Effect of jet length and ambient temperature on the performance of a two-phase jet impingement heat sink refrigeration system. (March 2017)
- Record Type:
- Journal Article
- Title:
- Effect of jet length and ambient temperature on the performance of a two-phase jet impingement heat sink refrigeration system. (March 2017)
- Main Title:
- Effect of jet length and ambient temperature on the performance of a two-phase jet impingement heat sink refrigeration system
- Authors:
- de Oliveira, Pablo A.
Barbosa, Jader R. - Abstract:
- Highlights: A novel jet-based heat sink integrates the evaporator and the expansion device. The system was tested with a small-scale oil-free R-134a compressor. Effects of piston stroke, thermal load, jet length and ambient temperature were evaluated. System was evaluated based on COP, heat transfer coefficient (h) and heater temperature (TS ). Decreasing the jet length reduced the CHF; increasing Tamb increased h. Abstract: The jet impingement heat sink integrated with a compact oil-free R-134a vapor compression refrigeration system introduced in a previous work (Oliveira and Barbosa, 2017 ) is now further evaluated in terms of the influence of the compressor piston stroke, applied thermal load, orifice-to-heater distance (jet length) and ambient (hot end) temperature. The proposed heat sink is a compact active thermal solution for concentrated heat loads because it integrates the evaporator and the expansion device into a single unit, making use of a single two-phase impinging jet as the cooling mechanism. The present analysis is based on the coefficient of performance and other steady-state heat transfer parameters associated with the impinging jet (heat transfer coefficient and heater surface temperature). A reduction of the jet length promoted a more vigorous splattering of the jet on the heated surface, enhancing the droplet breakup, which in turn reduced significantly the critical heat flux. An increase of the hot reservoir temperature increased the jet impingementHighlights: A novel jet-based heat sink integrates the evaporator and the expansion device. The system was tested with a small-scale oil-free R-134a compressor. Effects of piston stroke, thermal load, jet length and ambient temperature were evaluated. System was evaluated based on COP, heat transfer coefficient (h) and heater temperature (TS ). Decreasing the jet length reduced the CHF; increasing Tamb increased h. Abstract: The jet impingement heat sink integrated with a compact oil-free R-134a vapor compression refrigeration system introduced in a previous work (Oliveira and Barbosa, 2017 ) is now further evaluated in terms of the influence of the compressor piston stroke, applied thermal load, orifice-to-heater distance (jet length) and ambient (hot end) temperature. The proposed heat sink is a compact active thermal solution for concentrated heat loads because it integrates the evaporator and the expansion device into a single unit, making use of a single two-phase impinging jet as the cooling mechanism. The present analysis is based on the coefficient of performance and other steady-state heat transfer parameters associated with the impinging jet (heat transfer coefficient and heater surface temperature). A reduction of the jet length promoted a more vigorous splattering of the jet on the heated surface, enhancing the droplet breakup, which in turn reduced significantly the critical heat flux. An increase of the hot reservoir temperature increased the jet impingement heat transfer coefficient. … (more)
- Is Part Of:
- International journal of refrigeration. Volume 75(2017)
- Journal:
- International journal of refrigeration
- Issue:
- Volume 75(2017)
- Issue Display:
- Volume 75, Issue 2017 (2017)
- Year:
- 2017
- Volume:
- 75
- Issue:
- 2017
- Issue Sort Value:
- 2017-0075-2017-0000
- Page Start:
- 331
- Page End:
- 342
- Publication Date:
- 2017-03
- Subjects:
- Jet impingement -- Vapor compression -- Compact system -- Oil-free compressor -- Electronics cooling
Collision de jet -- Compression de vapeur -- Système compact -- Compresseur sans huile -- Refroidissement d'électronique
Refrigeration and refrigerating machinery -- Periodicals
621.56 - Journal URLs:
- http://www.elsevier.com/journals ↗
http://www.sciencedirect.com/science/journal/aip/01407007 ↗ - DOI:
- 10.1016/j.ijrefrig.2017.01.001 ↗
- Languages:
- English
- ISSNs:
- 0140-7007
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4542.525500
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 7795.xml