Advanced optimization methods for whole pelvic and local prostate external beam therapy. Issue 3 (March 2016)
- Record Type:
- Journal Article
- Title:
- Advanced optimization methods for whole pelvic and local prostate external beam therapy. Issue 3 (March 2016)
- Main Title:
- Advanced optimization methods for whole pelvic and local prostate external beam therapy
- Authors:
- Buschmann, Martin
Seppenwoolde, Yvette
Wiezorek, Tilo
Weibert, Kirsten
Georg, Dietmar - Abstract:
- Highlights: MCO and conventional optimization were compared in prostate treatment planning. VMAT–MCO and standard VMAT optimization had similar plan quality. Hands-on planning time was reduced considerably with MCO. Whole-pelvic VMAT planning with 2 dose levels is also challenging with MCO. Abstract: Purpose: Radiation treatment planning inherently involves multiple conflicting planning goals, which makes it a suitable application for multicriteria optimization (MCO). This study investigates a MCO algorithm for VMAT planning (VMAT–MCO) for prostate cancer treatments including pelvic lymph nodes and uses standard inverse VMAT optimization (sVMAT) and Tomotherapy planning as benchmarks. Methods: For each of ten prostate cancer patients, a two stage plan was generated, consisting of a stage 1 plan delivering 22 Gy to the prostate, and a stage 2 plan delivering 50.4 Gy to the lymph nodes and 56 Gy to the prostate with a simultaneous integrated boost. The single plans were generated by three planning techniques (VMAT–MCO, sVMAT, Tomotherapy) and subsequently compared with respect to plan quality and planning time efficiency. Results: Plan quality was similar for all techniques, but sVMAT showed slightly better rectum (on average D mean −7%) and bowel sparing ( D mean −17%) compared to VMAT–MCO in the whole pelvic treatments. Tomotherapy plans exhibited higher bladder dose ( D mean +42%) in stage 1 and lower rectum dose ( D mean −6%) in stage 2 than VMAT–MCO. Compared to manualHighlights: MCO and conventional optimization were compared in prostate treatment planning. VMAT–MCO and standard VMAT optimization had similar plan quality. Hands-on planning time was reduced considerably with MCO. Whole-pelvic VMAT planning with 2 dose levels is also challenging with MCO. Abstract: Purpose: Radiation treatment planning inherently involves multiple conflicting planning goals, which makes it a suitable application for multicriteria optimization (MCO). This study investigates a MCO algorithm for VMAT planning (VMAT–MCO) for prostate cancer treatments including pelvic lymph nodes and uses standard inverse VMAT optimization (sVMAT) and Tomotherapy planning as benchmarks. Methods: For each of ten prostate cancer patients, a two stage plan was generated, consisting of a stage 1 plan delivering 22 Gy to the prostate, and a stage 2 plan delivering 50.4 Gy to the lymph nodes and 56 Gy to the prostate with a simultaneous integrated boost. The single plans were generated by three planning techniques (VMAT–MCO, sVMAT, Tomotherapy) and subsequently compared with respect to plan quality and planning time efficiency. Results: Plan quality was similar for all techniques, but sVMAT showed slightly better rectum (on average D mean −7%) and bowel sparing ( D mean −17%) compared to VMAT–MCO in the whole pelvic treatments. Tomotherapy plans exhibited higher bladder dose ( D mean +42%) in stage 1 and lower rectum dose ( D mean −6%) in stage 2 than VMAT–MCO. Compared to manual planning, the planning time with MCO was reduced up to 12 and 38 min for stage 1 and 2 plans, respectively. Conclusion: MCO can generate highly conformal prostate VMAT plans with minimal workload in the settings of prostate-only treatments and prostate plus lymph nodes irradiation. In the whole pelvic plan manual VMAT optimization led to slightly improved OAR sparing over VMAT–MCO, whereas for the primary prostate treatment plan quality was equal. … (more)
- Is Part Of:
- Physica medica. Volume 32:Issue 3(2016)
- Journal:
- Physica medica
- Issue:
- Volume 32:Issue 3(2016)
- Issue Display:
- Volume 32, Issue 3 (2016)
- Year:
- 2016
- Volume:
- 32
- Issue:
- 3
- Issue Sort Value:
- 2016-0032-0003-0000
- Page Start:
- 465
- Page End:
- 473
- Publication Date:
- 2016-03
- Subjects:
- Multicriteria optimization -- Whole-pelvic prostate radiotherapy -- VMAT -- Tomotherapy
Medical physics -- Periodicals
Biophysics -- Periodicals
Biophysics -- Periodicals
Imagerie médicale -- Périodiques
Radiothérapie -- Périodiques
Rayons X -- Sécurité -- Mesures -- Périodiques
Physique -- Périodiques
Médecine -- Périodiques
610.153 - Journal URLs:
- http://www.sciencedirect.com/science/journal/11201797 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/11201797 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/11201797 ↗
http://www.elsevier.com/journals ↗
http://www.physicamedica.com ↗ - DOI:
- 10.1016/j.ejmp.2016.03.002 ↗
- Languages:
- English
- ISSNs:
- 1120-1797
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6475.070000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 7885.xml