Control of fault lay-out on seismic design of large underground caverns. (August 2015)
- Record Type:
- Journal Article
- Title:
- Control of fault lay-out on seismic design of large underground caverns. (August 2015)
- Main Title:
- Control of fault lay-out on seismic design of large underground caverns
- Authors:
- Ardeshiri-Lajimi, Saeid
Yazdani, Mahmoud
Assadi Langroudi, Arya - Abstract:
- Highlights: Fault affects caverns' seismic stability by extending the plastic zone and strains. A 40–50° dip, single-point-intersection-on-crown k 0 = 1 fault layout is critical. For seismic loading, critical limit state occurs when fault passes heel and sidewall. For faults passing crown, k 0 = 0.5, collapse likelihood is directly correlated with dip. Collapse is less likely with increasing dip for a k 0 = 0.5 fault passing heel & sidewall. Abstract: Although buried structures are generally believed to suffer a lesser degree of damage in the event of earthquake – than that of over-ground structures – significant damage has been widely reported to buried assets after major earthquakes, including the 1995 Kobe and the 2008 Wen-Chuan. Discontinuity is one key feature of rock as the supporting medium around subsurface excavated spaces. Joints, faults and bedding planes influence, by-and-large, the stability of structures made from/into rock. In particular, fault system around underground caverns such as hydropower house has a marked control on assets' seismic stability. This study builds on the current understanding through vigorous numerical modelling of fault-structure system under seismic excitation. A parametric approach is followed to determine the most critical layout of a single fault crossing a benchmark cavern. Fault system is systematically broken down into several combinations of dips and intersection points with cavern wall. For each case, a nonlinear dynamicHighlights: Fault affects caverns' seismic stability by extending the plastic zone and strains. A 40–50° dip, single-point-intersection-on-crown k 0 = 1 fault layout is critical. For seismic loading, critical limit state occurs when fault passes heel and sidewall. For faults passing crown, k 0 = 0.5, collapse likelihood is directly correlated with dip. Collapse is less likely with increasing dip for a k 0 = 0.5 fault passing heel & sidewall. Abstract: Although buried structures are generally believed to suffer a lesser degree of damage in the event of earthquake – than that of over-ground structures – significant damage has been widely reported to buried assets after major earthquakes, including the 1995 Kobe and the 2008 Wen-Chuan. Discontinuity is one key feature of rock as the supporting medium around subsurface excavated spaces. Joints, faults and bedding planes influence, by-and-large, the stability of structures made from/into rock. In particular, fault system around underground caverns such as hydropower house has a marked control on assets' seismic stability. This study builds on the current understanding through vigorous numerical modelling of fault-structure system under seismic excitation. A parametric approach is followed to determine the most critical layout of a single fault crossing a benchmark cavern. Fault system is systematically broken down into several combinations of dips and intersection points with cavern wall. For each case, a nonlinear dynamic analysis is conducted. To simulate the discontinuous medium, the hybrid finite difference – discrete element code CA2 (Continuum Analysis 2 dimensional) is implemented. The work showed that, similar to static conditions, fault influences the seismic stability of underground caverns through a tendency in extending the plastic zones and increasing displacements as well as asymmetric distribution of the latter and the former in rock medium. A 40–50° dip, single-point-intersection-on-crown k 0 = 1 fault layout renders the most critical combination from both ultimate and serviceability limit states perspective. Under earthquake loading conditions however, the critical limit states condition took place for single fault intersected the cavern at heel and sidewall. The latter critical condition led to the tensile failure of cavern right sidewall. For faults intersecting the carven crown and having a k 0 = 0.5, collapse would be more likely as fault dip increases. Collapse would be less likely with increasing dip for k 0 = 0.5 fault crossing the bed and sidewall of caverns. … (more)
- Is Part Of:
- Tunnelling and underground space technology. Volume 50(2015)
- Journal:
- Tunnelling and underground space technology
- Issue:
- Volume 50(2015)
- Issue Display:
- Volume 50, Issue 2015 (2015)
- Year:
- 2015
- Volume:
- 50
- Issue:
- 2015
- Issue Sort Value:
- 2015-0050-2015-0000
- Page Start:
- 305
- Page End:
- 316
- Publication Date:
- 2015-08
- Subjects:
- Fault -- Underground -- Plastic zone -- Serviceability -- Seismic
Tunneling -- Periodicals
Underground construction -- Periodicals
Tunnels -- Periodicals
Underground areas -- Periodicals
624.193 - Journal URLs:
- http://www.sciencedirect.com/science/journal/08867798 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.tust.2015.07.002 ↗
- Languages:
- English
- ISSNs:
- 0886-7798
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 9071.405000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 7780.xml