Evaluation of pulmonary nodules and infection on chest CT with radiation dose equivalent to chest radiography: Prospective intra-individual comparison study to standard dose CT. Issue 2 (February 2016)
- Record Type:
- Journal Article
- Title:
- Evaluation of pulmonary nodules and infection on chest CT with radiation dose equivalent to chest radiography: Prospective intra-individual comparison study to standard dose CT. Issue 2 (February 2016)
- Main Title:
- Evaluation of pulmonary nodules and infection on chest CT with radiation dose equivalent to chest radiography: Prospective intra-individual comparison study to standard dose CT
- Authors:
- Martini, K.
Barth, B.K.
Nguyen-Kim, T.D.L.
Baumueller, S.
Alkadhi, H.
Frauenfelder, T. - Abstract:
- Abstract: Purpose: To compare prospectively, in patients undergoing chest computed tomography (CT) for pulmonary-nodules or infection, image-quality and accuracy of standard dose (SD) and reduced dose (RD) CT with tin-filtration. Material and methods: This IRB-approved study included 100 consecutive patients (36 female;median age 56 years) referred for follow-up of pulmonary-nodules ( n = 43) or suspicion of infection ( n = 57) undergoing single-energy CT with SD and RD using tin-filtration at 100 kVp (CTDIvol 2.47 mGy and 0.07 mGy, respectively). Images were reconstructed with advanced modeled iterative reconstruction (ADMIRE) at strength 3 and 5. Image-noise was measured. Two independent readers evaluated nodules and pulmonary-infection. SD CT served as reference standard. Results: No significant difference was found in noise between RD with ADMIRE5 and SD with ADMIRE3 (118HU ± 14 vs. 120HU ± 17; p = 0.08). Sensitivity for detection of atelectasis and interstitial lung changes was higher in images reconstructed with ADMIRE5 (93% and 88%; respectively) than in those reconstructed with ADIMRE3 (77% and 78%; respectively). Sensitivity for detection of consolidations was 90% for ADMIRE3 and 89% for ADMIRE5. Sensitivity for nodule detection was 71% for ADMIRE3 and 81% for ADMIRE5. Specificity for detection of atelectasis and interstitial lung changes was 99% and 96% with ADMIRE5 and 99% and 96% with ADMIRE3. Specificity for detection of consolidations was 99% for ADMIRE3 andAbstract: Purpose: To compare prospectively, in patients undergoing chest computed tomography (CT) for pulmonary-nodules or infection, image-quality and accuracy of standard dose (SD) and reduced dose (RD) CT with tin-filtration. Material and methods: This IRB-approved study included 100 consecutive patients (36 female;median age 56 years) referred for follow-up of pulmonary-nodules ( n = 43) or suspicion of infection ( n = 57) undergoing single-energy CT with SD and RD using tin-filtration at 100 kVp (CTDIvol 2.47 mGy and 0.07 mGy, respectively). Images were reconstructed with advanced modeled iterative reconstruction (ADMIRE) at strength 3 and 5. Image-noise was measured. Two independent readers evaluated nodules and pulmonary-infection. SD CT served as reference standard. Results: No significant difference was found in noise between RD with ADMIRE5 and SD with ADMIRE3 (118HU ± 14 vs. 120HU ± 17; p = 0.08). Sensitivity for detection of atelectasis and interstitial lung changes was higher in images reconstructed with ADMIRE5 (93% and 88%; respectively) than in those reconstructed with ADIMRE3 (77% and 78%; respectively). Sensitivity for detection of consolidations was 90% for ADMIRE3 and 89% for ADMIRE5. Sensitivity for nodule detection was 71% for ADMIRE3 and 81% for ADMIRE5. Specificity for detection of atelectasis and interstitial lung changes was 99% and 96% with ADMIRE5 and 99% and 96% with ADMIRE3. Specificity for detection of consolidations was 99% for ADMIRE3 and 5. Specificity for detection of nodules was 87% for both ADMIRE3 and 5. Conclusion: Chest CT with a radiation dose equivalent to conventional radiography is feasible and allows for detection of pulmonary infection with high sensitivity, whereas the accuracy for detecting nodules is only moderate. … (more)
- Is Part Of:
- European journal of radiology. Volume 85:Issue 2(2016)
- Journal:
- European journal of radiology
- Issue:
- Volume 85:Issue 2(2016)
- Issue Display:
- Volume 85, Issue 2 (2016)
- Year:
- 2016
- Volume:
- 85
- Issue:
- 2
- Issue Sort Value:
- 2016-0085-0002-0000
- Page Start:
- 360
- Page End:
- 365
- Publication Date:
- 2016-02
- Subjects:
- Redused dose protocol -- Lung infection -- Computed tomography -- Tin filtration -- Iterative reconstruction
Medical radiology -- Periodicals
Radiology -- Periodicals
Radiologie médicale -- Périodiques
Medical radiology
Periodicals
616.075705 - Journal URLs:
- http://www.sciencedirect.com/science/journal/0720048X ↗
http://www.elsevier.com/homepage/elecserv.htt ↗
http://www.clinicalkey.com/dura/browse/journalIssue/0720048X ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/0720048X ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.ejrad.2015.11.036 ↗
- Languages:
- English
- ISSNs:
- 0720-048X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.738050
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 7637.xml