Radial forces of stents used in thoracic endovascular aortic repair and bare self-expanding nitinol stents measured ex vivo – Rapid rescue for obstruction of the innominate artery using bare self-expanding nitinol stents. (February 2017)
- Record Type:
- Journal Article
- Title:
- Radial forces of stents used in thoracic endovascular aortic repair and bare self-expanding nitinol stents measured ex vivo – Rapid rescue for obstruction of the innominate artery using bare self-expanding nitinol stents. (February 2017)
- Main Title:
- Radial forces of stents used in thoracic endovascular aortic repair and bare self-expanding nitinol stents measured ex vivo – Rapid rescue for obstruction of the innominate artery using bare self-expanding nitinol stents
- Authors:
- Matsumoto, Takuya
Inoue, Kentaro
Tanaka, Shinichi
Aoyagi, Yukihiko
Matsubara, Yutaka
Matsuda, Daisuke
Yoshiya, Keiji
Yoshiga, Ryosuke
Ohkusa, Tomoko
Maehara, Yoshihiko - Abstract:
- Purpose: Our objective was to compare the radial forces of several stents ex vivo to identify stents suitable for rescue of the unexpected coverage of aortic arch branches in thoracic endovascular aortic repair. Methods: We measured the radial forces of two types of self-expanding bare nitinol stents (E-luminexx and Epic) used singly or as double-walled pairs, and of three endoprostheses used in thoracic endovascular aortic repair (TEVAR, Gore c-TAG, Relay, and Valiant) by compressing the stent using an MTS Instron universal testing machine (model #5582). We also examined the compressive effects of the TEVAR endoprostheses and the bare nitinol stents on each other. Results: The radial force was greater in the center than at the edge of each stent. In all stents tested, the radial force decreased incrementally with increasing stent diameter. The radial force at the center was two times greater when using two stents than with a single stent. In the compression test, only E-luminexx used as a pair was not compressed after compressing a Relay endoprosthesis by 12 mm. Conclusion: Two E-luminexx stents are appropriate to restore the blood flow if a TEVAR endoprosthesis covers the innominate artery following innominate–carotid–left subclavian arterial bypass.
- Is Part Of:
- Vascular. Volume 25:Number 1(2017)
- Journal:
- Vascular
- Issue:
- Volume 25:Number 1(2017)
- Issue Display:
- Volume 25, Issue 1 (2017)
- Year:
- 2017
- Volume:
- 25
- Issue:
- 1
- Issue Sort Value:
- 2017-0025-0001-0000
- Page Start:
- 36
- Page End:
- 41
- Publication Date:
- 2017-02
- Subjects:
- Radial force measurement -- TEVAR endoprostheses -- self-expanding bare nitinol stents
616.13 - Journal URLs:
- http://vascular.rsmjournals.com/ ↗
http://www.uk.sagepub.com/home.nav ↗ - DOI:
- 10.1177/1708538116640131 ↗
- Languages:
- English
- ISSNs:
- 1708-5381
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 7610.xml