Error analysis on measurement temperature by means dual-color thermography technique. (August 2016)
- Record Type:
- Journal Article
- Title:
- Error analysis on measurement temperature by means dual-color thermography technique. (August 2016)
- Main Title:
- Error analysis on measurement temperature by means dual-color thermography technique
- Authors:
- Musto, Marilena
Rotondo, Giuseppe
De Cesare, Mario
Del Vecchio, Antonio
Savino, Luigi
De Filippis, Federico - Abstract:
- Highlights: Experimental investigation by means dual-color thermography technique. The influence of wavelength distance on measurement temperature was reported. Mathematical model has developed to measure temperature by means IR thermo-camera. Novel correlation to estimate temperature measurement error was provided. Dual-color thermography measurement emissivity free. Abstract: Dual color thermography is a non-contact measurement temperature technique used mainly when the emissivity of surface is unknown; it is based on ratio of monochromatic emissive power calculated by means Planck's radiation equation and allows measuring the temperature of gray body surface objects without being assigned their emissivity and without approximations. For real surfaces, the emissivity varies with the temperature of surface as well as the wavelength and the direction of radiation. In this case, the dual color thermometry is executed by equipping the IR camera of two narrow band pass filters, so as to consider the surface emissivity of a quite constant value. This allows calculating the ratio between the radiative fluxes of the two different emission wavelengths that is almost independent to the surface emissivity. One of the crucial factor in this technique is the choice of the two narrow filter wavelengths. In fact the measurement errors depends directly on the two wavelengths and the variation of spectral emissivity related to the wavelength chosen and it also depends inversely on distanceHighlights: Experimental investigation by means dual-color thermography technique. The influence of wavelength distance on measurement temperature was reported. Mathematical model has developed to measure temperature by means IR thermo-camera. Novel correlation to estimate temperature measurement error was provided. Dual-color thermography measurement emissivity free. Abstract: Dual color thermography is a non-contact measurement temperature technique used mainly when the emissivity of surface is unknown; it is based on ratio of monochromatic emissive power calculated by means Planck's radiation equation and allows measuring the temperature of gray body surface objects without being assigned their emissivity and without approximations. For real surfaces, the emissivity varies with the temperature of surface as well as the wavelength and the direction of radiation. In this case, the dual color thermometry is executed by equipping the IR camera of two narrow band pass filters, so as to consider the surface emissivity of a quite constant value. This allows calculating the ratio between the radiative fluxes of the two different emission wavelengths that is almost independent to the surface emissivity. One of the crucial factor in this technique is the choice of the two narrow filter wavelengths. In fact the measurement errors depends directly on the two wavelengths and the variation of spectral emissivity related to the wavelength chosen and it also depends inversely on distance between central value of filters. In this paper, the authors have developed and validated a mathematical model of experimental setup to measure object surface temperature by means IR thermo-camera. This mathematical model was used to quantify the temperature measurement error in the dual-color technique. A novel correlation to estimate temperature measurement error was provided. … (more)
- Is Part Of:
- Measurement. Volume 90(2016)
- Journal:
- Measurement
- Issue:
- Volume 90(2016)
- Issue Display:
- Volume 90, Issue 2016 (2016)
- Year:
- 2016
- Volume:
- 90
- Issue:
- 2016
- Issue Sort Value:
- 2016-0090-2016-0000
- Page Start:
- 265
- Page End:
- 277
- Publication Date:
- 2016-08
- Subjects:
- Thermography -- Emissivity -- Dual color IR -- Temperature measurement
Weights and measures -- Periodicals
Measurement -- Periodicals
Measurement
Weights and measures
Periodicals
530.8 - Journal URLs:
- http://www.sciencedirect.com/science/journal/02632241 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.measurement.2016.04.024 ↗
- Languages:
- English
- ISSNs:
- 0263-2241
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5413.544700
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 7630.xml