Towards geometrical calibration of x-ray computed tomography systems—a review. (19th August 2015)
- Record Type:
- Journal Article
- Title:
- Towards geometrical calibration of x-ray computed tomography systems—a review. (19th August 2015)
- Main Title:
- Towards geometrical calibration of x-ray computed tomography systems—a review
- Authors:
- Ferrucci, Massimiliano
Leach, Richard K
Giusca, Claudiu
Carmignato, Simone
Dewulf, Wim - Abstract:
- Abstract: Industrial x-ray computed tomography (XCT) is seen as a potentially effective tool for the industrial inspection of complex parts. In particular, XCT is an attractive solution for the measurement of internal geometries, which are inaccessible by conventional coordinate measuring systems. While the technology is available and the benefits are recognized, methods to establish the measurement assurance of XCT systems are lacking. More specifically, the assessment of measurement uncertainty and the subsequent establishment of measurement traceability is a largely unknown process. This paper is a review of research that contributes to the development of a geometrical calibration procedure for XCT systems. A brief introduction to the geometry of cone-beam tomography systems is given, after which the geometrical influence factors are outlined. Mathematical measurement models play a significant role in understanding how geometrical offsets and misalignments contribute to error in measurements; therefore, the application of mathematical models in simulating geometrical errors is discussed and the corresponding literature is presented. Then, the various methods that have been developed to measure certain geometrical errors are reviewed. The findings from this review are discussed and suggestions are provided for future work towards the development of a comprehensive and practical geometrical calibration procedure.
- Is Part Of:
- Measurement science & technology. Volume 26:Number 9(2015:Sep.)
- Journal:
- Measurement science & technology
- Issue:
- Volume 26:Number 9(2015:Sep.)
- Issue Display:
- Volume 26, Issue 9 (2015)
- Year:
- 2015
- Volume:
- 26
- Issue:
- 9
- Issue Sort Value:
- 2015-0026-0009-0000
- Page Start:
- Page End:
- Publication Date:
- 2015-08-19
- Subjects:
- x-ray computed tomography -- geometrical calibration -- dimensional metrology
Physical measurements -- Periodicals
Scientific apparatus and instruments -- Periodicals
Equipment and Supplies -- Periodicals
Science -- instrumentation -- Periodicals
Technology -- instrumentation -- Periodicals
Mesures physiques -- Périodiques
Physical measurements
Scientific apparatus and instruments
Periodicals
502.87 - Journal URLs:
- http://iopscience.iop.org/0957-0233/ ↗
http://www.iop.org/Journals/mt ↗
http://ioppublishing.org/ ↗ - DOI:
- 10.1088/0957-0233/26/9/092003 ↗
- Languages:
- English
- ISSNs:
- 0957-0233
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 7807.xml