Biomechanical comparison of expanded polytetrafluoroethylene (ePTFE) and PTFE interpositional patches and direct tendon-to-bone repair for massive rotator cuff tears in an ovine model. Issue 1 (January 2016)
- Record Type:
- Journal Article
- Title:
- Biomechanical comparison of expanded polytetrafluoroethylene (ePTFE) and PTFE interpositional patches and direct tendon-to-bone repair for massive rotator cuff tears in an ovine model. Issue 1 (January 2016)
- Main Title:
- Biomechanical comparison of expanded polytetrafluoroethylene (ePTFE) and PTFE interpositional patches and direct tendon-to-bone repair for massive rotator cuff tears in an ovine model
- Authors:
- McKeown, Andrew DJ
Beattie, Rebekah F
Murrell, George AC
Lam, Patrick H - Abstract:
- Background: Massive irreparable rotator cuff tears are a difficult problem. Modalities such as irrigation and debridement, partial repair, tendon transfer and grafts have been utilized with high failure rates and mixed results. Synthetic interpositional patch repairs are a novel and increasingly used approach. The present study aimed to examine the biomechanical properties of common synthetic materials for interpositional repairs in contrast to native tendon. Methods: Six ovine tendons, six polytetrafluoroethylene (PTFE) felt sections and six expanded PTFE (ePTFE) patch sections were pulled-to-failure to analyze their biomechanical and material properties. Six direct tendon-to-bone surgical method repairs, six interpositional PTFE felt patch repairs and six interpositional ePTFE patch repairs were also constructed in ovine shoulders and pulled-to-failure to examine the biomechanical properties of each repair construct. Results: Ovine tendon had higher load-to-failure (591 N) and had greater stiffness (108 N/mm) than either PTFE felt (296 N, 28 N/mm) or ePTFE patch sections (323 N, 34 N/mm). Both PTFE felt and ePTFE repair techniques required greater load-to-failure (225 N and 177 N, respectively) than direct tendon-to-bone surgical repairs (147 N) in ovine models. Conclusions: Synthetic materials lacked several biomechanical properties, including strength and stiffness, compared to ovine tendon. Interpositional surgical repair models with these materials were significantlyBackground: Massive irreparable rotator cuff tears are a difficult problem. Modalities such as irrigation and debridement, partial repair, tendon transfer and grafts have been utilized with high failure rates and mixed results. Synthetic interpositional patch repairs are a novel and increasingly used approach. The present study aimed to examine the biomechanical properties of common synthetic materials for interpositional repairs in contrast to native tendon. Methods: Six ovine tendons, six polytetrafluoroethylene (PTFE) felt sections and six expanded PTFE (ePTFE) patch sections were pulled-to-failure to analyze their biomechanical and material properties. Six direct tendon-to-bone surgical method repairs, six interpositional PTFE felt patch repairs and six interpositional ePTFE patch repairs were also constructed in ovine shoulders and pulled-to-failure to examine the biomechanical properties of each repair construct. Results: Ovine tendon had higher load-to-failure (591 N) and had greater stiffness (108 N/mm) than either PTFE felt (296 N, 28 N/mm) or ePTFE patch sections (323 N, 34 N/mm). Both PTFE felt and ePTFE repair techniques required greater load-to-failure (225 N and 177 N, respectively) than direct tendon-to-bone surgical repairs (147 N) in ovine models. Conclusions: Synthetic materials lacked several biomechanical properties, including strength and stiffness, compared to ovine tendon. Interpositional surgical repair models with these materials were significantly stronger than direct tendon-to-bone model repairs. … (more)
- Is Part Of:
- Shoulder & elbow. Volume 8:Issue 1(2016)
- Journal:
- Shoulder & elbow
- Issue:
- Volume 8:Issue 1(2016)
- Issue Display:
- Volume 8, Issue 1 (2016)
- Year:
- 2016
- Volume:
- 8
- Issue:
- 1
- Issue Sort Value:
- 2016-0008-0001-0000
- Page Start:
- 22
- Page End:
- 31
- Publication Date:
- 2016-01
- Subjects:
- biomechanics -- interpositional patch -- irreparable rotator cuff -- ovine -- PTFE patch -- synthetic patch repair
Elbow -- Diseases -- Periodicals
Elbow -- Surgery -- Periodicals
Shoulder -- Diseases -- Periodicals
Shoulder -- Surgery -- Periodicals
Shoulder -- Periodicals
Elbow -- Periodicals
Shoulder Joint -- Periodicals
Elbow Joint -- Periodicals
617.572005 - Journal URLs:
- http://ejournals.ebsco.com/direct.asp?JournalID=718387 ↗
http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1758-5740 ↗
http://journals.sagepub.com/home/sel ↗
http://www.uk.sagepub.com/home.nav ↗ - DOI:
- 10.1177/1758573215601815 ↗
- Languages:
- English
- ISSNs:
- 1758-5732
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 7741.xml