Interventional Therapy for Transplant Renal Artery Stenosis Is Safe and Effective in Preserving Allograft Function and Improving Hypertension. (January 2017)
- Record Type:
- Journal Article
- Title:
- Interventional Therapy for Transplant Renal Artery Stenosis Is Safe and Effective in Preserving Allograft Function and Improving Hypertension. (January 2017)
- Main Title:
- Interventional Therapy for Transplant Renal Artery Stenosis Is Safe and Effective in Preserving Allograft Function and Improving Hypertension
- Authors:
- Wang, Lili
Liu, Bin
Yan, Jieke
Wang, Yongzheng
Wang, Wujie
Wang, Wei
Chang, Haiyang
Wang, Hongwei
Wang, Changjun
Li, Zheng
Li, Yuliang - Abstract:
- Purpose: To evaluate the outcomes of percutaneous intervention (PI) for transplant renal artery stenosis (TRAS). Materials and Methods: Doppler ultrasonography was used as the screening tool, and angiography was the diagnostic method for TRAS. The indications for PI were (1) a reduction in lumen diameter of >50% or (2) a mean pressure gradient of >15 mm Hg. Technical success was assessed immediately after the procedure. The short-term results of stenosis were evaluated by serum creatinine (Scr) levels and blood pressure (BP). The long-term results were assessed by graft survival and renal function. Results: From October 2009 to July 2015, a total of 660 patients had kidney transplantation and 22 cases underwent PI. The technical success was 100%. The mean Scr level preintervention was 321.6 ± 167.2 (range, 171.3-862.0) μmol/L, and it decreased to 145.3 ± 44.7 (range, 74.3-260.8) μmol/L 1 month postintervention ( P < .001). Blood pressure was also improved at 1 month postintervention, as assessed by systolic (157.0 ± 13.0 vs 131.0 ± 11.0 mm Hg, P < .001), diastolic (95.0 ± 5.0 vs 77.0 ± 9.0 mm Hg, P < .001), and mean arterial pressure (116.0 ± 7.0 vs 95.0 ± 9.0 mm Hg, P < .001). The patency rate was 100%, 91.7%, and 85.7% at 1, 3, and 12 months, respectively. The secondary patency rate was 100%. Graft survival was 100% during follow-up. There was no significant deterioration in graft function or BP ( P > .05) postintervention when compared to posttransplantation. Conclusions:Purpose: To evaluate the outcomes of percutaneous intervention (PI) for transplant renal artery stenosis (TRAS). Materials and Methods: Doppler ultrasonography was used as the screening tool, and angiography was the diagnostic method for TRAS. The indications for PI were (1) a reduction in lumen diameter of >50% or (2) a mean pressure gradient of >15 mm Hg. Technical success was assessed immediately after the procedure. The short-term results of stenosis were evaluated by serum creatinine (Scr) levels and blood pressure (BP). The long-term results were assessed by graft survival and renal function. Results: From October 2009 to July 2015, a total of 660 patients had kidney transplantation and 22 cases underwent PI. The technical success was 100%. The mean Scr level preintervention was 321.6 ± 167.2 (range, 171.3-862.0) μmol/L, and it decreased to 145.3 ± 44.7 (range, 74.3-260.8) μmol/L 1 month postintervention ( P < .001). Blood pressure was also improved at 1 month postintervention, as assessed by systolic (157.0 ± 13.0 vs 131.0 ± 11.0 mm Hg, P < .001), diastolic (95.0 ± 5.0 vs 77.0 ± 9.0 mm Hg, P < .001), and mean arterial pressure (116.0 ± 7.0 vs 95.0 ± 9.0 mm Hg, P < .001). The patency rate was 100%, 91.7%, and 85.7% at 1, 3, and 12 months, respectively. The secondary patency rate was 100%. Graft survival was 100% during follow-up. There was no significant deterioration in graft function or BP ( P > .05) postintervention when compared to posttransplantation. Conclusions: Percutaneous intervention for TRAS is safe and results in significant improvement both in allograft function and in BP. … (more)
- Is Part Of:
- Vascular & endovascular surgery. Volume 51:Number 1(2017)
- Journal:
- Vascular & endovascular surgery
- Issue:
- Volume 51:Number 1(2017)
- Issue Display:
- Volume 51, Issue 1 (2017)
- Year:
- 2017
- Volume:
- 51
- Issue:
- 1
- Issue Sort Value:
- 2017-0051-0001-0000
- Page Start:
- 4
- Page End:
- 11
- Publication Date:
- 2017-01
- Subjects:
- transplant renal artery stenosis -- hypertension -- renal dysfunction -- percutaneous transluminal angioplasty -- stent implantation
Blood-vessels -- Surgery -- Periodicals
Blood-vessels -- Endoscopic surgery -- Periodicals
Vascular Surgical Procedures -- Periodicals
Angioplasty -- Periodicals
Surgical Procedures, Minimally Invasive -- Periodicals
Vascular Diseases -- surgery -- Periodicals
Vaisseaux sanguins -- Chirurgie -- Périodiques
Vaisseaux sanguins -- Chirurgie endoscopique -- Périodiques
617.41 - Journal URLs:
- http://galenet.galegroup.com/servlet/HWRC?locIC=lcml_main ↗
http://gateway.ovid.com/ovidweb.cgi?T=JS&MODE=ovid&PAGE=toc&D=ovft&AN=00134449-000000000-00000 ↗
http://journals.sagepub.com/home/ves ↗
http://ves.sagepub.com ↗
http://www.sagepublications.com/ ↗ - DOI:
- 10.1177/1538574416682157 ↗
- Languages:
- English
- ISSNs:
- 1538-5744
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 7609.xml