Prospective, randomized comparison of 3‐dimensional computed tomography guidance versus TEE data for left atrial appendage occlusion (PRO3DLAAO). Issue 2 (1st February 2018)
- Record Type:
- Journal Article
- Title:
- Prospective, randomized comparison of 3‐dimensional computed tomography guidance versus TEE data for left atrial appendage occlusion (PRO3DLAAO). Issue 2 (1st February 2018)
- Main Title:
- Prospective, randomized comparison of 3‐dimensional computed tomography guidance versus TEE data for left atrial appendage occlusion (PRO3DLAAO)
- Authors:
- Eng, Marvin H.
Wang, Dee Dee
Greenbaum, Adam B.
Gheewala, Neil
Kupsky, Daniel
Aka, Tongwa
Song, Thomas
Kendall, Bradley James
Wyman, Janet
Myers, Eric
Forbes, Michael
O'Neill, William W. - Abstract:
- Abstract: Background: Preliminary data comparing 3‐dimensional computed tomography (3D‐CT) to transesophageal echocardiography (TEE) for left atrial appendage occlusion (LAAO) indicates that 3D‐CT provides more accurate measurements and improves case planning. Therefore, we conducted a pilot study comparing 3D‐CT to TEE in occluder selection accuracy and procedural efficiency. Methods: From May 2016 to February 2017, 24 patients were prospectively randomized to undergo LAAO using either TEE or 3D‐CT. The primary endpoint was device accuracy while the secondary endpoints included # devices per case, # guide catheters used per case, # fluoroscopy angles used, procedure time, fluoroscopy time, radiation dose, and major adverse events (stroke, MI, device embolization, perforation, death). Results: Procedure success was 100% and 92% for the 3D‐CT and 2D‐TEE cohorts respectively. Accuracy for 1st device selection 92% and 27% ( P = .01) for 3D‐CT and 2D‐TEE respectively but with intra‐procedural upsizing in the 2D‐TEE cohort, the 2D‐TEE cohort accuracy increased to 64% while the 3D‐CT groups 92% was accurate ( P = .33). Case planning using 3D‐CT was significantly more efficient with respect to device utilization (CT 1.33 ± 0.7 vs. 2D‐TEE 2.5 ± 1.2 P = .01), guide catheters (CT 1 vs. 2D‐TEE 1.7 ± 0.8 P = .01) and procedure time (3D‐CT 55 ± 17 min vs. 2D‐TEE 73 ± 24 min P < .05). One major adverse event, a stroke occurred in the 2D‐TEE group. Conclusion: In this single‐centerAbstract: Background: Preliminary data comparing 3‐dimensional computed tomography (3D‐CT) to transesophageal echocardiography (TEE) for left atrial appendage occlusion (LAAO) indicates that 3D‐CT provides more accurate measurements and improves case planning. Therefore, we conducted a pilot study comparing 3D‐CT to TEE in occluder selection accuracy and procedural efficiency. Methods: From May 2016 to February 2017, 24 patients were prospectively randomized to undergo LAAO using either TEE or 3D‐CT. The primary endpoint was device accuracy while the secondary endpoints included # devices per case, # guide catheters used per case, # fluoroscopy angles used, procedure time, fluoroscopy time, radiation dose, and major adverse events (stroke, MI, device embolization, perforation, death). Results: Procedure success was 100% and 92% for the 3D‐CT and 2D‐TEE cohorts respectively. Accuracy for 1st device selection 92% and 27% ( P = .01) for 3D‐CT and 2D‐TEE respectively but with intra‐procedural upsizing in the 2D‐TEE cohort, the 2D‐TEE cohort accuracy increased to 64% while the 3D‐CT groups 92% was accurate ( P = .33). Case planning using 3D‐CT was significantly more efficient with respect to device utilization (CT 1.33 ± 0.7 vs. 2D‐TEE 2.5 ± 1.2 P = .01), guide catheters (CT 1 vs. 2D‐TEE 1.7 ± 0.8 P = .01) and procedure time (3D‐CT 55 ± 17 min vs. 2D‐TEE 73 ± 24 min P < .05). One major adverse event, a stroke occurred in the 2D‐TEE group. Conclusion: In this single‐center pilot study, CT guided LAAO case planning was associated with improved device selection accuracy and procedural efficiency. This study data supports the notion that comprehensive 3D assessment significantly simplifies LAAO, minimizing the time and number of steps needed. … (more)
- Is Part Of:
- Catheterization and cardiovascular interventions. Volume 92:Issue 2(2018)
- Journal:
- Catheterization and cardiovascular interventions
- Issue:
- Volume 92:Issue 2(2018)
- Issue Display:
- Volume 92, Issue 2 (2018)
- Year:
- 2018
- Volume:
- 92
- Issue:
- 2
- Issue Sort Value:
- 2018-0092-0002-0000
- Page Start:
- 401
- Page End:
- 407
- Publication Date:
- 2018-02-01
- Subjects:
- 3D printing -- CT -- left atrial appendage occlusion -- Watchman™
Heart -- Diseases -- Diagnosis -- Periodicals
Cardiac catheterization -- Periodicals
616.1207572 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-726X ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/ccd.27514 ↗
- Languages:
- English
- ISSNs:
- 1522-1946
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3092.992000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 7688.xml