Vacuum-assisted breast biopsies (VAB) carried out on an open 1.0 T MR imager: Influence of patient and target characteristics on the procedural and clinical results. Issue 6 (June 2016)
- Record Type:
- Journal Article
- Title:
- Vacuum-assisted breast biopsies (VAB) carried out on an open 1.0 T MR imager: Influence of patient and target characteristics on the procedural and clinical results. Issue 6 (June 2016)
- Main Title:
- Vacuum-assisted breast biopsies (VAB) carried out on an open 1.0 T MR imager: Influence of patient and target characteristics on the procedural and clinical results
- Authors:
- Krug, Barbara
Hellmich, Martin
Ulhaas, Angela
Krämer, Stefan
Rhiem, Kerstin
Zarghooni, Verena
Püsken, Michael
Schwabe, Hendrik
Grinstein, Olga
Markiefka, Birgid
Maintz, David - Abstract:
- Abstract: Purpose: The study was conducted in order to assess the clinical impact of MRI-guided vacuum-assisted breast biopsies carried out using an open 1.0 T open MRI-system. Material and methods: The clinical, imaging, interventional and histological data of all 132 patients with a first MRI-guided vacuum-assisted breast biopsy carried out between 07/2005 and 03/2012 at the Radiological Department were extracted from the clinical files. The clinical outcome of patients with benign histological findings was assessed based on the clinical files and queries of the local gynecologists in charge. In the 103 interventional image data sets available target localization and target size were evaluated by two board-certified senior radiologists. Clinical data, lesion characteristics and interventional results were evaluated statistically using subgroup analyses. Results: 131 of 132 MRI-guided breast biopsies (99.2%) were carried out successfully. The median interventional duration was 30 min (25%-percentile 25 min, 75%-percentile 35 min, maximum 75 min). Minor complications occurred in 12 interventions of the 131 (9.2%). The histological work-up of the biopsy specimen showed benign results in 98 of 131 interventions (74.8%), lesions with uncertain biological potential in 5 biopsies (3.8%) and malignant findings in 28 biopsies (21.4%). There were 2 false negative histological findings. Neither the patient age nor the medical history nor the anticipated risk of developing breastAbstract: Purpose: The study was conducted in order to assess the clinical impact of MRI-guided vacuum-assisted breast biopsies carried out using an open 1.0 T open MRI-system. Material and methods: The clinical, imaging, interventional and histological data of all 132 patients with a first MRI-guided vacuum-assisted breast biopsy carried out between 07/2005 and 03/2012 at the Radiological Department were extracted from the clinical files. The clinical outcome of patients with benign histological findings was assessed based on the clinical files and queries of the local gynecologists in charge. In the 103 interventional image data sets available target localization and target size were evaluated by two board-certified senior radiologists. Clinical data, lesion characteristics and interventional results were evaluated statistically using subgroup analyses. Results: 131 of 132 MRI-guided breast biopsies (99.2%) were carried out successfully. The median interventional duration was 30 min (25%-percentile 25 min, 75%-percentile 35 min, maximum 75 min). Minor complications occurred in 12 interventions of the 131 (9.2%). The histological work-up of the biopsy specimen showed benign results in 98 of 131 interventions (74.8%), lesions with uncertain biological potential in 5 biopsies (3.8%) and malignant findings in 28 biopsies (21.4%). There were 2 false negative histological findings. Neither the patient age nor the medical history nor the anticipated risk of developing breast cancer had an impact on the success rates and the complication rates. In the 103 interventions with available image data sets the maximum target lesion diameters were 1–5 mm in 16 lesions (15.5%), 6–10 mm in 41 lesions (39.8%) and 11–15 mm in 29 lesions (28.2%). There was a positive correlation between the maximum diameters and the rate of malignancy of the target lesions (p = 0.020) as well as a trend towards longer interventional procedure durations in smaller target lesions (p = 0.183). Conclusion: MRI-guided vacuum-assisted breast biopsy for suspicious breast lesions is a clinically safe and feasible method even in small target lesions when using an open high-field MRI-system. … (more)
- Is Part Of:
- European journal of radiology. Volume 85:Issue 6(2016)
- Journal:
- European journal of radiology
- Issue:
- Volume 85:Issue 6(2016)
- Issue Display:
- Volume 85, Issue 6 (2016)
- Year:
- 2016
- Volume:
- 85
- Issue:
- 6
- Issue Sort Value:
- 2016-0085-0006-0000
- Page Start:
- 1157
- Page End:
- 1166
- Publication Date:
- 2016-06
- Subjects:
- Medical radiology -- Periodicals
Radiology -- Periodicals
Radiologie médicale -- Périodiques
Medical radiology
Periodicals
616.075705 - Journal URLs:
- http://www.sciencedirect.com/science/journal/0720048X ↗
http://www.elsevier.com/homepage/elecserv.htt ↗
http://www.clinicalkey.com/dura/browse/journalIssue/0720048X ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/0720048X ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.ejrad.2016.02.030 ↗
- Languages:
- English
- ISSNs:
- 0720-048X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.738050
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 7637.xml