Intraoperative 2D C-arm and 3D O-arm in children: a comparative phantom study. (1st October 2018)
- Record Type:
- Journal Article
- Title:
- Intraoperative 2D C-arm and 3D O-arm in children: a comparative phantom study. (1st October 2018)
- Main Title:
- Intraoperative 2D C-arm and 3D O-arm in children: a comparative phantom study
- Authors:
- Prod'homme, M.
Sans-Merce, M.
Pitteloud, N.
Damet, J.
Lascombes, P. - Abstract:
- Abstract: Purpose: Exposure to ionizing radiation is a concern for children during intraoperative imaging. We aimed to assess the radiation exposure to the paediatric patient with 2D and 3D imaging. Methods: To evaluate the radiation exposure, patient absorbed doses to the organs were measured in an anthropomorphic phantom representing a five-year-old child, using thermoluminescent dosimeters. For comparative purposes, organ doses were measured using a C-arm for one minute of fluoroscopy and one acquisition with an O-arm. The cone-beam was centred on the pelvis. Direct and scattered irradiations were measured and compared (Student's t -test). Skin entrance dose rates were also evaluated. Results: All radiation doses were expressed in µGy. Direct radiation doses of pelvic organs were between 631.22 and 1691.87 for the O-arm and between 214.08 and 737.51 for the C-arm, and were not significant (p = 0.07). Close scattered radiation on abdominal organs were between 25.11 and 114.85 for the O-arm and between 8.03 and 55.34 for the C-arm, and were not significant (p = 0.07). Far scattered radiation doses on thorax, neck and head varied from 0.86 to 6.42 for the O-arm and from 0.04 to 3.08 for the C-arm, and were significant (p = 0.02). The dose rate at the skin entrance was 328.58 µGy.s −1 for the O-arm and 1.90 with the C-arm. Conclusion: During imaging of the pelvis, absorbed doses for a 3D O-arm acquisition were higher than with one minute fluoroscopy with the C-arm. FurtherAbstract: Purpose: Exposure to ionizing radiation is a concern for children during intraoperative imaging. We aimed to assess the radiation exposure to the paediatric patient with 2D and 3D imaging. Methods: To evaluate the radiation exposure, patient absorbed doses to the organs were measured in an anthropomorphic phantom representing a five-year-old child, using thermoluminescent dosimeters. For comparative purposes, organ doses were measured using a C-arm for one minute of fluoroscopy and one acquisition with an O-arm. The cone-beam was centred on the pelvis. Direct and scattered irradiations were measured and compared (Student's t -test). Skin entrance dose rates were also evaluated. Results: All radiation doses were expressed in µGy. Direct radiation doses of pelvic organs were between 631.22 and 1691.87 for the O-arm and between 214.08 and 737.51 for the C-arm, and were not significant (p = 0.07). Close scattered radiation on abdominal organs were between 25.11 and 114.85 for the O-arm and between 8.03 and 55.34 for the C-arm, and were not significant (p = 0.07). Far scattered radiation doses on thorax, neck and head varied from 0.86 to 6.42 for the O-arm and from 0.04 to 3.08 for the C-arm, and were significant (p = 0.02). The dose rate at the skin entrance was 328.58 µGy.s −1 for the O-arm and 1.90 with the C-arm. Conclusion: During imaging of the pelvis, absorbed doses for a 3D O-arm acquisition were higher than with one minute fluoroscopy with the C-arm. Further clinical studies comparing effective doses are needed to assess ionizing risks of the intraoperative imaging systems in children. … (more)
- Is Part Of:
- Journal of children's orthopaedics. Volume 12:Number 5(2018)
- Journal:
- Journal of children's orthopaedics
- Issue:
- Volume 12:Number 5(2018)
- Issue Display:
- Volume 12, Issue 5 (2018)
- Year:
- 2018
- Volume:
- 12
- Issue:
- 5
- Issue Sort Value:
- 2018-0012-0005-0000
- Page Start:
- 550
- Page End:
- 557
- Publication Date:
- 2018-10-01
- Subjects:
- ionizing radiations -- CBCT -- O-arm -- paediatric orthopaedics -- patient exposure
Pediatric orthopedics -- Periodicals
618.927005 - Journal URLs:
- http://link.springer.com/journal/11832 ↗
http://www.ncbi.nlm.nih.gov/pmc/journals/842/ ↗
http://www.springerlink.com/content/120451/ ↗
https://online.boneandjoint.org.uk/toc/jco/current ↗
https://journals.sagepub.com/home/CHO ↗
http://www.springer.com/gb/ ↗ - DOI:
- 10.1302/1863-2548.12.180016 ↗
- Languages:
- English
- ISSNs:
- 1863-2521
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4957.960000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 7685.xml