In Vivo Ultrasound Characteristics of Vaginal Mesh Kit Complications. Issue 2 (March 2017)
- Record Type:
- Journal Article
- Title:
- In Vivo Ultrasound Characteristics of Vaginal Mesh Kit Complications. Issue 2 (March 2017)
- Main Title:
- In Vivo Ultrasound Characteristics of Vaginal Mesh Kit Complications
- Authors:
- Javadian, Pouya
Quiroz, Lieschen H.
Shobeiri, S. Abbas - Abstract:
- Abstract : Objective: The objective of this study was to investigate the ultrasound characteristics of vaginal mesh in women with vaginal mesh complications. Methods: This was a cross-sectional study of women presenting with extrusion complications from vaginal mesh kit for prolapse at our tertiary care center between years 2009 and 2014. We included women who concurrently underwent a 3-dimensional endovaginal ultrasound (EVUS) as part of the clinical evaluation. We excluded women with incomplete charts and poor imaging quality. Subjects were categorized by the presence or absence of associated pelvic pain. Based on ultrasound findings, we compared the location of mesh, the appearance of mesh pattern (flat, folding, prominence, convoluted), and other EVUS characteristics of mesh. Results: Forty-six women with vaginal mesh complications and good image quality were included. When comparing mesh length between posterior and anterior compartments, the posterior meshes were significantly longer than the anterior meshes (42.1 [SD, 11.9] mm vs 25.8 [SD, 9] mm; P < 0.0001) and more often associated with pain. In the posterior compartment, the mean mesh length seen on EVUS was significantly longer in women with pain than in women without pain (46.5 [SD, 9] mm vs 31.8 [SD, 12.1] mm; P = 0.0001). There was also a higher proportion of a "flat" mesh pattern, 14 (58.3%) of 25, in the posterior compartment associated with the presence of pain ( P = 0.013). In the posterior compartment, aAbstract : Objective: The objective of this study was to investigate the ultrasound characteristics of vaginal mesh in women with vaginal mesh complications. Methods: This was a cross-sectional study of women presenting with extrusion complications from vaginal mesh kit for prolapse at our tertiary care center between years 2009 and 2014. We included women who concurrently underwent a 3-dimensional endovaginal ultrasound (EVUS) as part of the clinical evaluation. We excluded women with incomplete charts and poor imaging quality. Subjects were categorized by the presence or absence of associated pelvic pain. Based on ultrasound findings, we compared the location of mesh, the appearance of mesh pattern (flat, folding, prominence, convoluted), and other EVUS characteristics of mesh. Results: Forty-six women with vaginal mesh complications and good image quality were included. When comparing mesh length between posterior and anterior compartments, the posterior meshes were significantly longer than the anterior meshes (42.1 [SD, 11.9] mm vs 25.8 [SD, 9] mm; P < 0.0001) and more often associated with pain. In the posterior compartment, the mean mesh length seen on EVUS was significantly longer in women with pain than in women without pain (46.5 [SD, 9] mm vs 31.8 [SD, 12.1] mm; P = 0.0001). There was also a higher proportion of a "flat" mesh pattern, 14 (58.3%) of 25, in the posterior compartment associated with the presence of pain ( P = 0.013). In the posterior compartment, a smaller distance between the distal edge of the mesh and the anal sphincter was significantly associated with the presence of pain (8 mm [0–37] vs 21 mm [8–35], P = 0.024). In both compartments, the EVUS had 100% sensitivity for detection of mesh extrusions. Conclusions: In this population of patients presenting with mesh complications, the posterior meshes were more often visualized as a "flat" pattern with a higher frequency of pain. Mesh complications of the anterior compartment had a higher frequency of folding and shrinkage. Abstract : In this 3-dimensional endovaginal ultrasound study of patients presenting with mesh complications, the posterior meshes were more often visualized as a "flat" pattern with a higher frequency of pain, and the mesh complications of the anterior compartment had a higher frequency of folding and shrinkage. … (more)
- Is Part Of:
- Female pelvic medicine & reconstructive surgery. Volume 23:Issue 2(2017)
- Journal:
- Female pelvic medicine & reconstructive surgery
- Issue:
- Volume 23:Issue 2(2017)
- Issue Display:
- Volume 23, Issue 2 (2017)
- Year:
- 2017
- Volume:
- 23
- Issue:
- 2
- Issue Sort Value:
- 2017-0023-0002-0000
- Page Start:
- Page End:
- Publication Date:
- 2017-03
- Subjects:
- endovaginal ultrasound -- pelvic organ prolapse -- vaginal mesh -- complication
Pelvis -- Diseases -- Periodicals
Pelvis -- Surgery -- Periodicals
Genital Diseases, Female -- surgery -- Periodicals
Urologic Diseases -- surgery -- Periodicals
Colonic Diseases -- surgery -- Periodicals
Rectal Diseases -- surgery -- Periodicals
Surgical Procedures, Operative -- methods -- Periodicals
616.6 - Journal URLs:
- http://gateway.ovid.com/ovidweb.cgi?T=JS&MODE=ovid&PAGE=toc&D=ovft&AN=01436319-000000000-00000 ↗
http://journals.lww.com/jpelvicsurgery/pages/default.aspx ↗
http://www.jpelvicsurgery.com ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/SPV.0000000000000400 ↗
- Languages:
- English
- ISSNs:
- 2151-8378
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3905.168400
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 7864.xml