT or ECG-gated area detector CT. BPA guided by CBCT or ECG-gated area detector CT is effective and safe in patients with CTEpH . These new advanced CT techniques may be useful in pre-BPA target lesion assessment. Abstract: Background: Chronic thromboembolic pulmonary hypertension (CTEPH) is a disease characterized by chronic obstructive thrombus and pulmonary hypertension. Balloon pulmonary angioplasty (BPA), an emerging alternative catheter-based treatment for inoperable patients with CTEPH, has not yet been standardised, especially for lesion assessment in distal pulmonary arteries. Recent advancement in computed tomography enables distal CTEPH lesions to be visualized. Methods: We retrospectively studied 80 consecutive patients with inoperable CTEPH who received BPA guided by cone-beam computed tomography (CT) (CBCT) or electrocardiogram (ECG)-gated area detector CT (ADCT) for target lesion assessment. We collected clinical and hemodynamic data, including procedural complications, before BPA and at 3 months and 1 year after BPA. Results: Three hundred eight-five BPA sessions (4.8 sessions/patient) were performed for the lesions of subsegmental arteries (1155 lesions), segmental arteries (738 lesions), and lobar arteries (4 lesions) identified by CBCT or ECG-gated ADCT. Significant improvements in the symptoms, 6-min walk distance,Highlights: Recent advancement in CT enables distal CTEpH lesions to be visualized. We investigated the efficacy and safety of BPA guided by CBCT or ECG-gated area detector CT. BPA guided by CBCT or ECG-gated area detector CT is effective and safe in patients with CTEpH . These new advanced CT techniques may be useful in pre-BPA target lesion assessment. Abstract: Background: Chronic thromboembolic pulmonary hypertension (CTEPH) is a disease characterized by chronic obstructive thrombus and pulmonary hypertension. Balloon pulmonary angioplasty (BPA), an emerging alternative catheter-based treatment for inoperable patients with CTEPH, has not yet been standardised, especially for lesion assessment in distal pulmonary arteries. Recent advancement in computed tomography enables distal CTEPH lesions to be visualized. Methods: We retrospectively studied 80 consecutive patients with inoperable CTEPH who received BPA guided by cone-beam computed tomography (CT) (CBCT) or electrocardiogram (ECG)-gated area detector CT (ADCT) for target lesion assessment. We collected clinical and hemodynamic data, including procedural complications, before BPA and at 3 months and 1 year after BPA. Results: Three hundred eight-five BPA sessions (4.8 sessions/patient) were performed for the lesions of subsegmental arteries (1155 lesions), segmental arteries (738 lesions), and lobar arteries (4 lesions) identified by CBCT or ECG-gated ADCT. Significant improvements in the symptoms, 6-min walk distance, brain natriuretic peptide level, exercise capacity, and haemodynamics were observed 3 months and 1 year after BPA. No cases of death or cardiogenic shock with a low rate of severe wire perforation (0.3%) and severe reperfusion oedema (0.3%) were observed. Conclusions: BPA guided by CBCT or ECG-gated ADCT is effective and remarkably safe in patients with CTEPH . These new advanced CT techniques may be useful in pre-BPA target lesion assessment. … (more)
- Is Part Of:
- European journal of radiology. Issue 89(2017)
- Journal:
- European journal of radiology
- Issue:
- Issue 89(2017)
- Issue Display:
- Volume 89, Issue 89 (2017)
- Year:
- 2017
- Volume:
- 89
- Issue:
- 89
- Issue Sort Value:
- 2017-0089-0089-0000
- Page Start:
- 270
- Page End:
- 276
- Publication Date:
- 2017-04
- Subjects:
- Balloon pulmonary angioplasty -- Chronic thromboembolic pulmonary hypertension -- Cone-beam computed tomography -- ECG-gated area detector computed tomography
Medical radiology -- Periodicals
Radiology -- Periodicals
Radiologie médicale -- Périodiques
Medical radiology
Periodicals
616.075705 - Journal URLs:
- http://www.sciencedirect.com/science/journal/0720048X ↗
http://www.elsevier.com/homepage/elecserv.htt ↗
http://www.clinicalkey.com/dura/browse/journalIssue/0720048X ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/0720048X ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.ejrad.2016.12.013 ↗
- Languages:
- English
- ISSNs:
- 0720-048X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.738050
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 7905.xml