Chirp- and random-based coded ultrasonic excitation for localized blood-brain barrier opening. (22nd September 2015)
- Record Type:
- Journal Article
- Title:
- Chirp- and random-based coded ultrasonic excitation for localized blood-brain barrier opening. (22nd September 2015)
- Main Title:
- Chirp- and random-based coded ultrasonic excitation for localized blood-brain barrier opening
- Authors:
- Kamimura, H A S
Wang, S
Wu, S-Y
Karakatsani, M E
Acosta, C
Carneiro, A A O
Konofagou, E E - Abstract:
- Abstract: Chirp- and random-based coded excitation methods have been proposed to reduce standing wave formation and improve focusing of transcranial ultrasound. However, no clear evidence has been shown to support the benefits of these ultrasonic excitation sequences in vivo . This study evaluates the chirp and periodic selection of random frequency (PSRF) coded-excitation methods for opening the blood-brain barrier (BBB) in mice. Three groups of mice ( n = 15) were injected with polydisperse microbubbles and sonicated in the caudate putamen using the chirp/PSRF coded (bandwidth: 1.5–1.9 MHz, peak negative pressure: 0.52 MPa, duration: 30 s) or standard ultrasound (frequency: 1.5 MHz, pressure: 0.52 MPa, burst duration: 20 ms, duration: 5 min) sequences. T1-weighted contrast-enhanced MRI scans were performed to quantitatively analyze focused ultrasound induced BBB opening. The mean opening volumes evaluated from the MRI were mm 3, mm 3 and mm 3 for the chirp, random and regular sonications, respectively. The mean cavitation levels were V.s, V.s and V.s for the chirp, random and regular sonications, respectively. The chirp and PSRF coded pulsing sequences improved the BBB opening localization by inducing lower cavitation levels and smaller opening volumes compared to results of the regular sonication technique. Larger bandwidths were associated with more focused targeting but were limited by the frequency response of the transducer, the skull attenuation and theAbstract: Chirp- and random-based coded excitation methods have been proposed to reduce standing wave formation and improve focusing of transcranial ultrasound. However, no clear evidence has been shown to support the benefits of these ultrasonic excitation sequences in vivo . This study evaluates the chirp and periodic selection of random frequency (PSRF) coded-excitation methods for opening the blood-brain barrier (BBB) in mice. Three groups of mice ( n = 15) were injected with polydisperse microbubbles and sonicated in the caudate putamen using the chirp/PSRF coded (bandwidth: 1.5–1.9 MHz, peak negative pressure: 0.52 MPa, duration: 30 s) or standard ultrasound (frequency: 1.5 MHz, pressure: 0.52 MPa, burst duration: 20 ms, duration: 5 min) sequences. T1-weighted contrast-enhanced MRI scans were performed to quantitatively analyze focused ultrasound induced BBB opening. The mean opening volumes evaluated from the MRI were mm 3, mm 3 and mm 3 for the chirp, random and regular sonications, respectively. The mean cavitation levels were V.s, V.s and V.s for the chirp, random and regular sonications, respectively. The chirp and PSRF coded pulsing sequences improved the BBB opening localization by inducing lower cavitation levels and smaller opening volumes compared to results of the regular sonication technique. Larger bandwidths were associated with more focused targeting but were limited by the frequency response of the transducer, the skull attenuation and the microbubbles optimal frequency range. The coded methods could therefore facilitate highly localized drug delivery as well as benefit other transcranial ultrasound techniques that use higher pressure levels and higher precision to induce the necessary bioeffects in a brain region while avoiding damage to the surrounding healthy tissue. … (more)
- Is Part Of:
- Physics in medicine & biology. Volume 60:Number 19(2015:Oct.)
- Journal:
- Physics in medicine & biology
- Issue:
- Volume 60:Number 19(2015:Oct.)
- Issue Display:
- Volume 60, Issue 19 (2015)
- Year:
- 2015
- Volume:
- 60
- Issue:
- 19
- Issue Sort Value:
- 2015-0060-0019-0000
- Page Start:
- 7695
- Page End:
- 7712
- Publication Date:
- 2015-09-22
- Subjects:
- blood-brain barrier opening -- chirp -- coded ultrasonic excitation -- focused ultrasound -- standing wave -- transcranial ultrasound
Biophysics -- Periodicals
Medical physics -- Periodicals
610.153 - Journal URLs:
- http://ioppublishing.org/ ↗
http://iopscience.iop.org/0031-9155 ↗ - DOI:
- 10.1088/0031-9155/60/19/7695 ↗