A Semiautomated Method for Measuring the 3-Dimensional Fabric to Renal Artery Distances to Determine Endograft Position After Endovascular Aneurysm Repair. (October 2017)
- Record Type:
- Journal Article
- Title:
- A Semiautomated Method for Measuring the 3-Dimensional Fabric to Renal Artery Distances to Determine Endograft Position After Endovascular Aneurysm Repair. (October 2017)
- Main Title:
- A Semiautomated Method for Measuring the 3-Dimensional Fabric to Renal Artery Distances to Determine Endograft Position After Endovascular Aneurysm Repair
- Authors:
- Schuurmann, Richte C. L.
Overeem, Simon P.
Ouriel, Kenneth
Slump, Cornelis H.
Jordan, William D.
Muhs, Bart E.
de Vries, Jean-Paul P. M. - Abstract:
- Purpose: To report a methodology for 3-dimensional (3D) assessment of the stent-graft deployment accuracy after endovascular aneurysm repair (EVAR).Methods: A methodology was developed and validated to calculate the 3D distances between the endograft fabric and the renal arteries over the curve of the aorta. The shortest distance between one of the renal arteries and the fabric (SFD) and the distance from the contralateral renal artery to the fabric (CFD) were determined on the first postoperative computed tomography (CT) scan of 81 elective EVAR patients. The SFDs were subdivided into a target position (0–3 mm distal to the renal artery), high position (partially covering the renal artery), and low position (>3 mm distal to the renal artery). Data are reported as the median (interquartile range, IQR).Results: Intra- and interobserver agreements for automatic and manual calculation of the SFD and CFD were excellent (ICC >0.892, p<0.001). The median SFD was 1.4 mm (IQR −0.9, 3.0) and the median CFD was 8.0 mm (IQR 3.9, 14.2). The target position was achieved in 44%, high position in 30%, and low position in 26% of the patients. The median slope of the endograft toward the higher renal artery was 2.5° (IQR −5.5°, 13.9°).Conclusion: The novel methodology using 3D CT reconstructions enables accurate evaluation of endograft position and slope within the proximal aortic neck. In this series, only 44% of endografts were placed within the target position with regard to the lowermostPurpose: To report a methodology for 3-dimensional (3D) assessment of the stent-graft deployment accuracy after endovascular aneurysm repair (EVAR).Methods: A methodology was developed and validated to calculate the 3D distances between the endograft fabric and the renal arteries over the curve of the aorta. The shortest distance between one of the renal arteries and the fabric (SFD) and the distance from the contralateral renal artery to the fabric (CFD) were determined on the first postoperative computed tomography (CT) scan of 81 elective EVAR patients. The SFDs were subdivided into a target position (0–3 mm distal to the renal artery), high position (partially covering the renal artery), and low position (>3 mm distal to the renal artery). Data are reported as the median (interquartile range, IQR).Results: Intra- and interobserver agreements for automatic and manual calculation of the SFD and CFD were excellent (ICC >0.892, p<0.001). The median SFD was 1.4 mm (IQR −0.9, 3.0) and the median CFD was 8.0 mm (IQR 3.9, 14.2). The target position was achieved in 44%, high position in 30%, and low position in 26% of the patients. The median slope of the endograft toward the higher renal artery was 2.5° (IQR −5.5°, 13.9°).Conclusion: The novel methodology using 3D CT reconstructions enables accurate evaluation of endograft position and slope within the proximal aortic neck. In this series, only 44% of endografts were placed within the target position with regard to the lowermost renal artery. … (more)
- Is Part Of:
- Journal of endovascular therapy. Volume 24:Number 5(2017:Oct.)
- Journal:
- Journal of endovascular therapy
- Issue:
- Volume 24:Number 5(2017:Oct.)
- Issue Display:
- Volume 24, Issue 5 (2017)
- Year:
- 2017
- Volume:
- 24
- Issue:
- 5
- Issue Sort Value:
- 2017-0024-0005-0000
- Page Start:
- 698
- Page End:
- 706
- Publication Date:
- 2017-10
- Subjects:
- 3D reconstructions -- abdominal aortic aneurysm -- aneurysm neck -- computed tomography -- deployment technique -- endograft -- endovascular aneurysm repair -- geometry -- imaging -- renal artery -- stent-graft
Blood-vessels -- Endoscopic surgery -- Periodicals
Angioscopy -- Periodicals
Intravenous catheterization -- Periodicals
Peripheral vascular diseases -- Treatment -- Periodicals
Vascular Surgical Procedures -- Periodicals
Angioscopy -- Periodicals
Catheterization, Peripheral -- Periodicals
Peripheral Vascular Diseases -- therapy -- Periodicals
Angioscopie
Maladies vasculaires périphériques
617.413 - Journal URLs:
- http://jet.sagepub.com/ ↗
http://www.jevt.org ↗
http://www.uk.sagepub.com ↗ - DOI:
- 10.1177/1526602817719882 ↗
- Languages:
- English
- ISSNs:
- 1526-6028
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 7680.xml