Dot enzyme‐linked immunosorbent assay strip as a screening tool for detection of autoantibody to interferon gamma in sera of suspected cases of adult‐onset immunodeficiency. Issue 7 (22nd April 2018)
- Record Type:
- Journal Article
- Title:
- Dot enzyme‐linked immunosorbent assay strip as a screening tool for detection of autoantibody to interferon gamma in sera of suspected cases of adult‐onset immunodeficiency. Issue 7 (22nd April 2018)
- Main Title:
- Dot enzyme‐linked immunosorbent assay strip as a screening tool for detection of autoantibody to interferon gamma in sera of suspected cases of adult‐onset immunodeficiency
- Authors:
- Rattanathammethee, Kritsadee
Chawansuntati, Kriangkrai
Chaiwarith, Romanee
Praparattanapan, Jutarat
Supparatpinyo, Khuanchai
Wipasa, Jiraprapa - Abstract:
- Abstract : Background: Being able to detect the presence of autoantibodies to interferon (IFN)‐γ in serum is essential for evaluating patients with suspected adult‐onset immunodeficiency (AOID) with unusual intracellular infections. Most reported patients with AOID have been Asian, although the exact prevalence of this illness is unknown. To date, no standard assay exists to detect autoantibodies to IFN‐γ. An easy‐to‐use, low‐cost assay that can be performed in any laboratory would be a valuable tool for clinical management of AOID, as well as better reveal its prevalence. Methods: Our experimental study exploited a dot enzyme‐linked immunosorbent assay (Dot‐ELISA) strip to detect autoantibodies to IFN‐γ. Sera from 66 HIV‐negative patients having autoantibodies to IFN‐γ as determined by indirect ELISA were tested. Results: Dot enzyme‐linked immunosorbent assay was sensitive (100%) and specific (94.5%), with a positive predictive value of 97.6% and a negative predictive value of 100%. Conclusion: This simple method provides prompt qualitative results that can be read visually and used in facilities with limited testing capabilities.
- Is Part Of:
- Journal of clinical laboratory analysis. Volume 32:Issue 7(2018)
- Journal:
- Journal of clinical laboratory analysis
- Issue:
- Volume 32:Issue 7(2018)
- Issue Display:
- Volume 32, Issue 7 (2018)
- Year:
- 2018
- Volume:
- 32
- Issue:
- 7
- Issue Sort Value:
- 2018-0032-0007-0000
- Page Start:
- n/a
- Page End:
- n/a
- Publication Date:
- 2018-04-22
- Subjects:
- adult‐onset immunodeficiency -- autoantibody -- dot enzyme‐linked immunosorbent assay -- interferon gamma -- screening
Diagnosis, Laboratory -- Periodicals
Medical laboratory technology -- Periodicals
616 - Journal URLs:
- http://onlinelibrary.wiley.com/ ↗
- DOI:
- 10.1002/jcla.22460 ↗
- Languages:
- English
- ISSNs:
- 0887-8013
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4958.520000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 7715.xml