Colorimetric detection of hydrogen peroxide and glucose using brominated graphene. Issue 47 (23rd November 2017)
- Record Type:
- Journal Article
- Title:
- Colorimetric detection of hydrogen peroxide and glucose using brominated graphene. Issue 47 (23rd November 2017)
- Main Title:
- Colorimetric detection of hydrogen peroxide and glucose using brominated graphene
- Authors:
- Singh, Shikha
Mitra, Kheyanath
Singh, Rajshree
Kumari, Archana
Sen Gupta, Susanta Kumar
Misra, Nira
Maiti, Pralay
Ray, Biswajit - Abstract:
- Abstract : Colorimetric detection of hydrogen peroxide and glucose using brominated graphene in the presence of 3, 3′, 5, 5′-tetramethylbenzidine (TMB). Abstract : Very recently, we have reported a novel peroxidase mimetic material, brominated graphene (GBR) having ∼3% bromine content, which, in combination with H2 O2 and 3, 3′, 5, 5′-tetramethylbenzidine (TMB), has shown the property of S 2− ion recognition ( Anal. Chem., 2017, 89, 783–791). In the present work, we further have investigated the kinetic assay and colorimetric sensing ability of GBR towards hydrogen peroxide (H2 O2 ) and glucose. The Michaelis–Menten constants ( K m ) and maximum initial velocities ( V max ) of GBR have been found to be 10.98 mM and 3.60 × 10 −8 M s −1, respectively, for H2 O2 and 0.83 mM and 0.68 × 10 −8 M s −1, respectively, for TMB. A sensor combining TMB and GBR has been fabricated, which, upon addition to H2 O2 or glucose with glucose oxidase solution at pH 4.48, showed colorimetrically a significant increase in the oxidation of TMB. The fabricated sensor system has displayed linearity for H2 O2 and glucose estimation in the range 0.50–5.00 mM and 40–100 mM, respectively, and the corresponding limits of detection are found to be 0.417 and 28.41 mM, respectively. The present sensor system is also highly reproducible and selective. The results of real samples using this colorimetric method have been found to be comparable with the conventional auto-analyser method.
- Is Part Of:
- Analytical methods. Volume 9:Issue 47(2017)
- Journal:
- Analytical methods
- Issue:
- Volume 9:Issue 47(2017)
- Issue Display:
- Volume 9, Issue 47 (2017)
- Year:
- 2017
- Volume:
- 9
- Issue:
- 47
- Issue Sort Value:
- 2017-0009-0047-0000
- Page Start:
- 6675
- Page End:
- 6681
- Publication Date:
- 2017-11-23
- Subjects:
- Chemistry, Analytic -- Periodicals
Analytical biochemistry -- Periodicals
Chemical laboratories -- Standards -- Periodicals
543.1905 - Journal URLs:
- http://pubs.rsc.org/en/Journals/JournalIssues/AY ↗
http://www.rsc.org/ ↗ - DOI:
- 10.1039/c7ay02212c ↗
- Languages:
- English
- ISSNs:
- 1759-9660
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 0897.103700
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 7719.xml