Importance of the left ventricular outflow tract in the need for pacemaker implantation after transcatheter aortic valve replacement. (1st August 2016)
- Record Type:
- Journal Article
- Title:
- Importance of the left ventricular outflow tract in the need for pacemaker implantation after transcatheter aortic valve replacement. (1st August 2016)
- Main Title:
- Importance of the left ventricular outflow tract in the need for pacemaker implantation after transcatheter aortic valve replacement
- Authors:
- Rodríguez-Olivares, Ramón
van Gils, Lennart
El Faquir, Nahid
Rahhab, Zouhair
Di Martino, Luigi F.M.
van Weenen, Sander
de Vries, John
Galema, Tjebbe W.
Geleijnse, Marcel L.
Budde, Ricardo P.J.
Boersma, Eric
de Jaegere, Peter P.
Van Mieghem, Nicolas M. - Abstract:
- Abstract: Background: The interaction of left ventricular outflow tract (LVOT) and transcatheter heart valve (THV) is complex and may be device design specific. We sought to study LVOT characteristics and its relation with permanent pacemaker implantation (PPI) after transcatheter aortic valve replacement (TAVR). Methods: We studied 302 patients with a median age of 81 years [75–84]. Computed tomography was used to assess LVOT in terms of amount of calcium, perimeter and device size relative to LVOT. Results: We implanted a Medtronic CoreValve (MCS) in 203 patients, Edwards-Sapien XT (ESV-XT) in 38, Edwards-Sapien S3 (ESV-S3) in 26 and Lotus in 35 patients. Sixty-eight patients (22.5%) received a new PPI within 30 days after the index procedure. The incidence of PPI was 22.7% with MCS, 10.5% with ESV-XT, 26.9% with ESV-S3 and 31.4% with Lotus. By multivariate analysis RBBB at baseline (OR 2.9 [1.2–6.9, p = 0.014), second generation valves (OR 2.1 [1.0–4.5], p = 0.048), DOI (OR 1.20 per 1 mm increment, [1.09–1.31], p < 0.001) and LVOT sizing (OR per 1% increment 1.03 [1.01–1.07], p = 0.022) were associated with need for PPI. Sensitivity analyses suggest that a lesser degree of LVOT oversizing triggers PPI with second generation THVs vs. first generation THVs. Conclusions: More LVOT oversizing is associated with a higher need for permanent pacemaker implantation after TAVR, even more so with deeper THV implants and next generation devices (ESV-S3 and Lotus). Sizing algorithmsAbstract: Background: The interaction of left ventricular outflow tract (LVOT) and transcatheter heart valve (THV) is complex and may be device design specific. We sought to study LVOT characteristics and its relation with permanent pacemaker implantation (PPI) after transcatheter aortic valve replacement (TAVR). Methods: We studied 302 patients with a median age of 81 years [75–84]. Computed tomography was used to assess LVOT in terms of amount of calcium, perimeter and device size relative to LVOT. Results: We implanted a Medtronic CoreValve (MCS) in 203 patients, Edwards-Sapien XT (ESV-XT) in 38, Edwards-Sapien S3 (ESV-S3) in 26 and Lotus in 35 patients. Sixty-eight patients (22.5%) received a new PPI within 30 days after the index procedure. The incidence of PPI was 22.7% with MCS, 10.5% with ESV-XT, 26.9% with ESV-S3 and 31.4% with Lotus. By multivariate analysis RBBB at baseline (OR 2.9 [1.2–6.9, p = 0.014), second generation valves (OR 2.1 [1.0–4.5], p = 0.048), DOI (OR 1.20 per 1 mm increment, [1.09–1.31], p < 0.001) and LVOT sizing (OR per 1% increment 1.03 [1.01–1.07], p = 0.022) were associated with need for PPI. Sensitivity analyses suggest that a lesser degree of LVOT oversizing triggers PPI with second generation THVs vs. first generation THVs. Conclusions: More LVOT oversizing is associated with a higher need for permanent pacemaker implantation after TAVR, even more so with deeper THV implants and next generation devices (ESV-S3 and Lotus). Sizing algorithms should focus more on LVOT dimensions to reduce PPI. … (more)
- Is Part Of:
- International journal of cardiology. Volume 216(2016)
- Journal:
- International journal of cardiology
- Issue:
- Volume 216(2016)
- Issue Display:
- Volume 216, Issue 2016 (2016)
- Year:
- 2016
- Volume:
- 216
- Issue:
- 2016
- Issue Sort Value:
- 2016-0216-2016-0000
- Page Start:
- 9
- Page End:
- 15
- Publication Date:
- 2016-08-01
- Subjects:
- Aortic stenosis -- Transcatheter aortic valve implantation -- Pacemaker implantation -- Multi-slice computed tomography -- Left ventricular outflow tract
Cardiology -- Periodicals
Electronic journals
616.12 - Journal URLs:
- http://www.clinicalkey.com/dura/browse/journalIssue/01675273 ↗
http://www.sciencedirect.com/science/journal/01675273 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.ijcard.2016.04.023 ↗
- Languages:
- English
- ISSNs:
- 0167-5273
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4542.158000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 7798.xml