Experimental study on functionality of surfactant solution in turbulent heat transfer by varying local shear rate. (November 2016)
- Record Type:
- Journal Article
- Title:
- Experimental study on functionality of surfactant solution in turbulent heat transfer by varying local shear rate. (November 2016)
- Main Title:
- Experimental study on functionality of surfactant solution in turbulent heat transfer by varying local shear rate
- Authors:
- Tsukahara, Takahiro
Hara, Shumpei
Kawada, Shoko
Kawaguchi, Yasuo - Abstract:
- Highlights: Drag-reducing CTAC solution flows on heating plate was experimentally studied. Fluid functionality depends on temperature, local shear rate, and CTAC concentration. Destruction and recovery conditions of micellar-network structures were estimated. We used effective structural number of micelles to link HTR to fluid flow condition. Minimum structural number for functionality was proposed as percolation threshold. Abstract: Inhibiting turbulence by adding a surfactant may simultaneously induce a heat-transfer reduction as well as a drag reduction. Those reductions are attributed to micellar network structures (MNS) that form in the surfactant solution under suitable conditions in terms of temperature, concentration, and shear rate. Fluid functionalities of such a fluid with respect to mass and heat transfers are still unclear, in particular, for complex geometries accompanied by locally-enhanced shear rates. We carried out experiments under various conditions of fluid flow and liquid states in terms of temperatures and concentrations of the solution with a view to identify the factors affecting surfactant solution flow. To estimate the influence of a local shear rate on relevant bulk flow of a surfactant solution, we installed an orifice in a two-dimensional channel and measured the variations of the local heat-transfer coefficient downstream of the orifice. When passed through the orifice, the flow should be accompanied by strong shear layers separating from theHighlights: Drag-reducing CTAC solution flows on heating plate was experimentally studied. Fluid functionality depends on temperature, local shear rate, and CTAC concentration. Destruction and recovery conditions of micellar-network structures were estimated. We used effective structural number of micelles to link HTR to fluid flow condition. Minimum structural number for functionality was proposed as percolation threshold. Abstract: Inhibiting turbulence by adding a surfactant may simultaneously induce a heat-transfer reduction as well as a drag reduction. Those reductions are attributed to micellar network structures (MNS) that form in the surfactant solution under suitable conditions in terms of temperature, concentration, and shear rate. Fluid functionalities of such a fluid with respect to mass and heat transfers are still unclear, in particular, for complex geometries accompanied by locally-enhanced shear rates. We carried out experiments under various conditions of fluid flow and liquid states in terms of temperatures and concentrations of the solution with a view to identify the factors affecting surfactant solution flow. To estimate the influence of a local shear rate on relevant bulk flow of a surfactant solution, we installed an orifice in a two-dimensional channel and measured the variations of the local heat-transfer coefficient downstream of the orifice. When passed through the orifice, the flow should be accompanied by strong shear layers separating from the orifice edges. Hence, the orifice associated with locally-enhanced shear rate gave rise to a degradation of the heat transfer reducing effect at lower Reynolds numbers because of catastrophic destruction of the large-scale micellar network. This degradation was limited just behind orifice maybe due to the ability of the micellar network to self-repair. The effective structural number, representing the amount of networking micelles, was introduced to describe the relationship between the magnitude of the heat transfer reductions and the fluid flow conditions including the local shear rate, the surfactant concentration, and the temperature. We interpreted the catastrophic destruction of the large-scale micellar network structure from the aspect of the percolation theory. The orifice installation provided the possibility of controlling fluid functionality by the adoption of the combined effect of the concentration or temperature of the solution. … (more)
- Is Part Of:
- International journal of heat and mass transfer. Volume 102(2016:Nov.)
- Journal:
- International journal of heat and mass transfer
- Issue:
- Volume 102(2016:Nov.)
- Issue Display:
- Volume 102 (2016)
- Year:
- 2016
- Volume:
- 102
- Issue Sort Value:
- 2016-0102-0000-0000
- Page Start:
- 360
- Page End:
- 368
- Publication Date:
- 2016-11
- Subjects:
- Viscoelasticity -- Drag reduction -- Turbulent flow -- Heat transfer -- Surfactant solution
Heat -- Transmission -- Periodicals
Mass transfer -- Periodicals
Chaleur -- Transmission -- Périodiques
Transfert de masse -- Périodiques
Electronic journals
621.4022 - Journal URLs:
- http://www.sciencedirect.com/science/journal/00179310 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.ijheatmasstransfer.2016.06.024 ↗
- Languages:
- English
- ISSNs:
- 0017-9310
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4542.280000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 7634.xml