Prêtre, René - Abstract:
- Background: Permanent pacemaker implantation after surgical aortic valve replacement depends on patient selection and risk factors for conduction disorders. We aimed to identify risk criteria and obtain a selected group comparable to patients assigned to transcatheter aortic valve implantation. Methods: Isolated sutured aortic valve replacements in 994 patients treated from 2007 to 2015 were reviewed. Demographics, hospital stay, preexisting conduction disorders, surgical technique, and etiology in patients with and without permanent pacemaker implantation were compared. Reported outcomes after transcatheter aortic valve implantation were compared with those of a subgroup including only degenerative valve disease and first redo. Results: The incidence of permanent pacemaker implantation was 2.9%. Longer hospital stay ( p = 0.01), preexisting rhythm disorders ( p < 0.001), complex prosthetic endocarditis ( p = 0.01), and complex redo ( p < 0.001) were associated with permanent pacemaker implantation. Although prostheses were sutured with continuous monofilament in the majority of cases (86%), interrupted pledgetted sutures were used more often in the pacemaker group ( p = 0.002). In the subgroup analysis, the incidence of permanent pacemaker implantation was 2%; preexisting rhythm disorders and the suture technique were still major risk factors. Conclusion: Permanent pacemaker implantation depends on etiology, preexisting rhythm disorders, and suture technique, and theBackground: Permanent pacemaker implantation after surgical aortic valve replacement depends on patient selection and risk factors for conduction disorders. We aimed to identify risk criteria and obtain a selected group comparable to patients assigned to transcatheter aortic valve implantation. Methods: Isolated sutured aortic valve replacements in 994 patients treated from 2007 to 2015 were reviewed. Demographics, hospital stay, preexisting conduction disorders, surgical technique, and etiology in patients with and without permanent pacemaker implantation were compared. Reported outcomes after transcatheter aortic valve implantation were compared with those of a subgroup including only degenerative valve disease and first redo. Results: The incidence of permanent pacemaker implantation was 2.9%. Longer hospital stay ( p = 0.01), preexisting rhythm disorders ( p < 0.001), complex prosthetic endocarditis ( p = 0.01), and complex redo ( p < 0.001) were associated with permanent pacemaker implantation. Although prostheses were sutured with continuous monofilament in the majority of cases (86%), interrupted pledgetted sutures were used more often in the pacemaker group ( p = 0.002). In the subgroup analysis, the incidence of permanent pacemaker implantation was 2%; preexisting rhythm disorders and the suture technique were still major risk factors. Conclusion: Permanent pacemaker implantation depends on etiology, preexisting rhythm disorders, and suture technique, and the 2% incidence compares favorably with the reported 5- to 10-fold higher incidence after transcatheter aortic valve implantation. Cost analysis should take this into account. Often dismissed as minor complication, permanent pacemaker implantation increases the risks of endocarditis, impaired myocardial recovery, and higher mortality if associated with prosthesis regurgitation. … (more)
- Is Part Of:
- Asian cardiovascular & thoracic annals. Volume 25:Number 5(2017)
- Journal:
- Asian cardiovascular & thoracic annals
- Issue:
- Volume 25:Number 5(2017)
- Issue Display:
- Volume 25, Issue 5 (2017)
- Year:
- 2017
- Volume:
- 25
- Issue:
- 5
- Issue Sort Value:
- 2017-0025-0005-0000
- Page Start:
- 350
- Page End:
- 356
- Publication Date:
- 2017-06
- Subjects:
- Aortic valve -- Arrhythmias -- cardiac -- Atrioventricular block -- Heart valve prosthesis implantation -- Pacemaker -- artificial -- Suture techniques
Heart -- Diseases -- Asia -- Periodicals
Heart -- Diseases -- Pacific Area -- Periodicals
Heart -- Diseases -- Periodicals
Heart -- Surgery -- Asia -- Periodicals
Heart -- Surgery -- Pacific Area -- Periodicals
Heart -- Surgery -- Periodicals
Chest -- Surgery -- Asia -- Periodicals
Chest -- Surgery -- Pacific Area -- Periodicals
Chest -- Surgery -- Periodicals
617.412 - Journal URLs:
- http://aan.sagepub.com ↗
http://asianannals.ctsnetjournals.org ↗
http://www.uk.sagepub.com ↗ - DOI:
- 10.1177/0218492317712309 ↗
- Languages:
- English
- ISSNs:
- 0218-4923
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 7617.xml