Incorporating the effect of fractionation in the evaluation of proton plan robustness to setup errors. (16th December 2015)
- Record Type:
- Journal Article
- Title:
- Incorporating the effect of fractionation in the evaluation of proton plan robustness to setup errors. (16th December 2015)
- Main Title:
- Incorporating the effect of fractionation in the evaluation of proton plan robustness to setup errors
- Authors:
- Lowe, Matthew
Albertini, Francesca
Aitkenhead, Adam
Lomax, Antony J
MacKay, Ranald I - Abstract:
- Abstract: To ensure the safe delivery of proton therapy treatments it is important to evaluate the effect of potential uncertainties, such as patient mispositioning, on the intended dose distribution. However, it can be expected that the uncertainty resulting from patient positioning is reduced in a fractionated treatment due to the convergence of random variables with the delivery of repeated treatments. This is neglected by current approaches to robustness analysis resulting in an overly conservative assessment of the robustness which can lead to sub-optimal plans. Here, a fast method of accounting for this reduced uncertainty is presented. An estimated bound to the error in the dose distribution resulting from setup uncertainty over a specified number of fractions is calculated by considering the distribution of values for each voxel across 14 initial error scenarios. The bound on the error in a given voxel is estimated using a 99.9% confidence limit assuming a convergence towards a normal distribution in line with the central limit theorem, and a correction of accounting for the reduction in the standard deviation over n fractions. The proposed method was validated in 5 patients by comparison to Monte Carlo simulations of 300 treatment courses. A voxelwise and volumetric analysis of the estimated and simulated bounds to the uncertainty in the dose distribution demonstrate that the proposed technique can be used to assess proton plan robustness more accurately allowingAbstract: To ensure the safe delivery of proton therapy treatments it is important to evaluate the effect of potential uncertainties, such as patient mispositioning, on the intended dose distribution. However, it can be expected that the uncertainty resulting from patient positioning is reduced in a fractionated treatment due to the convergence of random variables with the delivery of repeated treatments. This is neglected by current approaches to robustness analysis resulting in an overly conservative assessment of the robustness which can lead to sub-optimal plans. Here, a fast method of accounting for this reduced uncertainty is presented. An estimated bound to the error in the dose distribution resulting from setup uncertainty over a specified number of fractions is calculated by considering the distribution of values for each voxel across 14 initial error scenarios. The bound on the error in a given voxel is estimated using a 99.9% confidence limit assuming a convergence towards a normal distribution in line with the central limit theorem, and a correction of accounting for the reduction in the standard deviation over n fractions. The proposed method was validated in 5 patients by comparison to Monte Carlo simulations of 300 treatment courses. A voxelwise and volumetric analysis of the estimated and simulated bounds to the uncertainty in the dose distribution demonstrate that the proposed technique can be used to assess proton plan robustness more accurately allowing for less conservative treatment plans. … (more)
- Is Part Of:
- Physics in medicine & biology. Volume 61:Number 1(2016:Jan.)
- Journal:
- Physics in medicine & biology
- Issue:
- Volume 61:Number 1(2016:Jan.)
- Issue Display:
- Volume 61, Issue 1 (2016)
- Year:
- 2016
- Volume:
- 61
- Issue:
- 1
- Issue Sort Value:
- 2016-0061-0001-0000
- Page Start:
- 413
- Page End:
- 429
- Publication Date:
- 2015-12-16
- Subjects:
- proton therapy -- robustness -- uncertainty
Biophysics -- Periodicals
Medical physics -- Periodicals
610.153 - Journal URLs:
- http://ioppublishing.org/ ↗
http://iopscience.iop.org/0031-9155 ↗ - DOI:
- 10.1088/0031-9155/61/1/413 ↗
- Languages:
- English
- ISSNs:
- 0031-9155
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 7747.xml