Follow-up of CT-derived airway wall thickness: Correcting for changes in inspiration level improves reliability. Issue 11 (November 2016)
- Record Type:
- Journal Article
- Title:
- Follow-up of CT-derived airway wall thickness: Correcting for changes in inspiration level improves reliability. Issue 11 (November 2016)
- Main Title:
- Follow-up of CT-derived airway wall thickness: Correcting for changes in inspiration level improves reliability
- Authors:
- Pompe, Esther
van Rikxoort, Eva M.
Mets, Onno M.
Charbonnier, Jean-Paul
Kuhnigk, Jan-Martin
de Koning, Harry J.
Oudkerk, Matthijs
Vliegenthart, Rozemarijn
Zanen, Pieter
Lammers, Jan-Willem J.
van Ginneken, Bram
de Jong, Pim A.
Mohamed Hoesein, Firdaus A.A. - Abstract:
- Abstract: Objectives: Airway wall thickness (AWT) is affected by changes in lung volume. This study evaluated whether correcting AWT on computed tomography (CT) for differences in inspiration level improves measurement agreement, reliability, and power to detect changes over time. Methods: Participants of the Dutch-Belgian lung cancer screening trial who underwent 3-month repeat CT for an indeterminate pulmonary nodule were included. AWT on CT was calculated by the square root of the wall area at a theoretical airway with an internal perimeter of 10 mm (Pi10). The scan with the highest lung volume was labelled as the reference scan and the scan with the lowest lung volume was labelled as the comparison scan. Pi10 derived from the comparison scan was corrected by multiplying it with the ratio of CT lung volume of the comparison scan to CT lung volume on the reference scan. Agreement of uncorrected and corrected Pi10 was studied with the Bland-Altman method, reliability with intra-class correlation coefficients (ICC), and power to detect changes over time was calculated. Results: 315 male participants were included. Limit of agreement and reliability for Pi10 was −0.61 to 0.57 mm (ICC = 0.87), which improved to −0.38 to 0.37 mm (ICC = 0.94) after correction for inspiration level. To detect a 15% change over 3 months, 71 subjects are needed for Pi10 and 26 subjects for Pi10 adjusted for inspiration level. Conclusions: Correcting Pi10 for differences in inspiration levelAbstract: Objectives: Airway wall thickness (AWT) is affected by changes in lung volume. This study evaluated whether correcting AWT on computed tomography (CT) for differences in inspiration level improves measurement agreement, reliability, and power to detect changes over time. Methods: Participants of the Dutch-Belgian lung cancer screening trial who underwent 3-month repeat CT for an indeterminate pulmonary nodule were included. AWT on CT was calculated by the square root of the wall area at a theoretical airway with an internal perimeter of 10 mm (Pi10). The scan with the highest lung volume was labelled as the reference scan and the scan with the lowest lung volume was labelled as the comparison scan. Pi10 derived from the comparison scan was corrected by multiplying it with the ratio of CT lung volume of the comparison scan to CT lung volume on the reference scan. Agreement of uncorrected and corrected Pi10 was studied with the Bland-Altman method, reliability with intra-class correlation coefficients (ICC), and power to detect changes over time was calculated. Results: 315 male participants were included. Limit of agreement and reliability for Pi10 was −0.61 to 0.57 mm (ICC = 0.87), which improved to −0.38 to 0.37 mm (ICC = 0.94) after correction for inspiration level. To detect a 15% change over 3 months, 71 subjects are needed for Pi10 and 26 subjects for Pi10 adjusted for inspiration level. Conclusions: Correcting Pi10 for differences in inspiration level improves reliability, agreement, and power to detect changes over time. … (more)
- Is Part Of:
- European journal of radiology. Volume 85:Issue 11(2016)
- Journal:
- European journal of radiology
- Issue:
- Volume 85:Issue 11(2016)
- Issue Display:
- Volume 85, Issue 11 (2016)
- Year:
- 2016
- Volume:
- 85
- Issue:
- 11
- Issue Sort Value:
- 2016-0085-0011-0000
- Page Start:
- 2008
- Page End:
- 2013
- Publication Date:
- 2016-11
- Subjects:
- AWT airway wall thickness -- COPD chronic obstructive pulmonary disease -- CT computed tomography -- ICC intra-class correlation coefficient -- Pi10 theoretical airway with an internal parameter of 10 mm -- SD standard deviation
Airway wall thickness -- Computed tomography -- Follow-up -- Lung volume -- Reliability
Medical radiology -- Periodicals
Radiology -- Periodicals
Radiologie médicale -- Périodiques
Medical radiology
Periodicals
616.075705 - Journal URLs:
- http://www.sciencedirect.com/science/journal/0720048X ↗
http://www.elsevier.com/homepage/elecserv.htt ↗
http://www.clinicalkey.com/dura/browse/journalIssue/0720048X ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/0720048X ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.ejrad.2016.09.009 ↗
- Languages:
- English
- ISSNs:
- 0720-048X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.738050
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 7866.xml