Comparison between Nageotte and flow cytometric counting of residual leucocytes in freshly prepared leucocyte-reduced red blood cell components. Issue 4 (August 2018)
- Record Type:
- Journal Article
- Title:
- Comparison between Nageotte and flow cytometric counting of residual leucocytes in freshly prepared leucocyte-reduced red blood cell components. Issue 4 (August 2018)
- Main Title:
- Comparison between Nageotte and flow cytometric counting of residual leucocytes in freshly prepared leucocyte-reduced red blood cell components
- Authors:
- Kyriakou, Elias
Nearchakos, Nikolaos
Bonovas, Stefanos
Makri, Efstathia
Pantavou, Katerina
Nikolopoulos, Georgios K.
Kottaridi, Christine
Gialeraki, Argyri
Douramani, Panagiota
Taichert, Maria
Kapsimali, Violetta
Tsantes, Argirios E. - Abstract:
- Abstract: Background: Flow cytometry (FC) and Nageotte hemocytometry represent the most widely accepted methods for counting residual white blood cells (rWBCs) in leucocyte-reduced (LR) blood components. Our aim was to study the agreement between the two methods, under real working blood bank conditions. Materials and methods: 94 freshly produced LR red blood cell (RBC) units were tested for rWBC concentrations by FC and Nageotte. To assess the precision of each method, we calculated the intra-assay coefficients of variation (CV), and followed the Bland-Altman methodology to study the agreement between the two methods. Results: CV was 18.5% and 26.2% for the Nageotte and the FC, respectively. However, the agreement between the duplicate observations, using the binary cut-off threshold of 1 × 10 6 WBCs per unit to define the results as "pass/fail", was 71.9% for the Nageotte and 93.3% for the FC. Linear regression analysis did not show any correlation (R-squared = 0.01, p = 0.35) between the two methods, while the Bland-Altman analysis for the measuring agreement showed a bias toward a higher Nageotte count of 0.77 × 10 6 leucocytes per unit (p < 0.001) with the 95% limits of agreement (d ± 2 sd) ranging from –0.40 × 10 6 to 1.94 × 10 6 leucocytes per unit. Conclusion: The absence of agreement between Nageotte and FC method, with the differences within d ± 2 sd being of high clinical importance, suggests that the two methods cannot be used for clinical purposesAbstract: Background: Flow cytometry (FC) and Nageotte hemocytometry represent the most widely accepted methods for counting residual white blood cells (rWBCs) in leucocyte-reduced (LR) blood components. Our aim was to study the agreement between the two methods, under real working blood bank conditions. Materials and methods: 94 freshly produced LR red blood cell (RBC) units were tested for rWBC concentrations by FC and Nageotte. To assess the precision of each method, we calculated the intra-assay coefficients of variation (CV), and followed the Bland-Altman methodology to study the agreement between the two methods. Results: CV was 18.5% and 26.2% for the Nageotte and the FC, respectively. However, the agreement between the duplicate observations, using the binary cut-off threshold of 1 × 10 6 WBCs per unit to define the results as "pass/fail", was 71.9% for the Nageotte and 93.3% for the FC. Linear regression analysis did not show any correlation (R-squared = 0.01, p = 0.35) between the two methods, while the Bland-Altman analysis for the measuring agreement showed a bias toward a higher Nageotte count of 0.77 × 10 6 leucocytes per unit (p < 0.001) with the 95% limits of agreement (d ± 2 sd) ranging from –0.40 × 10 6 to 1.94 × 10 6 leucocytes per unit. Conclusion: The absence of agreement between Nageotte and FC method, with the differences within d ± 2 sd being of high clinical importance, suggests that the two methods cannot be used for clinical purposes interchangeably. The Nageotte seems unsuitable for quality control even with a pass-fail criterion, under real working blood bank conditions. … (more)
- Is Part Of:
- Transfusion and apheresis science. Volume 57:Issue 4(2018)
- Journal:
- Transfusion and apheresis science
- Issue:
- Volume 57:Issue 4(2018)
- Issue Display:
- Volume 57, Issue 4 (2018)
- Year:
- 2018
- Volume:
- 57
- Issue:
- 4
- Issue Sort Value:
- 2018-0057-0004-0000
- Page Start:
- 544
- Page End:
- 548
- Publication Date:
- 2018-08
- Subjects:
- Leukoreduction -- Nageotte -- Flow cytometry -- Leucocyte counting -- Red blood cell unit
Blood -- Transfusion -- Periodicals
Hemapheresis -- Periodicals
615.39 - Journal URLs:
- http://www.sciencedirect.com/science/journal/14730502 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/14730502 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/14730502 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.transci.2018.06.002 ↗
- Languages:
- English
- ISSNs:
- 1473-0502
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 9020.704500
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 7698.xml