- Abstract:
- Abstract : Although intraoperative damage to nerve roots it's not as catastrophic as spinal cord injuries, damage to these structures could produce motor and sensory deficit, neuropathic pain, bladder and bowel dysfunction. Free-running EMG is considered a standard method for root monitoring given its ability to detect, in real time, trains or bursts of abnormal discharges that indicate possible ventral root damage. It's easy to use, not affected by anesthesia and has high sensitivity but low specificity. Given the myotomal overlapping multichannel recordings are required using preferably bipolar intramuscular electrodes. Triggered electromyography (tEMG) allows the surgeon to map viable neural tissue and to detect the proximity of instrumentation to nerve roots. tEMG has also been used as guidance during selective dorsal rhizotomy and it helps in the safe placement of pedicle screws. Bipolar stimulation is more selective and allows better spatial discrimination, a threshold higher than 6–8 mA (using a pulse duration of 0.1 ms) indicates very likely absence of functional tissue. Both methods have important limitations and should not be used alone but as a part of a multimodality monitoring plan including also somatosensory evoked potentials, transcranial electrical motor evoked potentials, H and sacral reflexes.
- Is Part Of:
- Clinical neurophysiology. Volume 127:Issue 9(2016:Sep.)
- Journal:
- Clinical neurophysiology
- Issue:
- Volume 127:Issue 9(2016:Sep.)
- Issue Display:
- Volume 127, Issue 9 (2016)
- Year:
- 2016
- Volume:
- 127
- Issue:
- 9
- Issue Sort Value:
- 2016-0127-0009-0000
- Page Start:
- e309
- Page End:
- Publication Date:
- 2016-09
- Subjects:
- Neurophysiology -- Periodicals
Electroencephalography -- Periodicals
Electromyography -- Periodicals
Neurology -- Periodicals
612.8 - Journal URLs:
- http://www.sciencedirect.com/science/journal/13882457 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.clinph.2016.05.301 ↗
- Languages:
- English
- ISSNs:
- 1388-2457
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3286.310645
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 7658.xml