MARC prostate treatment planning with Varian Eclipse for flat vs. FFF beams. Issue 3 (March 2016)
- Record Type:
- Journal Article
- Title:
- MARC prostate treatment planning with Varian Eclipse for flat vs. FFF beams. Issue 3 (March 2016)
- Main Title:
- MARC prostate treatment planning with Varian Eclipse for flat vs. FFF beams
- Authors:
- Bell, Katharina
Dzierma, Yvonne
Palm, Jan
Nuesken, Frank
Licht, Norbert
Rübe, Christian - Abstract:
- Highlights: Highly conformal plans could be created with IMRT, mARC, flat and FFF energy. mARC performs better regarding sparing of the bladder. Treatment times could be markedly reduced by using mARC and FFF 7 MV energy. Scattered dose is also decreased by using mARC and FFF 7 MV energy. Abstract: Purpose: The modulated arc (mARC) technique as an alternative to VMAT is a rotational IMRT irradiation with burst mode delivery. Varian has recently implemented an option for mARC-planning into the Eclipse treatment planning system (TPS) and so far mARC-planning with this TPS has not been evaluated systematically. Therefore, for prostate treatment with Eclipse we compare mARC with IMRT using flat (6 MV) and flattening-filter-free (FFF, 7 MV) beam energies. Methods: For ten prostate cancer patients standardized re-contouring and re-planning was performed with a prescription of 76 Gy to the complete planning-target-volume (PTV). IMRT and mARC plans (6 MV vs. FFF 7 MV) were compared pairwise considering indices for plan quality. All plans were delivered on an anthromorphic phantom equipped with thermoluminescent dosimeters to measure out-of-field dose and treatment times. Results: Regarding PTV coverage, there was no marked preference for either technique or energy. The evaluation of organs at risk showed improved bladder sparing of the mARC plans up to about 75 Gy; above this dose the IMRT plans achieved significant better sparing. The use of the FFF-beam-energy and mARC-techniqueHighlights: Highly conformal plans could be created with IMRT, mARC, flat and FFF energy. mARC performs better regarding sparing of the bladder. Treatment times could be markedly reduced by using mARC and FFF 7 MV energy. Scattered dose is also decreased by using mARC and FFF 7 MV energy. Abstract: Purpose: The modulated arc (mARC) technique as an alternative to VMAT is a rotational IMRT irradiation with burst mode delivery. Varian has recently implemented an option for mARC-planning into the Eclipse treatment planning system (TPS) and so far mARC-planning with this TPS has not been evaluated systematically. Therefore, for prostate treatment with Eclipse we compare mARC with IMRT using flat (6 MV) and flattening-filter-free (FFF, 7 MV) beam energies. Methods: For ten prostate cancer patients standardized re-contouring and re-planning was performed with a prescription of 76 Gy to the complete planning-target-volume (PTV). IMRT and mARC plans (6 MV vs. FFF 7 MV) were compared pairwise considering indices for plan quality. All plans were delivered on an anthromorphic phantom equipped with thermoluminescent dosimeters to measure out-of-field dose and treatment times. Results: Regarding PTV coverage, there was no marked preference for either technique or energy. The evaluation of organs at risk showed improved bladder sparing of the mARC plans up to about 75 Gy; above this dose the IMRT plans achieved significant better sparing. The use of the FFF-beam-energy and mARC-technique resulted in a significant decrease in out-of-field dose. This combination also led to a drastic reduction of treatment time by factor of three in comparison with 6 MV IMRT. Conclusion: While highly conformal treatment plans could be created by the use of all modalities, the combination of the high dose rate with mARC appears to be the preferable option as it benefits from a marked decrease in treatment time and out-of-field dose. … (more)
- Is Part Of:
- Physica medica. Volume 32:Issue 3(2016)
- Journal:
- Physica medica
- Issue:
- Volume 32:Issue 3(2016)
- Issue Display:
- Volume 32, Issue 3 (2016)
- Year:
- 2016
- Volume:
- 32
- Issue:
- 3
- Issue Sort Value:
- 2016-0032-0003-0000
- Page Start:
- 474
- Page End:
- 478
- Publication Date:
- 2016-03
- Subjects:
- mARC rotational treatment -- Prostate cancer -- Varian Eclipse treatment planning system -- Flattening-filter-free beam energy
Medical physics -- Periodicals
Biophysics -- Periodicals
Biophysics -- Periodicals
Imagerie médicale -- Périodiques
Radiothérapie -- Périodiques
Rayons X -- Sécurité -- Mesures -- Périodiques
Physique -- Périodiques
Médecine -- Périodiques
610.153 - Journal URLs:
- http://www.sciencedirect.com/science/journal/11201797 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/11201797 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/11201797 ↗
http://www.elsevier.com/journals ↗
http://www.physicamedica.com ↗ - DOI:
- 10.1016/j.ejmp.2016.02.011 ↗
- Languages:
- English
- ISSNs:
- 1120-1797
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6475.070000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 7885.xml