The optimum design and arrangement of a steam generator in an integral pressurized water reactor. (March 2016)
- Record Type:
- Journal Article
- Title:
- The optimum design and arrangement of a steam generator in an integral pressurized water reactor. (March 2016)
- Main Title:
- The optimum design and arrangement of a steam generator in an integral pressurized water reactor
- Authors:
- Wei, Xinyu
Dai, Chunhui
Wang, Pengfei
Zhao, Fuyu - Abstract:
- Highlights: A double-tube once-through steam generator (DOTSG) for IPWR is proposed. Optimum structure of inner helical tube and arrangement of DOTSGs are obtained. Two-level optimization method is used for the lower pumping power and smaller RPV. The pitch should be smaller in single-phase region than that in boiling region. N sg and N d are optimized for obtain the minimum volume of the IPWR. Abstract: This paper presents a double-tube once-through steam generator (DOTSG), whose tube unit includes an outer straight tube and an inner helical tube, in an integral pressurized water reactor (IPWR). To obtain the optimum structure of the inner helical tube and the arrangement of DOTSGs in the reactor pressure vessel, a two-level optimization method is used, aiming at the lower pumping power needed, and a smaller reactor pressure vessel volume is used. The pitch of inner helical tubes and the central distance of outer tubes are considered design parameters when minimizing the pumping power with the genetic algorithm in the bottom level, while the number of tube units in a single DOTSG and the number of DOTSGs in the reactor pressure vessel (RPV) are optimized to obtain the minimum volume of the IPWR, which is conducted in the top level. The optimum pitch of the helical tube varies in the sub-cooled region, boiling region and superheated region. The results show that the smaller pitch brings a shorter tube length and a higher pressure drop, and the effects are strong in theHighlights: A double-tube once-through steam generator (DOTSG) for IPWR is proposed. Optimum structure of inner helical tube and arrangement of DOTSGs are obtained. Two-level optimization method is used for the lower pumping power and smaller RPV. The pitch should be smaller in single-phase region than that in boiling region. N sg and N d are optimized for obtain the minimum volume of the IPWR. Abstract: This paper presents a double-tube once-through steam generator (DOTSG), whose tube unit includes an outer straight tube and an inner helical tube, in an integral pressurized water reactor (IPWR). To obtain the optimum structure of the inner helical tube and the arrangement of DOTSGs in the reactor pressure vessel, a two-level optimization method is used, aiming at the lower pumping power needed, and a smaller reactor pressure vessel volume is used. The pitch of inner helical tubes and the central distance of outer tubes are considered design parameters when minimizing the pumping power with the genetic algorithm in the bottom level, while the number of tube units in a single DOTSG and the number of DOTSGs in the reactor pressure vessel (RPV) are optimized to obtain the minimum volume of the IPWR, which is conducted in the top level. The optimum pitch of the helical tube varies in the sub-cooled region, boiling region and superheated region. The results show that the smaller pitch brings a shorter tube length and a higher pressure drop, and the effects are strong in the sub-cooled region and the superheated region but weak in the boiling region. In this way, the optimal structure of the inner helical tube is a small pitch in the single-phase region and a large pitch in the boiling region. According to the bottom level results, the optimum arrangement of DOTSGs in the pressure vessel is determined. … (more)
- Is Part Of:
- International journal of heat and mass transfer. Volume 94(2016:Mar.)
- Journal:
- International journal of heat and mass transfer
- Issue:
- Volume 94(2016:Mar.)
- Issue Display:
- Volume 94 (2016)
- Year:
- 2016
- Volume:
- 94
- Issue Sort Value:
- 2016-0094-0000-0000
- Page Start:
- 211
- Page End:
- 221
- Publication Date:
- 2016-03
- Subjects:
- Double-tube once-through steam generator (DOTSG) -- Pitch -- Arrangement -- Two-level optimization method
Heat -- Transmission -- Periodicals
Mass transfer -- Periodicals
Chaleur -- Transmission -- Périodiques
Transfert de masse -- Périodiques
Electronic journals
621.4022 - Journal URLs:
- http://www.sciencedirect.com/science/journal/00179310 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.ijheatmasstransfer.2015.11.070 ↗
- Languages:
- English
- ISSNs:
- 0017-9310
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4542.280000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 7774.xml