Approximation of Resting Energy Expenditure in Intensive Care Unit Patients Using the SenseWear Bracelet: A Comparison With Indirect Calorimetry. (August 2017)
- Record Type:
- Journal Article
- Title:
- Approximation of Resting Energy Expenditure in Intensive Care Unit Patients Using the SenseWear Bracelet: A Comparison With Indirect Calorimetry. (August 2017)
- Main Title:
- Approximation of Resting Energy Expenditure in Intensive Care Unit Patients Using the SenseWear Bracelet: A Comparison With Indirect Calorimetry
- Authors:
- Sundström, Martin
Mehrabi, Mahboubeh
Tjäder, Inga
Rooyackers, Olav
Hammarqvist, Folke - Abstract:
- Background and Aims: Indirect calorimetry (IC) is the gold standard for determining energy expenditure in patients requiring mechanical ventilation. Metabolic armbands using data derived from dermal measurements have been proposed as an alternative to IC in healthy subjects, but their utility during critical illness is unclear. The aim of this study was to determine the level of agreement between the SenseWear armband and the Deltatrac Metabolic Monitor in mechanically ventilated intensive care unit (ICU) patients. Methods: Adult ICU patients requiring invasive ventilator therapy were eligible for inclusion. Simultaneous measurements were performed with the SenseWear Armband and Deltatrac under stable conditions. Resting energy expenditure (REE) values were registered for both instruments and compared with Bland-Altman plots. Results: Forty-two measurements were performed in 30 patients. The SenseWear Armband measured significantly higher REE values as compared with IC (mean bias, 85 kcal/24 h; P = .027). Less variability was noted between individual SenseWear measurements and REE as predicted by the Harris-Benedict equation (2 SD, ±327 kcal/24 h) than when IC was compared with SenseWear and Harris-Benedict (2 SD, ±473 and ±543 kcal/24 h, respectively). Conclusions: The systematic bias and large variability of the SenseWear armband when compared with gas exchange measurements confer limited benefits over the Harris Benedict equation in determining caloric requirements of ICUBackground and Aims: Indirect calorimetry (IC) is the gold standard for determining energy expenditure in patients requiring mechanical ventilation. Metabolic armbands using data derived from dermal measurements have been proposed as an alternative to IC in healthy subjects, but their utility during critical illness is unclear. The aim of this study was to determine the level of agreement between the SenseWear armband and the Deltatrac Metabolic Monitor in mechanically ventilated intensive care unit (ICU) patients. Methods: Adult ICU patients requiring invasive ventilator therapy were eligible for inclusion. Simultaneous measurements were performed with the SenseWear Armband and Deltatrac under stable conditions. Resting energy expenditure (REE) values were registered for both instruments and compared with Bland-Altman plots. Results: Forty-two measurements were performed in 30 patients. The SenseWear Armband measured significantly higher REE values as compared with IC (mean bias, 85 kcal/24 h; P = .027). Less variability was noted between individual SenseWear measurements and REE as predicted by the Harris-Benedict equation (2 SD, ±327 kcal/24 h) than when IC was compared with SenseWear and Harris-Benedict (2 SD, ±473 and ±543 kcal/24 h, respectively). Conclusions: The systematic bias and large variability of the SenseWear armband when compared with gas exchange measurements confer limited benefits over the Harris Benedict equation in determining caloric requirements of ICU patients. … (more)
- Is Part Of:
- JPEN, Journal of parenteral and enteral nutrition. Volume 41:Number 6(2017)
- Journal:
- JPEN, Journal of parenteral and enteral nutrition
- Issue:
- Volume 41:Number 6(2017)
- Issue Display:
- Volume 41, Issue 6 (2017)
- Year:
- 2017
- Volume:
- 41
- Issue:
- 6
- Issue Sort Value:
- 2017-0041-0006-0000
- Page Start:
- 976
- Page End:
- 980
- Publication Date:
- 2017-08
- Subjects:
- energy expenditure -- nutrition -- intensive care unit -- indirect calorimetry -- SenseWear -- Deltatrac
Parenteral feeding -- Periodicals
Enteral feeding -- Periodicals
615.85484 - Journal URLs:
- http://pen.sagepub.com/ ↗
http://www.sagepublications.com/ ↗ - DOI:
- 10.1177/0148607116633808 ↗
- Languages:
- English
- ISSNs:
- 0148-6071
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5029.100000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 7849.xml